Schneider Electric
LV426952
1 / 1
Beschreibung
It is a pre-wired auxiliary contact that provides remote information of the circuit breaker status. It is used on Compact NSXm and PowerPact B devices. SD contact indicates that the circuit breaker has tripped. This auxiliary is a common point changeover type contact with 1 normally open contact and 1 normally closed contact. The rated current is 5A and the minimum load is 2mA at 17 VDC. Utilization categories are AC12/AC13/DC12/DC13/DC14. Compact NSXm embeds 2 auxiliary contacts and their presence is visible on the front face through green flags. It complies with IEC 60947-5-1 standard.- Country of Origin
- CN
- Part Number
- LV426952
- Tariff Code
- 85389099
- EAN
- 3606485444239
- UNSPSC
- 39121522
- Erhalten Sie bis zu 90 Tage Zahlungsziele von 500+ Lieferanten
- Wiederverkaufsrabatte bis zu 40%!
Preisanfrage senden
1
Zahlungsmöglichkeiten:
Specifications
- Range Compatibility
- PowerPact (PowerPact B) || ComPact (ComPact NSXm)
- Product Or Component Type
- auxiliary contact
- Signal Contacts Composition
- 1 NO/NC
- Device Application
- breaker status monitoring
- Device Short Name
- SD
Complementary
- Fault Type
- overload || short-circuit
- Auxiliary Connection Terminal
- pre-wired 0.8-0.8 mm² AWG 18)stranded copper
- [Ith] Conventional Free Air Thermal Current
- 5 A
- Wire Stripping Length
- 8 mm front
- Mounting Mode
- clip-on
- Auxiliary Contacts Type
- standard
- [Ie] Rated Operational Current
- AC-12: 5 A at 24 V AC 50/60 Hz || AC-12: 5 A at 48 V AC 50/60 Hz || AC-12: 5 A at 110...127 V AC 50/60 Hz || AC-12: 5 A at 220/240 V AC 50/60 Hz || AC-12: 5 A at 380/440 V AC 50/60 Hz || AC-12: 5 A at 660/690 V AC 50/60 Hz || AC-15: 5 A at 24 V AC 50/60 Hz || AC-15: 5 A at 48 V AC 50/60 Hz || AC-15: 4 A at 110...127 V AC 50/60 Hz || AC-15: 3 A at 220/240 V AC 50/60 Hz || AC-15: 2.5 A at 380/440 V AC 50/60 Hz || AC-15: 0.1 A at 660/690 V AC 50/60 Hz || DC-12: 5 A at 24 V DC 50/60 Hz || DC-12: 2.5 A at 48 V DC 50/60 Hz || DC-12: 0.6 A at 110 V DC 50/60 Hz || DC-12: 0.3 A at 250 V DC 50/60 Hz || DC-13: 2.5 A at 24 V DC 50/60 Hz || DC-13: 1.2 A at 48 V DC || DC-13: 0.35 A at 110 V DC || DC-13: 0.05 A at 250 V DC || DC-14: 1 A at 24 V DC || DC-14: 0.2 A at 48 V DC || DC-14: 0.05 A at 110 V DC || DC-14: 0.03 A at 250 V DC
- Local Signalling
- for relay trip indicator trip indicator
- Minimum Load
- 2 mA 17 V DC
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP110804EN
- Sustainable Offer Status
- Green Premium product
- Toxic Heavy Metal Free
- Yes
- Reach Regulation
- Free of Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Reach Free Of Svhc
- Yes
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Circularity Profile
- ENVEOLI111011EN
- Eu Rohs Directive
- Compliant