Contactor body,TeSys F,3P(3NO)-AC-3, <=440V 265A without coil
LC1F265
  • Erhalten Sie bis zu 90 Tage Zahlungsziele von 500+ Lieferanten
  • Wiederverkaufsrabatte bis zu 40%!
Sign-Up
$1,186.68
1
Zahlungsmöglichkeiten:
Insgesamt 38 Parts In-Stock von 24 Distributors
Angebot mit Herstellervorlaufzeit
Lieferung:1 - 2 Viele Arbeitstage
Bester Preis:
€454.93

Additional Information

Part Number
LC1F265
UNSPSC
39121529
Tariff Code
8536490065
Country of Origin
CZ

Environment

Mechanical Robustness
vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed5 Gn, 5...300 Hz || shocks contactor open6 Gn for 1/2 sine wave (11 ms) || shocks contactor closed15 Gn for 1/2 sine wave (11 ms)
Ambient Air Temperature For Operation
-5-55 °C
Height
203 mm
Net Weight
8.54 kg
Ambient Air Temperature For Storage
-60-80 °C
Protective Treatment
TH
Ip Degree Of Protection
IP20 front face with shrouds IEC 60529 || IP20 front face with shrouds VDE 0106
Operating Altitude
9842.52 ft (3000 m) without derating
Width
201.5 mm
Depth
213 mm
Permissible Ambient Air Temperature Around The Device
-40-70 °C

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP080208EN
Sustainable Offer Status
Green Premium product
Pvc Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile
ENVEOLI100418
Eu Rohs Directive
Compliant with Exemptions

Complementary

Product Certifications
ABS || CB || DNV || RMRoS || UL || CSA || RINA || LROS (Lloyds register of shipping) || BV || UKCA
Power Dissipation Per Pole
37 W AC-1 || 21 W AC-3
Average Impedance
0.3 mOhm - Ith 350 A 50 Hz
Control Circuit Voltage Limits
operational: 0.85...1.1 Uc AC 40...400 Hz with LX1/LX9 coil || drop-out: 0.35...0.55 Uc AC 40...400 Hz with LX1/LX9 coil || operational: 0.85...1.1 Uc DC with LX4 coil || drop-out: 0.15...0.2 Uc DC with LX4 coil || operational: 85...275 V AC 50/60 Hz with LXE coil || drop-out: 0...60 V AC 50/60 Hz with LXE coil || operational: 85...418 V DC with LXE coil || drop-out: 0...45 V DC with LXE coil
[Ith] Conventional Free Air Thermal Current
350 A (at 40 °C)
Standards
IEC 60947-1 || IEC 60947-4-1 || JIS C8201-4-1 || EN 60947-1 || EN 60947-4-1
[Ue] Rated Operational Voltage
<= 1000 V AC-1 || <= 690 V AC-3 || <= 690 V AC-4 || <= 460 V DC
[Uc] Control Circuit Voltage
24...1000 V AC 40...400 Hz with LX1/LX9 coil || 24...460 V DC with LX4 coil || 100...250 V AC 50/60 Hz with LXE coil || 100...380 V with LXE coil
Mounting Support
plate
Rated Breaking Capacity
2120 A conforming to IEC 60947-4-1
Irms Rated Making Capacity
2650 A AC conforming to IEC 60947-4-1
Associated Fuse Rating
315 A aM at <= 440 V || 400 A gG at <= 440 V
[Uimp] Rated Impulse Withstand Voltage
8 kV
Connections - Terminals
power circuit bar 2 32 x 4 mm || power circuit lugs-ring terminals 1 240-240 mm² || power circuit connector 1 240-240 mm² || power circuit bolted connection || control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible with cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm²solid without cable end || control circuit screw clamp terminals 1 1-4 mm² || control circuit screw clamp terminals 2 1-4 mm² || control circuit screw clamp terminals 1.0 0.2-2.5 mm²flexible without cable end || control circuit screw clamp terminals 1.0 0.25-2.5 mm²flexible with cable end || control circuit screw clamp terminals 1.0 0.2-2.5 mm²solid without cable end
Inrush Power In Va
600-700 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil || 655-803 VA (at 20 °C)with LX4 coil || 300-350 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil || 300-310 VA (at 20 °C)with LXE coil
Maximum Operating Rate
2400 cyc/h 55 °C
Operating Time
40...65 ms closing with LX1/LX9 coil || 100...170 ms opening with LX1/LX9 coil || 40...50 ms closing with LX4 coil || 40...65 ms opening with LX4 coil || 40...80 ms closing with LXE coil || 6...54 ms opening with LXE coil
Tightening Torque
power circuit 35 N.m || control circuit 1.2 N.m || control circuit 0.6 N.m
Mechanical Durability
10 Mcycles
Compatibility Code
LC1F
Hold-In Power Consumption In Va
8-10 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil || 3.68-4.53 VA (at 20 °C)with LX4 coil || 4.5-7.0 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil || 2.5-4.0 VA (at 20 °C)with LXE coil
Overvoltage Category
III
[Ui] Rated Insulation Voltage
1000 V IEC 60947-4-1 || 1500 V VDE 0110 group C
[Icw] Rated Short-Time Withstand Current
2200 A 40 °C - 10 s || 1230 A 40 °C - 30 s || 950 A 40 °C - 1 min || 620 A 40 °C - 3 min || 480 A 40 °C - 10 min
Heat Dissipation
8-8 W || 2.2-2.5 W

Specifications

Contactor Application
resistive load || motor control
Product Or Component Type
contactor
Product Name
TeSys F
Range
TeSys
Pole Contact Composition
3 NO
[Ie] Rated Operational Current
350 A 40 °C) <= 440 V AC AC-1 || 265 A 55 °C) <= 440 V AC AC-3
Utilisation Category
AC-3 || AC-4 || AC-1
Poles Description
3P
Motor Power Kw
132 kW at 380...400 V AC 50/60 Hz (AC-3) || 140 kW at 415 V AC 50/60 Hz (AC-3) || 140 kW at 440 V AC 50/60 Hz (AC-3) || 147 kW at 1000 V AC 50/60 Hz (AC-3) || 160 kW at 500 V AC 50/60 Hz (AC-3) || 75 kW at 220...240 V AC 50/60 Hz (AC-3) || 160 kW at 660...690 V AC 50/60 Hz (AC-3) || 51 kW at 400 V AC 50/60 Hz (AC-4)
Device Short Name
LC1F

Dokumente

Data Sheet

Herunterladen

CAD Models

Trace parts
Trace parts
Herunterladen

Ähnliche Produkte