Weidmuller
8516560000
WAS2 CMR 1/5/10A AC...
- Part Number
- 8516560000
Free Shipping!
1
Payment methods:
- Best offer from:
- Trusted Automa.Net Supplier
- Availability:
- 0 pcs.On Request
- Warranty:
- 12 months
- Estimated Delivery:
- On Request
- Condition:
- New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original packaging, factory sealed.
Additional Information
- Part Number
- 8516560000
General Data
- Configuration
- DIP switch, Potentiometer
- Current consumption
- 8.3 mA (relay not triggered)/ 24 mA (relay triggered)
- Current-carrying capacity of cross-connect.
- ≤ 2 A
- Galvanic isolation
- 3-way isolator
- Input/Output
- 1/ 5/ 10 A AC / relay
- Power consumption
- ≤ 0.8 W
- Rail
- TS 35
- Step response time
- typ. 700 ms
- Temperature coefficient
- ≤ 800 ppm/K
- Voltage supply
- 24 V DC ± 10 %
Probability Of Failure
- MTTF
- 787 Years
Approvals
- Approvals
- CE, CULUS, EAC
- ROHS
- Conform
- UL File Number Search
- E141197
Dimensions And Weights
- Length
- 92.4 mm
- Length (inches)
- 3.638 inch
- Width
- 22.5 mm
- Width (inches)
- 0.886 inch
- Depth
- 112.4 mm
- Depth (inches)
- 4.425 inch
- Weight
- 150 g
- Net weight
- 116.9 g
Output (Digital)
- Hysteresis
- 5 % or 10 % of threshold value
- Max. switching voltage, DC
- 60 V
- Max. switching voltage, AC
- 250 V
- Continuous current
- 3 A
Connection Data
- Wire connection method
- Screw connection
- Type of connection
- Screw connection
- Clamping range, rated connection
- 2.5 mm²
- Clamping range, min.
- 0.5 mm²
- Clamping range, max.
- 2.5 mm²
Tender Specification Sheets
- Long specification
- Limit-value monitoring component for AC currents up to 10A with relay outputand electrical isolationlimit-value monitoring component in 22.5 mm width for recording 50/ 60 Hz ACcurrents 0...1 A / 0...5 A / 0...10 A. A relay contact (CO)with a switching capacity of 750 VA is available on the output side.Input range can be selected using DIP switches. Switching threshold is adjustable between 10...90 % using the potentiometer on the front side. The 24 VDC power is supplied over the input circuit.The input and outputs are designed with 4 kV of electrical isolation.Add-on housing for TS35 rail mountingDimensions: L/W/H 92.4/ 22.5/ 112.4 mmScrew connection / Nominal cross-section 2.5 mm2Protection degree: IP 20 Input 0...1 A / 0...5 A / 0...10 A AC switchable 50 / 60 Hz // transformer basedVoltage of measuring circuit 250 V ACOutput Relay / COSwitching current 3 ASwitching voltage 6... 250 V AC / 6...60 V DCSwitching threshold 10...90 % via potentiometerHysteresis 5 % or 10 % . Temperature coefficient < 800 ppm KStep response time typ. 700 msAuxiliary power 24 VDC +/- 10 % via output circuitAmbient temperature range 0 °C...+50 °C Secure isolation EN 50178, 2-way isolation up to 4 kVTest voltage 4 kVeff / 5s input against outputRated voltage 300 V AC/DC at overvoltage category III and pollution degree 2Approvals cULusType WAS2 CMR 1/5/10A ac
- Short specification
- Limit-value monitoring component for AC currents up to 10A with relay output and electrical isolationlimit-value monitoring component in 22.5 mm width for recording 50/ 60 Hz AC currents 0...1 A / 0...5 A / 0...10 A. A relay contact (CO) with a switching capacity of 750 VA is available on the output side. Input range can be selected using DIP switches. Switching threshold adjustable between 10...90 % using the front-side potentiometer. The 24 VDC power is supplied over the input circuit. The input and output have 4 kV of electrical isolation.
Input
- Number of inputs
- 1
- Input current
- 0...1 A AC/ 0...5 A AC/ 0...10 A AC
- Input frequency
- 50...60Hz
Classifications
- ETIM 6.0
- EC002653
- ETIM 7.0
- EC002653
- EClass 9.0
- 27-21-01-20
- EClass 9.1
- 27-21-01-20
- EClass 10.0
- 27-21-01-20
- UNSPSC
- 30-21-18-01
Output
- Number of outputs
- 1
- Contact assembly
- 1 CO contact
- Switching thresholds
- Adjustable 10...100% with front potentiometer
- Status indicator
- Green LED
Product Information
- Product information
- This product will soon be replaced by a new product.Please do not use with new systems. Please contact our technical support.
Environmental Product Compliance
- REACH SVHC
- Lead 7439-92-1
Insulation Coordination
- Clearance & creepage distances
- ≥ 3 mm
- EMC standards
- EN 55011, EN 61000-6
- Galvanic isolation
- 3-way isolator
- Impulse withstand voltage
- 4 kV
- Insulation voltage
- 4 kVeff / 5 s
- Pollution severity
- 2
- Rated voltage
- 300 V
- Surge voltage category
- III
Temperatures
- Operating temperature, max.
- 50 °C
- Operating temperature, min.
- 0 °C
- Storage temperature, max.
- 70 °C
- Storage temperature, min.
- -20 °C
- Operating temperature
- 0 °C...50 °C
- Storage temperature
- -20 °C...70 °C
Ratings Iecex/Atex/Cul
- Certificate no. (cULus)
- E141197
Other Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther