Benötigen Sie weitere Informationen?

Rufen Sie uns an unter:+48 17 778 34 19

Honeywell HVFDSB3A0015G220/U

VFD with Bypass and Disconnect, SmartVFD BYPASS, 208Vac, 1.5 HP, Graphical, NEMA 12 Enclosure, Two Contactor Bypass

1 / 3
Honeywell HVFDSB3A0015G220/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 208Vac, 1.5 HP, Graphical, NEMA 12 Enclosure, Two Contactor Bypass — Frequenzumrichter
Katalogbild des Herstellers
Honeywell HVFDSB3A0015G220/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 208Vac, 1.5 HP, Graphical, NEMA 12 Enclosure, Two Contactor Bypass — Frequenzumrichter
Katalogbild des Herstellers
Honeywell HVFDSB3A0015G220/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 208Vac, 1.5 HP, Graphical, NEMA 12 Enclosure, Two Contactor Bypass — Frequenzumrichter
Katalogbild des Herstellers
Honeywell HVFDSB3A0015G220/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 208Vac, 1.5 HP, Graphical, NEMA 12 Enclosure, Two Contactor Bypass — Frequenzumrichter
Honeywell HVFDSB3A0015G220/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 208Vac, 1.5 HP, Graphical, NEMA 12 Enclosure, Two Contactor Bypass — Frequenzumrichter
Honeywell HVFDSB3A0015G220/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 208Vac, 1.5 HP, Graphical, NEMA 12 Enclosure, Two Contactor Bypass — Frequenzumrichter

Produktbeschreibung

The VFD with Bypass and Disconnect, identified as SmartVFD BYPASS, operates at an input voltage of 208V AC and is equipped with a 1.5 HP motor rating. This device effectively modulates the speed of fans and pumps within HVAC systems, contributing to substantial energy conservation.

Integration with building automation systems (BAS) or use of its internal PID control capabilities allows for optimized performance. The device includes an intuitive graphical interface, facilitating straightforward commissioning alongside startup wizards and PC programming features.

With an overall width of 12 inches (305 mm), height of 37.5 inches (953 mm), and depth of 11 inches (279 mm), the VFD is housed in a NEMA 12 enclosure. The unit weighs 18.2 pounds (40 kg) and is capable of operating efficiently across a range of environmental conditions, with a maximum operating temperature of 104 °F (40 °C) and minimum operating temperature of 14 °F (-10 °C).

Notable specifications include a continuous output current rating of 6.6 A and a control transformer. The device supports various analog inputs and outputs, including options for 0-10Vdc and 0(4)-20mA signals. The VFD also features a maximum acceleration and deceleration time of 3000 seconds, accommodating a variety of application needs.

Regulatory approvals include CE and cUL, ensuring compliance with established standards. This model is specifically designed for variable torque applications, making it suitable for a range of HVAC operations.

Benötigen Sie weitere Informationen?

Rufen Sie uns an unter:+48 17 778 34 19
  • Erhalten Sie bis zu 90 Tage Zahlungsziele von 500+ Lieferanten
  • Wiederverkaufsrabatte bis zu 40%!
Preisanfrage senden
Zahlungsmöglichkeiten:
Fordern Sie ein Angebot an und wir senden Ihnen Informationen zu Verfügbarkeit und Preis.

Spezifikationen

Type of RFI Filter
EMC Filter
Relay Rated Load
Max load: 250Vac/2A- 250Vdc/0.4A
Regulatory Approvals
CE ; EN 61800-5-1 ; cUL
Reference Output Voltage
10 Vdc- max load 10 mA
Pilot Lights
No
Peak Current
IS- 2s/20s

Dokumente

Datenblatt

Datenblatt für Honeywell HVFDSB3A0015G220/U, einschließlich Spezifikationen und Funktionen.

Datenblatt herunterladen
TraceParts

CAD-Modelle

3D-CAD-Modell und technische Zeichnungen, bereit für Ihre Konstruktionssoftware.

CAD-Modell herunterladen
AutomaINSIGHTS-Analyse-Dashboard für HVFDSB3A0015G220/U

Markteinblicke für HVFDSB3A0015G220/U

Erhalten Sie Echtzeit-Analysen und Marktdaten zu HVFDSB3A0015G220/U und weiteren Produkten aus der Kategorie Frequenzumrichter, um Ihre Kaufentscheidungen zu optimieren.

  • Echtzeit-Verfügbarkeitsdaten von über 700 MRO-Händlern in Europa und den USA
  • Preisanalyse nach Zustand (neu, gebraucht, überholt) mit Marktmedianpreisen
  • Überwachung der Verfügbarkeit kritischer Komponenten zur Vermeidung von Produktionsausfällen

Verwandte Kategorien