Benötigen Sie weitere Informationen?

Rufen Sie uns an unter:+48 17 778 34 19

Honeywell HVFDSB3B0500G131/U

VFD with Bypass and Disconnect, SmartVFD BYPASS, 230VAC, 50 HP, NEMA 1 Enclosure, Three Contactor Bypass with Auto Bypass

1 / 3
Honeywell HVFDSB3B0500G131/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 230VAC, 50 HP, NEMA 1 Enclosure, Three Contactor Bypass with Auto Bypass — Netzgeräte & Leistungsregler
Katalogbild des Herstellers
Honeywell HVFDSB3B0500G131/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 230VAC, 50 HP, NEMA 1 Enclosure, Three Contactor Bypass with Auto Bypass — Netzgeräte & Leistungsregler
Katalogbild des Herstellers
Honeywell HVFDSB3B0500G131/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 230VAC, 50 HP, NEMA 1 Enclosure, Three Contactor Bypass with Auto Bypass — Netzgeräte & Leistungsregler
Katalogbild des Herstellers
Honeywell HVFDSB3B0500G131/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 230VAC, 50 HP, NEMA 1 Enclosure, Three Contactor Bypass with Auto Bypass — Netzgeräte & Leistungsregler
Honeywell HVFDSB3B0500G131/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 230VAC, 50 HP, NEMA 1 Enclosure, Three Contactor Bypass with Auto Bypass — Netzgeräte & Leistungsregler
Honeywell HVFDSB3B0500G131/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 230VAC, 50 HP, NEMA 1 Enclosure, Three Contactor Bypass with Auto Bypass — Netzgeräte & Leistungsregler

Produktbeschreibung

The variable frequency drive (VFD) with Bypass and Disconnect capabilities operates at 230VAC and is rated for 50 HP. With a NEMA 1 enclosure, this drive incorporates a three contactor bypass system that includes an auto bypass feature for enhanced operational efficiency.

This VFD is designed to optimize energy consumption by modulating the operation of fans and pumps specifically in HVAC applications. It can function seamlessly with a building automation system (BAS) or operate independently utilizing its internal PID control features.

Key specifications include an output voltage of 230 (3PH) V AC and a continuous output current overload rating of 1.1 x IL for 1 minute or 10 minutes. The device also features an EMC filter for RFI suppression and is equipped with drive input fuses and a drive input disconnect for safety compliance. The overall dimensions are 25 inches in width, 70 inches in height, and 16.2 inches in depth, with a total weight of 130.5 lbs.

Operating conditions are suitable for ambient temperatures ranging from 14 °F (-10 °C) to a maximum of 104 °F (40 °C) and a humidity range of 0% to 95%. The drive supports both analog inputs and outputs for versatile integration into existing systems.

  • Erhalten Sie bis zu 90 Tage Zahlungsziele von 500+ Lieferanten
  • Wiederverkaufsrabatte bis zu 40%!
Sign Up
Preisanfrage senden
Anfrage senden
Zahlungsmöglichkeiten:
Fordern Sie ein Angebot an und wir senden Ihnen Informationen zu Verfügbarkeit und Preis.

Spezifikationen

Type of RFI Filter
EMC Filter
Relay Rated Load
Max load: 250Vac/2A- 250Vdc/0.4A
Regulatory Approvals
CE ; EN 61800-5-1 ; cUL
Reference Output Voltage
10 Vdc- max load 10 mA
Pilot Lights
Yes
Peak Current
IS- 2s/20s

Auf unserer Plattform finden Sie weitere Angebote

Registrieren Sie sich jetzt, um 36 Mio. Angebote von verifizierten Anbietern weltweit zu entdecken.

  • Angebote weltweit vergleichen
  • Direkter Lieferantenkontakt
  • RFQs, Angebote und Aufträge
  • BOM-Suche
Sign UpKostenlose 14-tägige Testversion verfügbar

Dokumente

Datenblatt

Datenblatt für Honeywell HVFDSB3B0500G131/U, einschließlich Spezifikationen und Funktionen.

Datenblatt herunterladen
TracePartsTraceParts

CAD Models

3D-CAD-Modell und technische Zeichnungen, bereit für Ihre Konstruktionssoftware.

CAD-Modell herunterladen

Einblicke in den Markt

AutomaINSIGHTS Analyse-Dashboard

Erhalten Sie Echtzeit-Analysen und Marktdaten, um Ihre Kaufentscheidungen für diese Komponente und ähnliche Produkte zu optimieren.

  • Echtzeit-Verfügbarkeitsdaten von über 700 MRO-Händlern in Europa und den USA
  • Preisanalyse nach Zustand (neu, gebraucht, überholt) mit Marktmedianpreisen
  • Überwachung der Verfügbarkeit kritischer Komponenten zur Vermeidung von Produktionsausfällen
  • Erkenntnisse zur Bestandsoptimierung auf der Grundlage von Marktangebotstrends
Starten