Honeywell HVFDSB3B0300G320/U

VFD with Bypass and Disconnect, SmartVFD BYPASS, 230 Vac, 30 HP, Graphical, NEMA 3R Enclosure, Two Contactor Bypass

1 / 3
Honeywell HVFDSB3B0300G320/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 230 Vac, 30 HP, Graphical, NEMA 3R Enclosure, Two Contactor Bypass — Stromversorgung
Katalogbild des Herstellers
Honeywell HVFDSB3B0300G320/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 230 Vac, 30 HP, Graphical, NEMA 3R Enclosure, Two Contactor Bypass — Stromversorgung
Katalogbild des Herstellers
Honeywell HVFDSB3B0300G320/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 230 Vac, 30 HP, Graphical, NEMA 3R Enclosure, Two Contactor Bypass — Stromversorgung
Katalogbild des Herstellers
Honeywell HVFDSB3B0300G320/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 230 Vac, 30 HP, Graphical, NEMA 3R Enclosure, Two Contactor Bypass — Stromversorgung
Honeywell HVFDSB3B0300G320/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 230 Vac, 30 HP, Graphical, NEMA 3R Enclosure, Two Contactor Bypass — Stromversorgung
Honeywell HVFDSB3B0300G320/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 230 Vac, 30 HP, Graphical, NEMA 3R Enclosure, Two Contactor Bypass — Stromversorgung

Produktbeschreibung

The variable frequency drive (VFD) facilitates energy efficiency by adjusting the speed of HVAC system fans and pumps. This model, equipped with a two contactor bypass, is designed to operate at 230 Vac and deliver up to 30 HP. The intuitive graphical interface enhances commissioning speed and accuracy, while its compliance with standards such as CE and EN 61800-5-1 ensures regulatory adherence.

Incorporating features like an EMC filter and a control transformer, the system supports variable torque applications. Its operational versatility is emphasized by a current rating of 88 A and a minimum acceleration and deceleration time of just 0.1 seconds. The device operates efficiently within a temperature range of -10 °C to 40 °C and humidity levels up to 95%, making it suitable for a variety of environments.

Designed for integration with building automation systems (BAS) or standalone use via internal PID controls, this VFD allows for significant energy savings. Its physical dimensions include a width of 28.5 in (724 mm), a height of 48 in (1219 mm), and a depth of 12.5 in (318 mm), with a total weight of 185 lbs (84.1 kg). This model is categorized under the SmartVFD HVAC family, reflecting its specialized application in heating, ventilation, and air conditioning.

  • Erhalten Sie bis zu 90 Tage Zahlungsziele von 500+ Lieferanten
  • Wiederverkaufsrabatte bis zu 40%!
Sign Up
Preisanfrage senden
Anfrage senden
Zahlungsmöglichkeiten:
Fordern Sie ein Angebot an und wir senden Ihnen Informationen zu Verfügbarkeit und Preis.

Spezifikationen

Type of RFI Filter
EMC Filter
Relay Rated Load
Max load: 250Vac/2A- 250Vdc/0.4A
Regulatory Approvals
CE ; EN 61800-5-1 ; cUL
Reference Output Voltage
10 Vdc- max load 10 mA
Pilot Lights
No
Peak Current
IS- 2s/20s

Auf unserer Plattform finden Sie weitere Angebote

Registrieren Sie sich jetzt, um 36 Mio. Angebote von verifizierten Anbietern weltweit zu entdecken.

  • Angebote weltweit vergleichen
  • Direkter Lieferantenkontakt
  • RFQs, Angebote und Aufträge
  • BOM-Suche
Sign UpKostenlose 14-tägige Testversion verfügbar

Dokumente

Datenblatt

Datenblatt für Honeywell HVFDSB3B0300G320/U, einschließlich Spezifikationen und Funktionen.

Datenblatt herunterladen
TracePartsTraceParts

CAD Models

3D-CAD-Modell und technische Zeichnungen, bereit für Ihre Konstruktionssoftware.

CAD-Modell herunterladen

Einblicke in den Markt

AutomaINSIGHTS Analyse-Dashboard

Erhalten Sie Echtzeit-Analysen und Marktdaten, um Ihre Kaufentscheidungen für diese Komponente und ähnliche Produkte zu optimieren.

  • Echtzeit-Verfügbarkeitsdaten von über 700 MRO-Händlern in Europa und den USA
  • Preisanalyse nach Zustand (neu, gebraucht, überholt) mit Marktmedianpreisen
  • Überwachung der Verfügbarkeit kritischer Komponenten zur Vermeidung von Produktionsausfällen
  • Erkenntnisse zur Bestandsoptimierung auf der Grundlage von Marktangebotstrends
Starten