Regulated Power Supply, 100 to 240V AC, 24V, 3.8A, single phase, Optimized
ABLS1A24038
  • Erhalten Sie bis zu 90 Tage Zahlungsziele von 500+ Lieferanten
  • Wiederverkaufsrabatte bis zu 40%!
Sign-Up
Preisanfrage senden
1
Zahlungsmöglichkeiten:
Insgesamt 27 Parts In-Stock von 17 Distributors
Angebot mit Herstellervorlaufzeit
Lieferung:1 - 2 Viele Arbeitstage
Bester Preis:
€43.74

Additional Information

Part Number
ABLS1A24038
UNSPSC
39121004
Tariff Code
8504409520
Country of Origin
TH

Specifications

Range Of Product
Modicon Power Supply
Output Voltage
24 V DC
Product Or Component Type
power supply
Power Supply Type
regulated switch mode
Input Voltage
100...240 V AC single phase || 100...240 V AC phase to phase
Power Supply Output Current
3.8 A
Kw Rating
91.2 W
Enclosure Material
Plastic

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP2001002EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Circularity Profile
ENVEOLI2001002EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Complementary

Output Coupling
serial
Height
75 mm
Residual Ripple
< 75 mV
Status Led
1 LED (Green) output voltage
Holding Time
> 20 ms 100 V AC || > 50 ms 230 V AC
Efficiency At Full Load
85...264 V AC
Earthing System
TN || TT || IT
Connections - Terminals
screw connection 0.5...2.5 mm², AWG 20...AWG 14) input/output
Dielectric Strength
3000 V AC with input to output
Network Frequency Limits
50-60 Hz
Current Consumption
< 1.2 A 115 V AC || < 0.6 A 230 V AC
Supply
SELV IEC 60950-1 || SELV IEC 60204-1 || SELV IEC 60364-4-41
Net Weight
0.325 kg
Maximum Leakage Current
1 mA 240 V AC
Input Protection Type
integrated fuse (not interchangeable) 3.15 A || external protection (recommended) 20 A Curve C || external protection (recommended) 10 A Curve B || external protection (recommended) 6 A Curve C
Output Protection Type
against overload and short-circuits automatic reset || against over temperature manual reset || against overvoltage manual reset
Service Life
10 year(s)
Meantime Between Failure [Mtbf]
1500000 h at 25 °C, full load conforming to SR 332 || 600000 h at 55 °C, 80 % load conforming to SR 332
Power Dissipation In W
13 W
Output Voltage Limits
24 V
Mounting Support
top hat type TH35-15 rail IEC 60715 || top hat type TH35-7.5 rail IEC 60715 || double-profile DIN rail
Load Capacitance
3000 µF
Response Time
< 3 s
Line And Load Regulation
< 1 % network 0 to 100 % load at 25 °C || < 2 % network full voltage range in line at 25 °C
Width
45 mm
Overvoltage Category
II
Inrush Current
45.0 A 115 V || 70.0 A 230 V
Efficiency
87 % 115 V AC || 89 % 230 V AC
Depth
100 mm
Power Factor
0.90 at 115 V AC || 0.85 at 230 V AC

Environment

Standards
IEC 62368-1 || EN/IEC 61204-3 || IEC 61000-6-1 || IEC 61000-6-2 || IEC 61000-6-3 || IEC 61000-6-4 || IEC 61000-3-2 || EN 61000-3-3 || UL 62368-1 || CSA C22.2 No 62368-1 || UL 508 || CSA C22.2 No. 107.1 || EN/IEC 62368-1
Ambient Air Temperature For Operation
-20--10 °C with current derating of 2 % per °C mounting position A < 6561.68 ft (2000 m) || -10-55 °C without derating mounting position A < 6561.68 ft (2000 m) || 55-70 °C with current derating of 3.33 % per °C mounting position A < 6561.68 ft (2000 m)
Product Certifications
CE || cUL Listed || cUL Recognized || RCM || CB Scheme || EAC || KC || NEC class 2
Pollution Degree
2
Electromagnetic Compatibility
immunity to electrostatic discharge - test level: 8 kV (contact discharge) conforming to IEC 61000-4-2 || immunity to electrostatic discharge - test level: 15 kV (air discharge) conforming to IEC 61000-4-2 || immunity to conducted RF disturbances - test level: 15 V/m (80 MHz...2 GHz) conforming to IEC 61000-4-3 || immunity to conducted RF disturbances - test level: 5 V/m (2...2.7 GHz) conforming to IEC 61000-4-3 || immunity to conducted RF disturbances - test level: 5 V/m (2.7...6 GHz) conforming to IEC 61000-4-3 || immunity to fast transients - test level: 4 kV (on input-output) conforming to IEC 61000-4-4 || surge immunity test - test level: 4 kV (between power supply and earth) conforming to IEC 61000-4-5 || surge immunity test - test level: 3 kV (between phases) conforming to IEC 61000-4-5 || immunity to conducted RF disturbances - test level: 15 V (0.15...80 MHz) conforming to IEC 61000-4-6 || immunity to magnetic fields - test level: 30 A/m (50...60 Hz) conforming to IEC 61000-4-8 || immunity to voltage dips conforming to IEC 61000-4-11 || disturbing field emission conforming to EN 55016-2-3 || limits for harmonic current emissions conforming to IEC 61000-3-2 || conforming to EN 55016-1-2 || conforming to EN 55016-2-1
Shock Resistance
150 m/s² 11 ms
Vibration Resistance
3 mm 2-9 Hz)IEC 60068-2-6 || 10 m/s² 9-200 Hz)IEC 60068-2-6
Ip Degree Of Protection
IP20
Operating Altitude
< 6561.68 ft (2000 m)
Electrical Shock Protection Class
class I
Electromagnetic Emission
conducted emissions IEC 61000-6-3 || radiated emissions IEC 61000-6-4

Dokumente

Data Sheet

Herunterladen

CAD Models

Trace parts
Trace parts
Herunterladen

Ähnliche Produkte