Benötigen Sie weitere Informationen?
Rufen Sie uns an unter:+48 17 778 34 19
Schneider Electric 8502SFO2V02S
NEMA Contactor, Type S, nonreversing, Size 4, 135A, 100 HP at 575 VAC, 3 phase, up to 100 kA, 3 pole, 120 VAC coil, open
1 / 6
Produktbeschreibung
Lebenszyklus:
Type S non-reversing magnetic contactors are used to switch heating loads, capacitors, transformers, and electric motors where overload protection is provided separately. Type S contactors have ratings up to 810 amperes. This 3 pole NEMA Size 4 non-reversing contactor has a 135 ampere rating. Three phase NEMA Size 4 contactors have 40 HP at 200, 50 HP at 230 VAC and 100 HP at 460 and 575 VAC ratings. This NEMA contactor has a 100 kA maximum SCCR rating per UL508A when protected by an appropriate circuit breaker or fuse. These contactors are available with replaceable coils in a wide variety of voltages. This contactor has a 110/120 VAC 50/60 Hz coil that is wired for separate control. This NEMA contactor is an open device without an enclosure. This contactor is 8.19 inches tall, 6.00 inches wide and 6.50 inches deep. A wide variety of accessories are available for Type S contactors. Type S NEMA contactors are UL listed and CSA certified.
Anfrage senden
Zahlungsmethoden:
Angebotsdetails
- Bestes Angebot von:
Vertrauenswürdiger Lieferant — Rumänien, Mitglied seit 2023, 1–4 Mitarbeiter
- Verfügbarkeit:
- 1 Stk.Auf AnfrageAktualisiert am: 22-08-2026
- Zustand:
- Neuer Überschuss
Neuer Überschuss - Ein neuer, unbenutzter, unbeschädigter Artikel ohne Herstellergarantie. Der Artikel kann ohne Originalverpackung oder in Ersatzverpackung geliefert werden. Wenn vorhanden, könnte die Verpackung geöffnet worden sein.
Der Verkäufer ist verantwortlich für den Versand des Produkts und die Rechnungsstellung
Spezifikationen
- Marke
- Schneider Electric
- Warranty
- 18 months
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- China Rohs Regulation
- Product out of China RoHS scope. Substance declaration for your information.
- Eu Rohs Directive
- Not compliant
- Product Certifications
- UL listed file E78351 CCN NLDX || CSA
Auf unserer Plattform finden Sie weitere Angebote
Registrieren Sie sich jetzt, um 36 Mio. Angebote von verifizierten Anbietern weltweit zu entdecken.
- Angebote weltweit vergleichen
- Direkter Lieferantenkontakt
- RFQs, Angebote und Aufträge
- BOM-Suche
Sign UpKostenlose 14-tägige Testversion verfügbar
Dokumente
Datenblatt
Datenblatt für Schneider Electric 8502SFO2V02S, einschließlich Spezifikationen und Funktionen.
Datenblatt herunterladen
CAD Models
3D-CAD-Modell und technische Zeichnungen, bereit für Ihre Konstruktionssoftware.
CAD-Modell herunterladen
Einblicke in den Markt

Erhalten Sie Echtzeit-Analysen und Marktdaten, um Ihre Kaufentscheidungen für diese Komponente und ähnliche Produkte zu optimieren.
- Echtzeit-Verfügbarkeitsdaten von über 700 MRO-Händlern in Europa und den USA
- Preisanalyse nach Zustand (neu, gebraucht, überholt) mit Marktmedianpreisen
- Überwachung der Verfügbarkeit kritischer Komponenten zur Vermeidung von Produktionsausfällen
- Erkenntnisse zur Bestandsoptimierung auf der Grundlage von Marktangebotstrends

