Weidmuller
7940015595
1 / 2
Description
Signal converter/insulator, Configurable for 4 ranges , 0...20 mA or 0...11 V- Part Number
- 7940015595
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
General Data
- Cut-off frequency (-3 dB)
- 5 Hz
- Data backup
- ≥ 100 years (without power supply)
- Humidity
- 0...90 % (no condensation)
- Input/Output
- without analogue/alarm output
- Linearity
- < 0.05 %
- Long-term drift
- 0.1 % / 10.000 h
- Power consumption
- 6 W @ 24 V DC
- Step response time
- < 220 ms (10...90 %)
- Switching current
- Channel 3/4: 3 A @ 240 V AC / 24 V DC (resistive load)
- Transmit function
- direct or inverted
- Type of connection
- Screw connection
- Voltage supply
- 24 V DC ± 10 %
- Weight
- 383 g
Approvals
- Approvals
- CE, CULUS
- ROHS
- Conform
- UL File Number Search
- E205105
Display
- Display range
- -9999...9999
- Display value
- Percentage or real value display
- Scaling
- Variable
- Type
- 4-digit, red LED, 14.2 mmVoltage input/ current input
Dimensions And Weights
- Length
- 137 mm
- Length (inches)
- 5.394 inch
- Width
- 96.6 mm
- Width (inches)
- 3.803 inch
- Height
- 48.8 mm
- Height (inches)
- 1.921 inch
- Weight
- 383 g
- Net weight
- 383 g
Connection Data
- Type of connection
- Screw connection
- Clamping range, rated connection
- 1.5 mm²
- Clamping range, min.
- 0.5 mm²
- Clamping range, max.
- 2.5 mm²
Alarm
- Number of channels, alarm
- 4
- Rated switching current
- 200 mA
- Rated switching voltage
- 50 V DC
- Switching current
- Channel 3/4: 3 A @ 240 V AC / 24 V DC (resistive load)
- Type
- Channel 1/2: transistor outputchannel 3/4: relay contact (CO)
Input
- Attenuation factor
- 0...99, programmable digital filter
- Input signal
- Configurable for 4 ranges
- Input voltage
- 50 mV to 250 V AC / 3 to 250 V DC
- Sensor supply
- 12 V DC to 25 mA
- Type
- Adjustable frequencies
Classifications
- ETIM 6.0
- EC000677
- ETIM 7.0
- EC000677
- EClass 9.0
- 27-14-31-10
- EClass 9.1
- 27-21-03-01
- EClass 10.0
- 27-14-31-10
- UNSPSC
- 30-21-18-01
Output
- Last resistor, max.
- ≤ 850 Ω (current); ≥ 1MΩ (voltage)
- Output signal
- 0...20 mA or 0...11 V
- Scaling
- Variable
- Transmit function
- direct or inverted
- Type
- RO/AO version with 1 analogue output and 2 alarm outputs
Environmental Product Compliance
- REACH SVHC
- Lead 7439-92-1
Functions
- Step response time
- < 220 ms (10...90 %)
Insulation Coordination
- EMC standards
- DIN EN 61326
- Impulse withstand voltage
- 4 kV (1.2/50 µs)
Temperatures
- Humidity
- 0...90 % (no condensation)
- Operating temperature, max.
- 60 °C
- Operating temperature, min.
- 0 °C
- Storage temperature, max.
- 70 °C
- Storage temperature, min.
- -25 °C
- Operating temperature
- 0 °C...60 °C
- Storage temperature
- -25 °C...70 °C
Ratings Iecex/Atex/Cul
- Certificate no. (cULus)
- E205105
Other Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther