Benötigen Sie weitere Informationen?

Rufen Sie uns an unter:+48 17 778 34 19

Honeywell HVFDSB3A0250G231/U

VFD with Bypass and Disconnect, SmartVFD BYPASS, 208Vac, 25 HP, Graphical, NEMA 12 Enclosure

1 / 3
Honeywell HVFDSB3A0250G231/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 208Vac, 25 HP, Graphical, NEMA 12 Enclosure — Frequenzumrichter
Katalogbild des Herstellers
Honeywell HVFDSB3A0250G231/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 208Vac, 25 HP, Graphical, NEMA 12 Enclosure — Frequenzumrichter
Katalogbild des Herstellers
Honeywell HVFDSB3A0250G231/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 208Vac, 25 HP, Graphical, NEMA 12 Enclosure — Frequenzumrichter
Katalogbild des Herstellers
Honeywell HVFDSB3A0250G231/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 208Vac, 25 HP, Graphical, NEMA 12 Enclosure — Frequenzumrichter
Honeywell HVFDSB3A0250G231/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 208Vac, 25 HP, Graphical, NEMA 12 Enclosure — Frequenzumrichter
Honeywell HVFDSB3A0250G231/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 208Vac, 25 HP, Graphical, NEMA 12 Enclosure — Frequenzumrichter

Produktbeschreibung

The variable frequency drive (VFD) with model designation SmartVFD BYPASS is designed to optimize energy efficiency by modulating the operation of HVAC system components such as fans and pumps. With an input voltage of 208 V AC and a power rating of 25 HP, this drive integrates seamlessly with building automation systems (BAS) or can function independently using its internal PID capabilities.

This VFD features a three-contactor bypass with auto bypass functionality, ensuring reliable operation while minimizing downtime. The NEMA 12 enclosure provides suitable protection for various environments, while the graphical interface facilitates quick commissioning through intuitive controls. Key specifications include continuous output current rated at 75 A, and it supports both variable torque applications.

Additionally, the device is equipped with an EMC filter to enhance performance and compatibility, and it meets several regulatory standards, including CE and EN 61800-5-1. The operational temperature ranges from 14 °F to 104 °F, with a maximum relative humidity of 95%. The VFD is also designed for easy installation with features such as input disconnect and drive input fuses.

Benötigen Sie weitere Informationen?

Rufen Sie uns an unter:+48 17 778 34 19
  • Erhalten Sie bis zu 90 Tage Zahlungsziele von 500+ Lieferanten
  • Wiederverkaufsrabatte bis zu 40%!
Preisanfrage senden
Zahlungsmöglichkeiten:
Fordern Sie ein Angebot an und wir senden Ihnen Informationen zu Verfügbarkeit und Preis.

Spezifikationen

Type of RFI Filter
EMC Filter
Relay Rated Load
Max load: 250Vac/2A- 250Vdc/0.4A
Regulatory Approvals
CE ; EN 61800-5-1 ; cUL
Reference Output Voltage
10 Vdc- max load 10 mA
Pilot Lights
Yes
Peak Current
IS- 2s/20s

Dokumente

Datenblatt

Datenblatt für Honeywell HVFDSB3A0250G231/U, einschließlich Spezifikationen und Funktionen.

Datenblatt herunterladen
TraceParts

CAD-Modelle

3D-CAD-Modell und technische Zeichnungen, bereit für Ihre Konstruktionssoftware.

CAD-Modell herunterladen
AutomaINSIGHTS-Analyse-Dashboard für HVFDSB3A0250G231/U

Markteinblicke für HVFDSB3A0250G231/U

Erhalten Sie Echtzeit-Analysen und Marktdaten zu HVFDSB3A0250G231/U und weiteren Produkten aus der Kategorie Frequenzumrichter, um Ihre Kaufentscheidungen zu optimieren.

  • Echtzeit-Verfügbarkeitsdaten von über 700 MRO-Händlern in Europa und den USA
  • Preisanalyse nach Zustand (neu, gebraucht, überholt) mit Marktmedianpreisen
  • Überwachung der Verfügbarkeit kritischer Komponenten zur Vermeidung von Produktionsausfällen

Verwandte Kategorien