Honeywell HVFDSB3A0500G130/U

VFD with Bypass and Disconnect, SmartVFD BYPASS, 208VAC, 50 HP, NEMA 1 Enclosure, Three Contactor Bypass

1 / 3
Honeywell HVFDSB3A0500G130/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 208VAC, 50 HP, NEMA 1 Enclosure, Three Contactor Bypass — Frequenzumrichter
Katalogbild des Herstellers
Honeywell HVFDSB3A0500G130/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 208VAC, 50 HP, NEMA 1 Enclosure, Three Contactor Bypass — Frequenzumrichter
Katalogbild des Herstellers
Honeywell HVFDSB3A0500G130/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 208VAC, 50 HP, NEMA 1 Enclosure, Three Contactor Bypass — Frequenzumrichter
Katalogbild des Herstellers
Honeywell HVFDSB3A0500G130/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 208VAC, 50 HP, NEMA 1 Enclosure, Three Contactor Bypass — Frequenzumrichter
Honeywell HVFDSB3A0500G130/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 208VAC, 50 HP, NEMA 1 Enclosure, Three Contactor Bypass — Frequenzumrichter
Honeywell HVFDSB3A0500G130/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 208VAC, 50 HP, NEMA 1 Enclosure, Three Contactor Bypass — Frequenzumrichter

Produktbeschreibung

The VFD with Bypass and Disconnect, SmartVFD BYPASS, operates at 208VAC and is designed for a 50 HP capacity. This device is particularly suitable for variable torque applications, effectively managing the speed of fans and pumps in HVAC systems to achieve energy efficiency.

This unit includes a three contactor bypass system, enhancing operational flexibility. It supports a continuous output current of up to 140 A and features an input disconnect for safety during maintenance. The enclosure is rated NEMA 1, suitable for indoor applications.

The drive is equipped with EMC filtering and complies with various regulatory standards including CE, EN 61800-5-1, and cUL. It operates reliably within a temperature range from -40 °F to 158 °F and can handle humidity levels up to 95%. The SmartVFD also features built-in PID control capabilities, allowing for integration with building automation systems or standalone operation.

Notable specifications include a maximum deceleration and acceleration time of up to 3000 seconds, ensuring smooth control over varying operational demands. The device also includes analog input and output options for enhanced control and monitoring, making it a versatile choice for HVAC applications.

Benötigen Sie weitere Informationen?

Rufen Sie uns an unter:+48 17 778 34 19
  • Erhalten Sie bis zu 90 Tage Zahlungsziele von 500+ Lieferanten
  • Wiederverkaufsrabatte bis zu 40%!
Preisanfrage senden
Zahlungsmöglichkeiten:
Fordern Sie ein Angebot an und wir senden Ihnen Informationen zu Verfügbarkeit und Preis.

Spezifikationen

Type of RFI Filter
EMC Filter
Relay Rated Load
Max load: 250Vac/2A- 250Vdc/0.4A
Regulatory Approvals
CE ; EN 61800-5-1 ; cUL
Reference Output Voltage
10 Vdc- max load 10 mA
Pilot Lights
Yes
Peak Current
IS- 2s/20s

Dokumente

Datenblatt

Datenblatt für Honeywell HVFDSB3A0500G130/U, einschließlich Spezifikationen und Funktionen.

Datenblatt herunterladen
TraceParts

CAD-Modelle

3D-CAD-Modell und technische Zeichnungen, bereit für Ihre Konstruktionssoftware.

CAD-Modell herunterladen
AutomaINSIGHTS-Analyse-Dashboard für HVFDSB3A0500G130/U

Markteinblicke für HVFDSB3A0500G130/U

Erhalten Sie Echtzeit-Analysen und Marktdaten zu HVFDSB3A0500G130/U und weiteren Produkten aus der Kategorie Frequenzumrichter, um Ihre Kaufentscheidungen zu optimieren.

  • Echtzeit-Verfügbarkeitsdaten von über 700 MRO-Händlern in Europa und den USA
  • Preisanalyse nach Zustand (neu, gebraucht, überholt) mit Marktmedianpreisen
  • Überwachung der Verfügbarkeit kritischer Komponenten zur Vermeidung von Produktionsausfällen

Verwandte Kategorien