Benötigen Sie weitere Informationen?

Rufen Sie uns an unter:+48 17 778 34 19

Schneider Electric 8911DPSG43V02

Starter, Definite Purpose, nonreversing, 40A, 3 pole, 3 phase, 120VAC coil, melting alloy overload, NEMA 1, +options

1 / 5
Schneider Electric 8911DPSG43V02 Starter, Definite Purpose, nonreversing, 40A, 3 pole, 3 phase, 120VAC coil, melting alloy overload, NEMA 1, +options — Allgemeines Zubehör
Katalogbild des Herstellers
Schneider Electric 8911DPSG43V02 Starter, Definite Purpose, nonreversing, 40A, 3 pole, 3 phase, 120VAC coil, melting alloy overload, NEMA 1, +options — Allgemeines Zubehör
Katalogbild des Herstellers
Schneider Electric 8911DPSG43V02 Starter, Definite Purpose, nonreversing, 40A, 3 pole, 3 phase, 120VAC coil, melting alloy overload, NEMA 1, +options — Allgemeines Zubehör
Katalogbild des Herstellers
Schneider Electric 8911DPSG43V02 Starter, Definite Purpose, nonreversing, 40A, 3 pole, 3 phase, 120VAC coil, melting alloy overload, NEMA 1, +options — Allgemeines Zubehör
Katalogbild des Herstellers
Schneider Electric 8911DPSG43V02 Starter, Definite Purpose, nonreversing, 40A, 3 pole, 3 phase, 120VAC coil, melting alloy overload, NEMA 1, +options — Allgemeines Zubehör
Katalogbild des Herstellers
Schneider Electric 8911DPSG43V02 Starter, Definite Purpose, nonreversing, 40A, 3 pole, 3 phase, 120VAC coil, melting alloy overload, NEMA 1, +options — Allgemeines Zubehör
Schneider Electric 8911DPSG43V02 Starter, Definite Purpose, nonreversing, 40A, 3 pole, 3 phase, 120VAC coil, melting alloy overload, NEMA 1, +options — Allgemeines Zubehör
Schneider Electric 8911DPSG43V02 Starter, Definite Purpose, nonreversing, 40A, 3 pole, 3 phase, 120VAC coil, melting alloy overload, NEMA 1, +options — Allgemeines Zubehör
Schneider Electric 8911DPSG43V02 Starter, Definite Purpose, nonreversing, 40A, 3 pole, 3 phase, 120VAC coil, melting alloy overload, NEMA 1, +options — Allgemeines Zubehör
Schneider Electric 8911DPSG43V02 Starter, Definite Purpose, nonreversing, 40A, 3 pole, 3 phase, 120VAC coil, melting alloy overload, NEMA 1, +options — Allgemeines Zubehör

Produktbeschreibung

Lebenszyklus:
8911 definite purpose starters are inexpensive starters for applications with relatively low duty cycles. Typical applications include air compressors, agricultural equipment, pumps, and HVAC equipment. This three pole definite purpose starter has a full load rating of 40 amperes. This starter has ratings of 3 HP at 115 VAC and 7.5 HP at 230 VAC single phase. It also has a rating of 10 HP at 230 VAC, 20 HP at 460 VAC and 25 HP at 575 VAC poly phase. The nonreplaceable coil is available with a variety of coil voltages. This device has a 110/120 VAC 50/60 Hz coil. The starter has straight through wiring. The melting alloy type overload relay uses Type B thermal units to sense over current conditions. A painted sheet steel NEMA 1 general purpose enclosure is used to protect this definite purpose starter. Enclosure is 10.00 inches tall, 6.00 inches wide and 5.56 inches deep. Auxiliary contacts are available for these starters. 8911DPS definite purpose starters are UL component recognized.
  • Erhalten Sie bis zu 90 Tage Zahlungsziele von 500+ Lieferanten
  • Wiederverkaufsrabatte bis zu 40%!
Sign Up
Preisanfrage senden
Anfrage senden
Zahlungsmöglichkeiten:
Fordern Sie ein Angebot an und wir senden Ihnen Informationen zu Verfügbarkeit und Preis.

Spezifikationen

China Rohs Regulation
Product out of China RoHS scope. Substance declaration for your information.
Rohs Exemption Information
Yes
Mercury Free
Yes
Eu Rohs Directive
Compliant with Exemptions
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
Thermal Overload Type
melting alloy

Auf unserer Plattform finden Sie weitere Angebote

Registrieren Sie sich jetzt, um 36 Mio. Angebote von verifizierten Anbietern weltweit zu entdecken.

  • Angebote weltweit vergleichen
  • Direkter Lieferantenkontakt
  • RFQs, Angebote und Aufträge
  • BOM-Suche
Sign UpKostenlose 14-tägige Testversion verfügbar

Dokumente

Datenblatt

Datenblatt für Schneider Electric 8911DPSG43V02, einschließlich Spezifikationen und Funktionen.

Datenblatt herunterladen
TracePartsTraceParts

CAD Models

3D-CAD-Modell und technische Zeichnungen, bereit für Ihre Konstruktionssoftware.

CAD-Modell herunterladen

Kompatible Produkte

8911DPB1 Schneider Electric
8911DPB1
Schneider Electric
Starter, Definite Purpose, nonreversing, start stop push button kit
9998SO31 Schneider Electric
9998SO31
Schneider Electric
NEMA Motor Starter, Type S, melting alloy overload relay jumper strap

Einblicke in den Markt

AutomaINSIGHTS Analyse-Dashboard

Erhalten Sie Echtzeit-Analysen und Marktdaten, um Ihre Kaufentscheidungen für diese Komponente und ähnliche Produkte zu optimieren.

  • Echtzeit-Verfügbarkeitsdaten von über 700 MRO-Händlern in Europa und den USA
  • Preisanalyse nach Zustand (neu, gebraucht, überholt) mit Marktmedianpreisen
  • Überwachung der Verfügbarkeit kritischer Komponenten zur Vermeidung von Produktionsausfällen
  • Erkenntnisse zur Bestandsoptimierung auf der Grundlage von Marktangebotstrends
Starten

Andere Kategorien