Weidmuller

8581180000

WAS4 PRO FREQ...
8581180000
Part Number
8581180000
$57.93
net
$60.98
Free Shipping!
1
Payment methods:
Best offer from:
USTrusted Automa.Net Supplier
Availability:
1 pc.
In-Stock
Estimated Delivery:
On Request
Condition:
Used
Used - The item was previously used. The item may have some signs of cosmetic wear, but it is fully operational and functions as intended. The item may be missing the original packaging.
A total of 1 Part In-Stock from 5 Distributors
Delivery from:
CZ
CZ
IT
IT
PL
PL
PT
PT
Shipping Information

Available Offers (5)

8581180000 product image
Weidmuller

8581180000

Condition:
New Factory Sealed
Available:
0 pcs.
On Request
Offer from:
CZTrusted Automa.Net Supplier
Estimated Delivery:
On Request
Warranty:
12 months
1
Free Shipping!
8581180000 product image
Weidmuller

8581180000

Condition:
New Factory Sealed
Available:
0 pcs.
On Request
Offer from:
ITTrusted Automa.Net Supplier
Estimated Delivery:
On Request
Warranty:
12 months
1
Free Shipping!
8581180000 product image
Weidmuller

8581180000

Condition:
New Factory Sealed
Available:
0 pcs.
On Request
Offer from:
ITTrusted Automa.Net Supplier
Estimated Delivery:
On Request
Warranty:
12 months
1
Free Shipping!
8581180000 product image
Weidmuller

8581180000

Condition:
New Factory Sealed
Available:
0 pcs.
On Request
Offer from:
PLTrusted Automa.Net Supplier
Estimated Delivery:
On Request
Warranty:
12 months
1
Free Shipping!
8581180000 product image
Weidmuller

8581180000

Condition:
New Factory Sealed
Available:
0 pcs.
On Request
Offer from:
PTTrusted Automa.Net Supplier
Estimated Delivery:
On Request
Warranty:
12 months
1
Free Shipping!
Offer with manufacturer lead time
Ships in:On Request
Best price:
Send request for price

Additional Information

Part Number
8581180000

General Data

Accuracy
< 0.2% of output range
Configuration
DIP switch (measurement range 0...15900 Hz), Frequency generator (measurement range 0...100 kHz)
Current-carrying capacity of cross-connect.
≤ 2 A
Galvanic isolation
3-way isolator
Input/Output
configurable
Power consumption
max. 1.6 W at IOUT = 20 mA
Rail
TS 35
Step response time
360 ms + 2 times the period time of input frequency
Temperature coefficient
max. 200 ppm/K of output range
Voltage supply
24 V DC ± 25 %

Probability Of Failure

MTTF
458 Years

Approvals

Approvals
CE, CULUS, CULUSEX, EAC
ROHS
Conform
UL File Number Search
E141197

Dimensions And Weights

Length
92.4 mm
Length (inches)
3.638 inch
Width
12.5 mm
Width (inches)
0.492 inch
Depth
112.4 mm
Depth (inches)
4.425 inch
Net weight
118.7 g

Connection Data

Type of connection
Screw connection
Stripping length, rated connection
7 mm
Tightening torque, min.
0.4 Nm
Tightening torque, max.
0.5 Nm
Clamping range, rated connection
2.5 mm²
Clamping range, min.
0.5 mm²
Clamping range, max.
2.5 mm²

Tender Specification Sheets

Long specification
Measurement isolating transformer for frequency signals, configured with DIP switchesf/DC measurement isolating transformer in 12.5 mm width, with external power supply:for transmitting, converting and isolating frequencies up to 100 kHz. Namur or 3-wire NPN/PNP sensors can be connected on the input side.  Standard DC signals 0(4) to 20 mA/ 0 to 10 V are available on the output side.Internal potentiometer is used for zero and span calibrations.Add-on housing for TS35 rail mountingDimensions: L/W/H 92.4/ 12.5/ 112.4 mmScrew connection / Nominal cross-section 2.5 mm2Protection degree: IP 20  Input                         2-, 3-wire PNP/ NPN, Namur initiators, push-pull                                      up to 100 kHz                                                                                                                                                      Output                                             0/4...20 mA                                      0...10 V Load resistance             < 600 Ohm/ Strom/> 1 kOhm/ voltageTransmission error             <0.2 % of inputAuxiliary power                                     24 VDC +/- 25 %Power loss approx. 1.6 WAmbient temperature range 0°C...+55 °CIsolation                                 EN 50178, 3-way isolation up to 4 kV AC/DC of all circuits against each otherTest voltage                               2 kV input against output against auxiliary powerRated voltage                                          300 V AC/DC at overvoltage category III and pollution degree 2Approvals cULus, cULusEXType                                                             WAS4 PRO Freq
Short specification
Measurement isolating transformer for frequency signals, configured with DIP switchesf/DC measurement isolating transformer in 12.5 mm width, with external power supply:for transmitting, converting and isolating frequencies up to 100 kHz. Namur or 3-wire NPN/PNP sensors can be connected on the input side.   Standard DC signals 0(4) to 20 mA/ 0 to 10 V are available on the output side. Internal potentiometer is used for zero and span calibrations.

Input

Number of inputs
1
Sensor
2-, 3-wire PNP/NPN, Namur initiator, push-pull step, Frequency
Sensor supply
16 V DC @ max. 15 mA
Rated input level
Threshold/hysteresis: Namur: approx. 1.7 mA/approx. 0.2 mA; NPN: approx. 6.5 V/approx. 0.2 V; PNP: approx. 6,7 V/approx. 0.5 V
Input frequency
0…100kHz, adjustable

Classifications

ETIM 6.0
EC002918
ETIM 7.0
EC002918
EClass 9.0
27-21-01-28
EClass 9.1
27-21-01-28
EClass 10.0
27-21-01-28

Output

Number of outputs
1
Output voltage, note
0...5 V, 0...10 V, Adjustable
Output current
0...20 mA, 4...20 mA, Adjustable
Load impedance voltage
≥ 1 kΩ
Load impedance current
≤ 600 Ω
Offset voltage
max. 0.05 V
Offset current
max. 100 µA
Status indicator
Green LED

Product Information

Product information
This product will soon be replaced by a new product.Please do not use with new systems. Please contact our technical support.

Environmental Product Compliance

REACH SVHC
Lead 7439-92-1

Insulation Coordination

Clearance & creepage distances
≥ 5.5 mm
EMC standards
EN 55011, EN 61000-6, EN 61326
Galvanic isolation
3-way isolator
Impulse withstand voltage
6 kV
Insulation voltage
4 kVeff / 5 s
Insulation voltage input or output/rail
4 kVeff / 1 min.
Insulation voltage input or output/supply
4 kVeff / 5 s
Pollution severity
2
Rated voltage
300 V
Surge voltage category
III

Temperatures

Operating temperature, max.
55 °C
Operating temperature, min.
0 °C
Storage temperature, max.
85 °C
Storage temperature, min.
-20 °C
Operating temperature
0 °C...55 °C
Storage temperature
-20 °C...85 °C

Ratings Iecex/Atex/Cul

Certificate no. (cULus)
E141197