Weidmuller

8951780000

VSPC BASE 2SL FG R
8951780000
8951780000
8951780000
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.
Offer with manufacturer lead time
Ships in:On Request
Best price:
€19.05

Additional Information

Part Number
8951780000

Further Details Of Approvals

GOST certificate
GOST-Zertifikat

General Data

Colour
black
Design
Terminal, miscellaneous
Optical function display
No
Protection degree
IP20
Rail
TS 35, TS 35 x 7.5
Segment
Measurement - Monitoring - Setting
UL 94 flammability rating
V-0
Version
Flange-mounted housing

Approvals

Approvals
CE, CSAEX, EAC, UL
ROHS
Conform
UL File Number Search
E311081

Insulation Coordination Acc. To En 50178

Pollution severity
2
Surge voltage category
III

Rated Data Iec / En

Dielectric strength at FG against PE
≥ 500 V
Leakage current at U
0 µA
Rated current I
300 mA
Signalling contact
UN 250 V AC 0.1 A 1CO at VSPC R with VSPC control unit
Standards
IEC 61643-21, IEC 62305, DIN EN 60079-0.2009, DIN EN 60079-11:2007, DIN EN 60079-26:2007, DIN EN 61241-11:2006
Voltage type
AC/DC

Dimensions And Weights

Width
17.8 mm
Width (inches)
0.701 inch
Height
98 mm
Height (inches)
3.858 inch
Depth
69 mm
Depth (inches)
2.717 inch
Net weight
72 g

Csa Protection Data

Gas group C
IIB
Gas group D
IIA
Gas groups A, B
IIC
Input current, max. I
300 mA
Internal inductance, max. L
0 µH

Connection Data

Type of connection
Screw connection
Stripping length, rated connection
7 mm
Tightening torque, min.
0.5 Nm
Tightening torque, max.
0.8 Nm
Clamping range, min.
0.5 mm²
Clamping range, max.
4 mm²
Wire cross-section, solid, min.
0.5 mm²
Wire cross-section, solid, max.
4 mm²
Wire connection cross section, finely stranded, max.
2.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.
0.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.
2.5 mm²
Connection cross-section, stranded, min.
0.5 mm²
Connection cross-section, stranded, max.
2.5 mm²
Blade size
0.6 x 3.5 mm

Rated Data Ul

Certificate No. (UL)
E311081
UL certificate
UL 497b Certificate

Tender Specification Sheets

Long specification
Base element can take a protected plug for up to two floating-ground powered paired cables. When the base unit is fitted, a simultaneous sparkover gap to high impedance earth is made between the mounting rail (earth) and the reference potential (ground) of the protective switch in the plug. With remote monitoring function. Mechanical coding of the base element to the protected plug according to switching type and rated voltage. The base unit is coded itself by the first insertion of a protected plug. Possible to mark all terminals
Short specification
Base element receives a protected plug for two floating-ground powered paired cables with indirect earthing. With optional remote monitoring.

Classifications

ETIM 6.0
EC000472
ETIM 7.0
EC000472
EClass 9.0
27-13-08-03
EClass 9.1
27-13-08-07
EClass 10.0
27-13-08-03
UNSPSC
30-21-19-21

Environmental Product Compliance

REACH SVHC
Lead 7439-92-1

Connection Data, Remote Alert

Connection type
Screw connection
Max. torque
0.2 Nm
Stripping length
6 mm
Cross-section for connected wire, solid core, min.
0.5 mm²
Cross-section for connected wire, solid core, max.
1.5 mm²

Temperatures

Humidity
5...96 %
Operating temperature, max.
70 °C
Operating temperature, min.
-40 °C
Storage temperature, max.
80 °C
Storage temperature, min.
-40 °C
Operating temperature
-40 °C...70 °C
Storage temperature
-40 °C...80 °C

Ratings Iecex/Atex/Cul

CUL certificate
cUL Certificate