Schneider Electric
QDL32100
1 / 8
Beschreibung
Aktiv Reif
PowerPacT Q-Frame circuit breakers are used for overcurrent protection and switching on 240VAC systems. They are rated for 240VAC operational voltage and provide thermal magnetic trip protection. PowerPacT Q circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. This unit has lugs on both the line and load sides. This PowerPacT Q, 100A, 3 pole, circuit breaker has an interrupting rating of 25kA at 208Y/120VAC and 240VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT Q circuit breakers comply to UL, CSA, and NOM standards and are IEC certified.- Country of Origin
- MX
- Part Number
- QDL32100
- Tariff Code
- 8536200020
- EAN
- 39121616
- UPC
- 785901662402
- UNSPSC
- 39121616
Zahlungsmethoden:
- Bestes Angebot von:
- Vertrauenswürdiger Automa.Net Lieferant
- Verfügbarkeit:
- 16 Stk.Auf LagerAktualisiert am: 09-11-2024
- Geschätzte Lieferung:
- Auf Anfrage
- Zustand:
- Neuer Überschuss
Neuer Überschuss - Ein neuer, unbenutzter, unbeschädigter Artikel ohne Herstellergarantie. Der Artikel kann ohne Originalverpackung oder in Ersatzverpackung geliefert werden. Wenn vorhanden, könnte die Verpackung geöffnet worden sein.
Sicherer Zahlungsprozess
Rückgabe- und Erstattungsrichtlinien
Versandrichtlinien
Garantiebedingungen
Environment
- Ambient Air Temperature For Operation
- 40-70 °C
- Standards
- UL || CSA || NEMA || NOM-003-SCFI-2000
- Product Certifications
- UL || CSA || NOM
Contractual warranty
- Warranty
- 18 months
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP1406032EN
- Sustainable Offer Status
- Green Premium product
- Pvc Free
- Yes
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- China Rohs Regulation
- Product out of China RoHS scope. Substance declaration for your information.
- Circularity Profile
- N/A
- Eu Rohs Directive
- Compliant with Exemptions
- Halogen Content Performance
- Halogen free product
Complementary
- Mounting Mode
- unit mount lug)
- Network Frequency
- 50/60 Hz
- Trip Unit Technology
- thermal-magnetic
- Height
- 6.47 in
- [Ue] Rated Operational Voltage
- 240 V AC 50/60 Hz UL
- Tightening Torque
- 28-28 N.m 25-150 mm² (AWG 4...300 kcmil)
- Mounting Support
- lug
- Breaking Capacity Code
- D
- Magnetic Tripping Current
- 2400-2400 A
- Local Signalling
- 1 trip indicator green)
- Electrical Connection
- lugs, load || lugs, line
- [Uimp] Rated Impulse Withstand Voltage
- 8 kV UL
- Magnetic Hold Current
- 1200 A
- Control Type
- operating handle
- Circuit Breaker Application
- HACR rated
- Wire Stripping Length
- 22 mm
- Utilisation Category
- category A
- Line Rated Current
- 100-100 A
- Continuous Current Rating
- 80 %
- Breaking Capacity
- 25 kA 120/208 V AC 50/60 Hz UL || 25 kA 240 V AC 50/60 Hz UL
- Mechanical Durability
- 1000 cycles loaded || 5000 cycles no load
- Poles Description
- 3P
- Line Rated Current
- 100 A
- Width
- 4.5 in
- Depth
- 3.93 in
Specifications
- Product Or Component Type
- circuit breaker
- Product Name
- PowerPact Q
- Range
- PowerPact
- Device Application
- distribution
Dokumente
Data Sheet
HerunterladenAndere Kategorien
AktuatorenBlöckeKabel, Rohre & SchläucheKompressorenKontrolleKupplungen & FittingsZylinder & KolbenElektronikFilterHVACIndustrie-PCs & HMIsBeleuchtungLineartechnikMotorenStromversorgungLeistungsübertragungPumpen & VentileErneuerbare energieRobotikDichtungen, Ringe & VerbinderSensoren und MessgeräteWerkzeuge und ZubehörCNCSonstiges