B-Line

277135

Eaton Moeller® series DILM Contactor, 3 pole, 380 V 400 V 11 kW, 1 N/O, 415 V 50 Hz, 480 V 60 Hz, AC operation, Screw terminals
277135
277135
277135
277135
277135
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Additional Information

Part Number
277135

Specifications

Contact configuration
1 NO
Terminal capacity (flexible with ferrule)
2 x (0.75 - 10) mm², Main cables
Rated operational current for specified heat dissipation (In)
25 A
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
Rated operational power at AC-3, 380/400 V, 50 Hz
11 kW
Conventional thermal current ith (3-pole, enclosed)
36 A
Rated operational power at AC-4, 380/400 V, 50 Hz
6 kW
Rated operational current (Ie) at AC-4, 440 V
13 A
Rated control supply voltage (Us) at AC, 50 Hz - min
415 V
10.4 Clearances and creepage distances
Meets the product standard's requirements.
Number of contacts (normally closed) as main contact
0
Conventional thermal current ith at 55°C (3-pole, open)
42 A
Rated operational power (NEMA)
11 kW
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
Ambient storage temperature - min
40 °C
Rated breaking capacity at 380/400 V
250 A
Rated control supply voltage (Us) at AC, 50 Hz - max
415 V
Rated breaking capacity at 660/690 V
150 A
Rated operational current (Ie) at DC-1, 220 V
40 A
Ambient operating temperature - max
60 °C
Rated operational power at AC-4, 440 V, 50 Hz
7 kW
Electrical connection type of main circuit
Screw connection
Number Of Poles
Three-pole
Ambient operating temperature - min
-25 °C
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
Application
Contactors for Motors
Operating frequency
5000 mechanical Operations/h (AC operated)
Voltage type
AC
Short-circuit protection rating (type 1 coordination) at 400 V
100 A gG/gL
Product category
Contactors
Rated operational current (Ie) at AC-4, 220 V, 230 V, 240 V
13 A
Power consumption, pick-up, 50 Hz
52 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz
Heat dissipation capacity Pdiss
0 W
Switching time (AC operated, make contacts, opening delay) - min
8 ms
Continuous ampere rating
170 A
Rated operational current (Ie) at AC-4, 500 V
13 A
Rated operational power at AC-3, 240 V, 50 Hz
8.5 kW
Terminal capacity (solid/stranded AWG)
Single 18 - 6, double 18 - 8, Main cables
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
Degree of protection
IP00
Overvoltage category
III
Switching time (AC operated, make contacts, opening delay) - max
14 ms
Ambient storage temperature - max
80 °C
Pollution degree
3
Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V
45 A
Power consumption, pick-up, 60 Hz
67 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz
Switching time (AC operated, make contacts, closing delay) - max
22 ms
Rated impulse withstand voltage (Uimp)
8000 V AC
Connection
Screw connection
Tightening torque
1.2 Nm, Screw terminals, Control circuit cables
Rated operational power at AC-4, 660/690 V, 50 Hz
8.5 kW
Conventional thermal current ith (1-pole, enclosed)
90 A
Rated operational current (Ie) at AC-3, 660 V, 690 V
15 A
Type
Full voltage non-reversing small contactor
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.7 Inscriptions
Meets the product standard's requirements.
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V
25 A
Number of contacts (normally open contacts)
1
Switching time (AC operated, make contacts, closing delay) - min
16 ms
Short-circuit protection rating (type 2 coordination) at 400 V
35 A gG/gL
Number of auxiliary contacts (normally open contacts)
1
Shock resistance
10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
Rated operational current (Ie) at DC-1, 110 V
40 A
Drop-out voltage
AC operated: 0.6 - 0.3 x UC, AC operated
Power consumption, sealing, 60 Hz
2.1 W, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz
Resistance per pole
2.7 mΩ
Ambient operating temperature (enclosed) - min
25 °C
Stripping length (control circuit cable)
10 mm
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
Amperage Rating
170A
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
Stripping length (main cable)
10 mm
Ambient operating temperature (enclosed) - max
40 °C
Rated control supply voltage (Us) at DC - min
0 V
Frequency rating
50-60 Hz
10.8 Connections for external conductors
Is the panel builder's responsibility.
Number of main contacts (normally open contact)
3
Rated breaking capacity at 220/230 V
250 A
Screw size
M5, Terminal screw, Main cables
Rated operational current (Ie) at AC-4, 400 V
13 A
Terminals
Screw terminals
Short-circuit protection rating (type 2 coordination) at 690 V
35 A gG/gL
Protection
Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
Power consumption, sealing, 50 Hz
7.1 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz
Terminal capacity (stranded)
1 x 16 mm², Main cables
Rated breaking capacity at 500 V
250 A
Rated operational power at AC-3, 415 V, 50 Hz
14.5 kW
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Emitted interference
According to EN 60947-1
Connection to SmartWire-DT
No
Static heat dissipation, non-current-dependent Pvs
2.1 W
Rated control supply voltage (Us) at DC - max
0 V
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
Utilization category
AC-4: Normal AC induction motors: starting, plugging, reversing, inching
Coil voltage
415-480 Vac, 50/60 Hz
Rated operational current (Ie) at AC-3, 440 V
25 A
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
Safe isolation
440 V AC, Between coil and contactss, According to EN 61140
Used with
Can be combined with auxiliary contacts: DILM32-XHI, DILA-XHI(V)
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
Heat dissipation per pole, current-dependent Pvid
1.4 W
Operating temperature - min
-40 °C
Rated operational current (Ie) at AC-4, 660 V, 690 V
10 A
Equipment heat dissipation, current-dependent Pvid
4.2 W
Pick-up voltage
0.8 - 1.1 V AC x Uc
Suitable for
Also motors with efficiency class IE3
Operation
Reversing
Terminal capacity (solid)
2 x (0.75 - 10) mm², Main cables
Number of auxiliary contacts (normally closed contacts)
0
Interference immunity
According to EN 60947-1
Power consumption
11 kW
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
Operating temperature - max
60 °C
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
Lifespan, mechanical
10,000,000 Operations (AC operated)
Short-circuit protection rating (type 1 coordination) at 690 V
50 A gG/gL
Rated making capacity up to 690 V (cos phi to IEC/EN 60947)
350 A
Rated operational power at AC-4, 240 V, 50 Hz
4 kW
Rated operational power at AC-4, 500 V, 50 Hz
8 kW
Voltage rating
400 V
Number of contacts
1 NO
Rated operational current (Ie) at DC-1, 60 V
40 A
Rated operational power at AC-4, 220/230 V, 50 Hz
3.5 kW
Rated operational voltage (Ue) at AC - max
690 V
Rated control supply voltage (Us) at AC, 60 Hz - min
480 V
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Rated operational current (Ie) at AC-3, 500 V
25 A
Screwdriver size
2, Terminal screw, Pozidriv screwdriver
Duty factor
100 %
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V
25 A
Conventional thermal current ith of main contacts (1-pole, open)
100 A
Rated control supply voltage (Us) at AC, 60 Hz - max
480 V
Arcing time
10 ms
Rated operational power at AC-4, 415 V, 50 Hz
6.5 kW
Rated insulation voltage (Ui)
690 V

General

Model Code
DILM25-10(415V50HZ,480V60HZ)
EAN
4015082771355
Product Length/Depth
97 mm
Product Height
85 mm
Product Width
45 mm
Product Weight
.428 kg
Certifications
UL
Catalog Notes
Contacts according to EN 50012|IE3-ready devices are identified by the logo on their packaging.

Related products