Weidmuller
8742610000
PAS CMR 0,5...2,5 A DC
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Product Conditions:
Additional Information
- Part Number
- 8742610000
General Data
- Configuration
- none
- Galvanic isolation
- Without isolation
- Rail
- TS 35
Approvals
- Approvals
- CE, CULUS
- ROHS
- Conform
- UL File Number Search
- E141197
Dimensions And Weights
- Length
- 92 mm
- Length (inches)
- 3.622 inch
- Width
- 15.3 mm
- Width (inches)
- 0.602 inch
- Depth
- 95 mm
- Depth (inches)
- 3.74 inch
- Weight
- 70 g
- Net weight
- 69.6 g
Output (Digital)
- Max. switching voltage, DC
- 100 V
- Max. switching voltage, AC
- 100 V
- Continuous current
- 100 mA
- Contact material
- RH/Rd (Reed contact)*
Connection Data
- Type of connection
- Screw connection
- Clamping range, rated connection
- 1.5 mm²
- Clamping range, min.
- 2.5 mm²
- Clamping range, max.
- 2.5 mm²
Tender Specification Sheets
- Long specification
- Limit-value monitoring of DC currents up to 2.5 A with switching outputlimit-value monitoring component for measuring DC currents 0.5... 2.5 A withswitching output. The monitoring unit is designed so that it can be plugged onto the mounting base.Pluggable unit on base, for mounting on TS35 DIN rail Dimensions: L/W/H 92/ 15.3/ 95 mmScrew connection / Nominal cross-section 2.5 mm2Protection degree: IP 20Input 0.5...2.5 A DC / Reed relay coilSwitch-on threshold < 500 mASwitch-off threshold < 50 mAOutput 1 NO / Reed contactSwitching current max 100 mA AC/DCSwitching voltage 100 V AC / 50 V DCAmbient temperature range 0 °C...+55 °C Secure isolation EN 50178, 2-way isolation up to 6 kVTest voltage 4 kVeff / 1 min. input against outputRated voltage 300 V AC/DC at overvoltage category III and pollution degree 2Approvals cULusType PAS CMR 0.5...2.5 A DC
- Short specification
- Limit-value monitoring of DC currents up to 2.5 A with switching outputlimit-value monitoring component for measuring DC currents 0.5... 2.5 A withswitching output. The monitoring unit is designed so that it can be plugged onto the mounting base.
Input
- Input current
- 0.5...2.5 A DC
- Input resistance, current
- < 50 mΩ
- Pulse duration
- min. 1 ms
Classifications
- ETIM 6.0
- EC002654
- ETIM 7.0
- EC002654
- EClass 9.0
- 27-21-01-22
- EClass 9.1
- 27-21-01-22
- EClass 10.0
- 27-21-01-22
- UNSPSC
- 30-21-19-17
Insulation Coordination
- Clearance & creepage distances
- ≥ 5 mm (grout encapsulated)
- EMC standards
- EN 55011, EN 61000-6-1, 2, 3, 4
- Galvanic isolation
- Without isolation
- Impulse withstand voltage
- 6 kV
- Insulation voltage
- 4 kVeff / 1 min.
- Pollution severity
- 2
- Rated voltage
- 300 V
- Surge voltage category
- III
Temperatures
- Humidity
- 5-95% relative humidity, Tu = 40°C, without condensation
- Operating temperature, max.
- 55 °C
- Operating temperature, min.
- 0 °C
- Storage temperature, max.
- 85 °C
- Storage temperature, min.
- -40 °C
- Operating temperature
- 0 °C...55 °C
- Storage temperature
- -40 °C...85 °C
Ratings Iecex/Atex/Cul
- Certificate no. (cULus)
- E141197
Other Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther