Weidmuller

8523400000

WAS1 CMA 1/5/10A AC
8523400000
8523400000
8523400000
8523400000
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Additional Information

Part Number
8523400000

General Data

Accuracy
0.5 % FSR
Configuration
DIP switch
Current consumption
40 mA @ IOUT = 20 mA
Current-carrying capacity of cross-connect.
≤ 2 A
Galvanic isolation
2-way isolator
Input/Output
1/ 5/ 10 A AC / 0(4)...20 mA; 0...10 V
Rail
TS 35
Step response time
typ. 700 ms
Temperature coefficient
≤ 200 ppm/K
Voltage supply
24 V DC ± 10 %

Probability Of Failure

MTTF
533 Years

Approvals

Approvals
CE, CULUS, EAC
ROHS
Conform
UL File Number Search
E141197

Dimensions And Weights

Length
72 mm
Length (inches)
2.835 inch
Width
22.5 mm
Width (inches)
0.886 inch
Depth
92.4 mm
Depth (inches)
3.638 inch
Weight
150 g
Net weight
76.9 g

Connection Data

Wire connection method
Screw connection
Type of connection
Screw connection
Clamping range, rated connection
2.5 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
2.5 mm²

Tender Specification Sheets

Long specification
Monitoring component for AC currents up to 10A with standard signal outputand electrical isolationCurrent monitoring component in 22.5 mm width for recording 50/ 60 Hz AC currents0...1 A / 0...5 A / 0...10 A. Standardised analogue current/voltage signalsare available on the output side. Input and output ranges can be adjusted via DIP switches.The 24 VDC power is supplied over the output circuit.The input and outputs are designed with 6 kV of electrical isolation.Add-on housing for TS35 rail mountingDimensions: L/W/H 72/ 22.5/ 92.4 mmScrew connection / Nominal cross-section 2.5 mm2Protection degree: IP 20   Input                         0...1 A / 0...5 A / 0...10 A AC switchable                                      50 / 60 HzVoltage of measuring circuit 250 V ACOutput                                             0(4)...20 mA / 0...10 VLoad resistance            < 600 Ohm Strom>1 kOhm / voltageTransmission error           < 0,5% v. E. Temperature coefficient 200 ppm / KStep response time typ. 700 msAuxiliary power                                     24 VDC +/- 10 % via output circuitAmbient temperature range 0 °C...+50 °C Secure isolation                   EN 50178, 2-way isolation up to 6 kVTest voltage                               4 kV input against outputRated voltage                                          300 V AC/DC at overvoltage category III and pollution degree 2Approvals cULusType                                                             WAS1 CMA 1/5/10A ac
Short specification
Monitoring component for AC currents up to 10A with standard signal output and electrical isolationCurrent monitoring component in 22.5 mm width for recording 50/ 60 Hz AC currents 0...1 A / 0...5 A / 0...10 A.  Standardised analogue current/voltage signals are available on the output side. Input and output ranges can be adjusted via DIP switches. The 24 VDC power is supplied over the output circuit. The input and outputs are designed with 6 kV of electrical isolation.n>

Input

Number of inputs
1
Input current
0...1 A AC/ 0...5 A AC/ 0...10 A AC
Input frequency
50...60Hz

Classifications

ETIM 6.0
EC002653
ETIM 7.0
EC002653
EClass 9.0
27-21-01-20
EClass 9.1
27-21-01-20
EClass 10.0
27-21-01-20
UNSPSC
30-21-18-01

Output

Number of outputs
1
Output signal limit
Approx. 13 V or 24 mA
Output voltage, note
0...10 V
Output current
0(4)...20 mA
Load impedance voltage
≥ 1 kΩ
Load impedance current
≤ 600 Ω
Offset voltage
max. 0.05 V
Offset current
max. 100 µA
Status indicator
LED ON: OK; LED flashing: signal out of range;LED OFF: Error

Product Information

Product information
This product will soon be replaced by a new product.Please do not use with new systems. Please contact our technical support.

Environmental Product Compliance

REACH SVHC
Lead 7439-92-1

Insulation Coordination

Clearance & creepage distances
≥ 5.5 mm
EMC standards
EN 55011, EN 61000-6
Galvanic isolation
2-way isolator
Impulse withstand voltage
6 kV
Insulation voltage
4 kVeff / 5 s
Pollution severity
2
Rated voltage
300 V
Surge voltage category
III

Temperatures

Operating temperature, max.
50 °C
Operating temperature, min.
0 °C
Storage temperature, max.
70 °C
Storage temperature, min.
-20 °C
Operating temperature
0 °C...50 °C
Storage temperature
-20 °C...70 °C

Ratings Iecex/Atex/Cul

Certificate no. (cULus)
E141197