Honeywell HVFDSB3B0030G220/U

VFD with Bypass and Disconnect, SmartVFD BYPASS, 230 Vac, 3 HP, Graphical, NEMA 12 Enclosure, Two Contactor Bypass

1 / 3
Honeywell HVFDSB3B0030G220/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 230 Vac, 3 HP, Graphical, NEMA 12 Enclosure, Two Contactor Bypass — Frequenzumrichter
Katalogbild des Herstellers
Honeywell HVFDSB3B0030G220/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 230 Vac, 3 HP, Graphical, NEMA 12 Enclosure, Two Contactor Bypass — Frequenzumrichter
Katalogbild des Herstellers
Honeywell HVFDSB3B0030G220/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 230 Vac, 3 HP, Graphical, NEMA 12 Enclosure, Two Contactor Bypass — Frequenzumrichter
Katalogbild des Herstellers
Honeywell HVFDSB3B0030G220/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 230 Vac, 3 HP, Graphical, NEMA 12 Enclosure, Two Contactor Bypass — Frequenzumrichter
Honeywell HVFDSB3B0030G220/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 230 Vac, 3 HP, Graphical, NEMA 12 Enclosure, Two Contactor Bypass — Frequenzumrichter
Honeywell HVFDSB3B0030G220/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 230 Vac, 3 HP, Graphical, NEMA 12 Enclosure, Two Contactor Bypass — Frequenzumrichter

Produktbeschreibung

The variable frequency drive (VFD) with a bypass option is designed to optimize energy usage by controlling the speed of fans and pumps within HVAC systems. This unit operates effectively either as part of a building automation system (BAS) or independently utilizing its internal PID control capabilities. Key features include a user-friendly graphical interface that enhances the commissioning process.

The drive is equipped with two contactor bypass functionality, rated for 3 HP at an input voltage of 230 Vac. The Designation Code provides insight into its capabilities, which include an overall width of 12 inches and a height of 37.5 inches, with a depth of 11 inches. The unit weighs 18.2 pounds.

It incorporates an EMC filter to minimize electromagnetic interference and supports a continuous output current with overload capabilities. With a maximum ambient temperature of 104 °F and a minimum operating temperature of 14 °F, this drive is suitable for a range of environmental conditions. Furthermore, it features a NEMA 12 enclosure, ensuring protection against dust and indirect water, making it ideal for various indoor applications.

Benötigen Sie weitere Informationen?

Rufen Sie uns an unter:+48 17 778 34 19
  • Erhalten Sie bis zu 90 Tage Zahlungsziele von 500+ Lieferanten
  • Wiederverkaufsrabatte bis zu 40%!
Preisanfrage senden
Zahlungsmöglichkeiten:
Fordern Sie ein Angebot an und wir senden Ihnen Informationen zu Verfügbarkeit und Preis.

Spezifikationen

Type of RFI Filter
EMC Filter
Relay Rated Load
Max load: 250Vac/2A- 250Vdc/0.4A
Regulatory Approvals
CE ; EN 61800-5-1 ; cUL
Reference Output Voltage
10 Vdc- max load 10 mA
Pilot Lights
No
Peak Current
IS- 2s/20s

Dokumente

Datenblatt

Datenblatt für Honeywell HVFDSB3B0030G220/U, einschließlich Spezifikationen und Funktionen.

Datenblatt herunterladen
TraceParts

CAD-Modelle

3D-CAD-Modell und technische Zeichnungen, bereit für Ihre Konstruktionssoftware.

CAD-Modell herunterladen
AutomaINSIGHTS-Analyse-Dashboard für HVFDSB3B0030G220/U

Markteinblicke für HVFDSB3B0030G220/U

Erhalten Sie Echtzeit-Analysen und Marktdaten zu HVFDSB3B0030G220/U und weiteren Produkten aus der Kategorie Frequenzumrichter, um Ihre Kaufentscheidungen zu optimieren.

  • Echtzeit-Verfügbarkeitsdaten von über 700 MRO-Händlern in Europa und den USA
  • Preisanalyse nach Zustand (neu, gebraucht, überholt) mit Marktmedianpreisen
  • Überwachung der Verfügbarkeit kritischer Komponenten zur Vermeidung von Produktionsausfällen

Verwandte Kategorien