Phoenix Contact
2811459
Signal conditioner - MACX MCR-UI-UI-UP - 2811459
- Erhalten Sie bis zu 90 Tage Zahlungsziele von 500+ Lieferanten
- Wiederverkaufsrabatte bis zu 40%!
Preisanfrage senden
1
Zahlungsmöglichkeiten:
Additional Information
- Part Number
- 2811459
- ETIM
- Group Code : EG000026
- Group Description : Sensors
- Class Description : Isolation amplifier
- Class Code : EC002653
- Version : 7
Input data
- Description of the input
- Measuring input
- Number of inputs
- 1
- Voltage input signal
- 0 mV - 50 mV
- Voltage input signal
- 0 mV - 60 mV
- Voltage input signal
- 0 mV - 75 mV
- Voltage input signal
- 0 mV - 100 mV
- Voltage input signal
- 0 mV - 120 mV
- Voltage input signal
- 0 mV - 150 mV
- Voltage input signal
- 0 mV - 200 mV
- Voltage input signal
- 0 mV - 300 mV
- Voltage input signal
- 0 mV - 500 mV
- Voltage input signal
- 0 V - 1 V
- Voltage input signal
- 0 V - 1.5 V
- Voltage input signal
- 0 V - 2 V
- Voltage input signal
- 0 V - 3 V
- Voltage input signal
- 0 V - 5 V
- Voltage input signal
- 0 V - 10 V (please indicate if different setting when ordering)
- Voltage input signal
- 0 V - 15 V
- Voltage input signal
- 0 V - 20 V
- Voltage input signal
- 0 V - 30 V
- Voltage input signal
- 0 V - 50 V
- Voltage input signal
- 0 V - 100 V
- Voltage input signal
- -50 mV - 50 mV
- Voltage input signal
- -60 mV - 60 mV
- Voltage input signal
- -75 mV - 75 mV
- Voltage input signal
- -100 mV - 100 mV
- Voltage input signal
- -120 mV - 120 mV
- Voltage input signal
- -150 mV - 150 mV
- Voltage input signal
- -200 mV - 200 mV
- Voltage input signal
- -300 mV - 300 mV
- Voltage input signal
- -500 mV - 500 mV
- Voltage input signal
- -1 V - 1 V
- Voltage input signal
- -1.5 V - 1.5 V
- Voltage input signal
- -2 V - 2 V
- Voltage input signal
- -3 V - 3 V
- Voltage input signal
- -5 V - 5 V
- Voltage input signal
- -10 V - 10 V
- Voltage input signal
- -15 V - 15 V
- Voltage input signal
- -20 V - 20 V
- Voltage input signal
- -30 V - 30 V
- Voltage input signal
- -50 V - 50 V
- Voltage input signal
- -100 V - 100 V
- Voltage input signal
- 1 V - 5 V
- Voltage input signal
- 2 V - 10 V
- Current input signal
- 0 mA - 1 mA (Configurable via DIP switches)
- Current input signal
- 0 mA - 1.5 mA
- Current input signal
- 0 mA - 2 mA
- Current input signal
- 0 mA - 3 mA
- Current input signal
- 0 mA - 5 mA
- Current input signal
- 0 mA - 10 mA
- Current input signal
- 0 mA - 15 mA
- Current input signal
- 0 mA - 20 mA
- Current input signal
- 0 mA - 30 mA
- Current input signal
- 0 mA - 50 mA
- Current input signal
- 0 mA - 100 mA
- Current input signal
- -1 mA - 1 mA
- Current input signal
- -1.5 mA - 1.5 mA
- Current input signal
- -2 mA - 2 mA
- Current input signal
- -3 mA - 3 mA
- Current input signal
- -5 mA - 5 mA
- Current input signal
- -10 mA - 10 mA
- Current input signal
- -15 mA - 15 mA
- Current input signal
- -20 mA - 20 mA
- Current input signal
- -30 mA - 30 mA
- Current input signal
- -50 mA - 50 mA
- Current input signal
- -100 mA - 100 mA
- Current input signal
- 1 mA - 5 mA
- Current input signal
- 2 mA - 10 mA
- Current input signal
- 4 mA - 20 mA
- Max. input voltage
- ± 100 V
- Max. input current
- ± 100 mA
- Input resistance of voltage input
- approx. 1 MΩ (±1 V DC - ±100 V DC)
- Input resistance current input
- approx. 10 Ω (± 10 mA DC - ± 100 mA DC)
Note
- Utilization restriction
- EMC: class A product, see manufacturer's declaration in the download area
Dimensions
- Width
- 12.5 mm
- Height
- 112.5 mm
- Depth
- 113.7 mm
Connection data
- Connection method
- Screw connection
- Connection technology
- COMBICON
- Stripping length
- 8 mm
- Screw thread
- M3
- Conductor cross section solid
- 0.2 mm² - 2.5 mm²
- Conductor cross section flexible
- 0.2 mm² - 2.5 mm²
- Conductor cross section AWG
- 24 - 14
Output data
- Output name
- Screw fastening
- Number of outputs
- 1
- Configurable/programmable
- Yes, can be switched
- Voltage output signal
- 0 V - 10 V (Configurable via DIP switches)
- Voltage output signal
- 0 V - 5 V
- Voltage output signal
- 2 V - 10 V
- Voltage output signal
- 1 V - 5 V
- Voltage output signal
- -10 V - 10 V
- Voltage output signal
- -5 V - 5 V
- Voltage output signal
- 0 V - 2.5 V
- Voltage output signal
- 0.5 V - 2.5 V
- Voltage output signal
- -2.5 V - 2.5 V
- Current output signal
- 0 mA - 5 mA
- Current output signal
- 0 mA - 10 mA
- Current output signal
- 0 mA - 20 mA (Configurable via DIP switches)
- Current output signal
- 1 mA - 5 mA
- Current output signal
- 2 mA - 10 mA
- Current output signal
- 4 mA - 20 mA
- Current output signal
- -5 mA - 5 mA
- Current output signal
- -10 mA - 10 mA
- Current output signal
- -20 mA - 20 mA
- Max. output voltage
- 15 V
- Max. output current
- 35 mA
- Load/output load voltage output
- ≥ 1 kΩ (10 V)
- Load/output load current output
- ≤ 600 Ω (20 mA; active)
- Load/output load current output
- passive: ≤ (UB-2 V) / Ioutmax
- Ripple
- < 10 mVrms
Ambient conditions
- Ambient temperature (operation)
- -20 °C - 70 °C
- Ambient temperature (storage/transport)
- -40 °C - 85 °C
- Maximum altitude
- ≤ 2000 m
- Degree of protection
- IP20 (not assessed by UL)
- Noise immunity
- EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
Environmental Product Compliance
- REACh SVHC
- Lead 7439-92-1
- China RoHS
- Environmentally Friendly Use Period = 50 years
- China RoHS
- For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration'
EMC data
- Designation
- Electromagnetic RF field
- Standards/regulations
- EN 61000-4-3
- Typical deviation from the measuring range final value
- 1.9 %
- Designation
- Fast transients (burst)
- Standards/regulations
- EN 61000-4-4
- Typical deviation from the measuring range final value
- 2 %
- Designation
- Conducted interferences
- Standards/regulations
- EN 61000-4-6
- Typical deviation from the measuring range final value
- 4.6 %
Standards and Regulations
- Electromagnetic compatibility
- Conformance with EMC directive
- Noise emission
- EN 61000-6-4
- Designation
- Electromagnetic RF field
- Standards/regulations
- EN 61000-4-3
- Standards/regulations
- EN 61000-4-4
- Designation
- Conducted interferences
- Standards/regulations
- EN 61000-4-6
- Conformance
- CE-compliant
- ATEX
- II 3 G Ex nA IIC T4 Gc
- IECEx
- Ex nA IIC T4 Gc
- UL, USA/Canada
- UL 61010 Listed
- UL, USA/Canada
- Class I, Div. 2, Groups A, B, C, D T4
- UL, USA/Canada
- Class I, Zone 2, Group IIC
- DNV GL-Temperature
- B
- DNV GL-Humidity
- B
- DNV GL-Vibration
- A
- DNV GL-EMC
- B
- DNV GL-Enclosure
- Required protection according to the Rules shall be provided upon installation on board
Power supply
- Supply voltage range
- 24 V - 230 V AC/DC (-20 %/+10 %, 50/60 Hz)
Andere Kategorien
NanometerManometerDurchflussmesserSensorenBeschleunigungssensorenLichtwellenleiter-SensorenDetektorenUltraschallsensorenTemperatur- und FeuchtigkeitssensorenSchwingungssensorenFüllstandssensorenDrucksensorenNäherungssensorenInduktive SensorenBewegungssensorenMagnetische Sensoren GruppeOptische SensorenKapazitive SensorenFotoelektrische SensorenPositionsgeberEncoderAndere Sensoren und Zubehör