Schneider Electric RMCL55BD

Voltage or current converter, Harmony Analog, Isolated 0...20mA

1 / 1
Schneider Electric RMCL55BD Voltage or current converter, Harmony Analog, Isolated 0...20mA — Industrietransformatoren & Wandler
Katalogbild des Herstellers

Produktbeschreibung

Lebenszyklus:
This voltage/current converter is part of the range of Harmony Analog. It allows conversion of the most common signals. Its supply voltage is 24V DC, isolated. It features four inputs with voltage/current range of 0V to 10V, +/- 10V, 0mA to 20mA, and 4mA to 20mA. It has four outputs with a switchable voltage/current range of 0V to 10V, +/- 10V, 0mA to 20mA, and 4mA to 20mA. It also allows the connection distance between a sensor and the measurement acquisition device to be increased. 0 It weighs 0.120Kg. 0 0 Conforming to IEC standards, UL and CSA certified, this converter is suitable for universal use. 0 0 0 0 Quick and intuitive setting, easy to use with fixed input and output values according to the market needs. The settings are secure with sealable protective cover. 0
Anfrage senden
Zahlungsmethoden:

Angebotsdetails

Bestes Angebot von:
Vertrauenswürdiger Lieferant — Rumänien, Mitglied seit 2023, 1–4 Mitarbeiter
Verfügbarkeit:
1 Stk.
Auf Anfrage
Aktualisiert am: 22-08-2026
Zustand:
Neuer Überschuss
Neuer Überschuss - Ein neuer, unbenutzter, unbeschädigter Artikel ohne Herstellergarantie. Der Artikel kann ohne Originalverpackung oder in Ersatzverpackung geliefert werden. Wenn vorhanden, könnte die Verpackung geöffnet worden sein.
Der Verkäufer ist verantwortlich für den Versand des Produkts und die Rechnungsstellung

Spezifikationen

Product Certifications
UL || GL || CSA
Standards
IEC 60947-1 || IEC 60584-1
Ambient Air Temperature For Operation
0-50 °C mounting side by side || 0-60 °C 2 cm spacing
Shock Resistance
50 gn 11 ms IEC 60068-2-27
Vibration Resistance
5 gn 10-100 Hz)IEC 60068-2-6
Ip Degree Of Protection
IP20 terminal block) || IP50 housing)

Verfügbare Angebote

(2)
RMCL55BD Schneider Electric, Industrietransformatoren & Wandler

Schneider Electric

Verfügbar:
0 Stk.
Auf Anfrage
Aktualisiert am: 11-09-2026
Angebot von:
Vertrauenswürdiger Lieferant — Deutschland, Mitglied seit 2024

Auf unserer Plattform finden Sie weitere Angebote

Registrieren Sie sich jetzt, um 36 Mio. Angebote von verifizierten Anbietern weltweit zu entdecken.

  • Angebote weltweit vergleichen
  • Direkter Lieferantenkontakt
  • RFQs, Angebote und Aufträge
  • BOM-Suche
Sign UpKostenlose 14-tägige Testversion verfügbar
Angebot mit Herstellervorlaufzeit
Direkt vom Hersteller - mit einer bestätigten, vorhersehbaren und völlig transparenten Lieferzeit.
Get Quote

Dokumente

Datenblatt

Datenblatt für Schneider Electric RMCL55BD, einschließlich Spezifikationen und Funktionen.

Datenblatt herunterladen
TracePartsTraceParts

CAD Models

3D-CAD-Modell und technische Zeichnungen, bereit für Ihre Konstruktionssoftware.

CAD-Modell herunterladen

Kompatible Produkte

RMCA61BD Schneider Electric
RMCA61BD
Schneider Electric
This voltage/current converter is part of the Harmony Analog range
RMCN22BD Schneider Electric
RMCN22BD
Schneider Electric
This voltage/current converter is part of the range of Harmony Analog interfaces
RMCV60BD Schneider Electric
RMCV60BD
Schneider Electric
This voltage/current converter is part of the range of interfaces Harmony Analog

Ähnliche Produkte

6SL3210-1KE13-2AF2 Siemens
6SL3210-1KE13-2AF2
Siemens
SINAMICS G120C Rated Power 1.1KW with 150% overload for 3 seconds, 3AC380-480V +10/-20%, 47-63Hz, integrated filter class A I/O interface: 6DI, 2DO, 1AI, 1AO, safe torque off, integrated fieldbus PROFINET-PN protection IP20/ UL open type size FSAA 17
XPS-375-CONT Brady Corporation
XPS-375-CONT
Brady Corporation
IDXPERT Series PermaSleeve Polyolefin Wire Marking Sleeves, 0.375" Dia x 8' L
LR2K0310 Schneider Electric
LR2K0310
Schneider Electric
TeSys LRK thermal overload relay, 3
3VA1225-4EF32-0AA0 Siemens
3VA1225-4EF32-0AA0
Siemens
circuit breaker 3VA1 IEC frame 250 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=250A overload protection Ir=175A...250A short-circuit protection Ii=5...10 x In nut keeper kit
3VA1112-3EE46-0AA0 Siemens
3VA1112-3EE46-0AA0
Siemens
circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 4-pole, line protection TM220, ATFM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=10 x In N conductor unprotected clamp connection
MER1S0505SC Murata
MER1S0505SC
Murata
Efficient and compact 1W DC-DC converter with 1kVDC isolation, ideal for various electronic applications.
LA9D8069 Schneider Electric
LA9D8069
Schneider Electric
TeSys D set of power connections, for 3-pole contactors LC1D80, LP1D80, LC1D95
6SL3210-1KE18-8UB1 Siemens
6SL3210-1KE18-8UB1
Siemens
SINAMICS G120C Rated Power 4.0KW with 150% Overload for 3 Sec, 3AC380-480V +10/-20%, 47-63HZ Unfiltered I/O-Interface: 6DI, 2DO,1AI,1AO Safe Torque Off Integrated Fieldbus: USS/ Modbus RTU Protection: IP20/ UL Open Type Size: FSA 196X73X203(HXWXD) Ex
6SL3210-1SE12-2UA0 Siemens
6SL3210-1SE12-2UA0
Siemens
SINAMICS S120 PM340: 380-480V 3AC input, 0.75kW (2.2A) output power module. Blocksize FSA frame, internal air cooling.
6SL3210-1KE18-8AF1 Siemens
6SL3210-1KE18-8AF1
Siemens
SINAMICS G120C with a rated power of 4.0KW and an overload capacity of 150% for 3 seconds, operating at 3AC, 380-480V with +10/-20% voltage variation, and a frequency range of 47-63Hz.
2910124 Phoenix Contact
2910124
Phoenix Contact
Primary-switched DC/DC converter, QUINT POWER, DIN rail mounting, SFB Technology (Selective Fuse Breaking),- 12 V DC, output: 24 V DC / 5 A
1046881 Phoenix Contact
1046881
Phoenix Contact
Primary-switched DC/DC converter, QUINT POWER, DIN rail mounting, SFB Technology (Selective Fuse Breaking),- 24 V DC, output: 24 V DC / 20 A

Einblicke in den Markt

AutomaINSIGHTS Analyse-Dashboard

Erhalten Sie Echtzeit-Analysen und Marktdaten, um Ihre Kaufentscheidungen für diese Komponente und ähnliche Produkte zu optimieren.

  • Echtzeit-Verfügbarkeitsdaten von über 700 MRO-Händlern in Europa und den USA
  • Preisanalyse nach Zustand (neu, gebraucht, überholt) mit Marktmedianpreisen
  • Überwachung der Verfügbarkeit kritischer Komponenten zur Vermeidung von Produktionsausfällen
  • Erkenntnisse zur Bestandsoptimierung auf der Grundlage von Marktangebotstrends
Starten