- [Us] Rated Supply Voltage
- 100...120 V - 15...10 % || 200...230 V - 15...10 %
- Maximum Mechanical Speed
- 3000 rpm
- Height
- 145 mm
- Maximum Switching Current
- 50 mA 24 V output signals)
- Physical Interface
- RS422 - pulse/direction interface || RS422 - signal input ENC_A, ENC_B, ENC_I
- Inrush Current
- 60 A
- Output Voltage
- <= 30 V 24 V output signals) || 4.75...5.25 V ENC+5V_OUT signal output)
- Maximum Motor Phase Current
- 6.8 A
- Maximum Voltage Drop
- <1 V 50 mA load 24 V output signals
- Format Of The Drive
- block
- Shock Resistance
- 15 gn 11 ms IEC 60068-2-27
- Supply Voltage Type
- AC/DC
- Input Current
- 10 mA 24 V input signals
- Current Consumption
- 5 A 230 V main supply || 7 A 115 V main supply || <= 0.2 mA 24 V control voltage
- Residual Ripple
- < 5 % 24 V control voltage)
- Phase
- single phase
- Net Weight
- 1.2 kg
- Maximum Leakage Current
- 30 mA <10 m IEC 60990-3
- Voltage State 0 Guaranteed
- -3...5 V 24 V input signals
- Communication Interface
- Profibus DP fieldbus, Integrated
- Voltage State 1 Guaranteed
- 15...30 V 24 V input signals
- Associated Fuse Rating
- 10 A 115 V || 6 A 230 V
- Maximum Input Frequency
- 200 kHz signal input ENC_A, ENC_B, ENC_I pulse/direction || 400 kHz signal input ENC_A, ENC_B, ENC_I A/B
- Short-Circuit Current
- 0.5 kA
- Network Frequency Limits
- 50-60 Hz - 15...10 %)
- Type Of Cooling
- fan
- Safety Function
- safe torque off safety function machine IEC/EN 61800-5-2 || safe torque off safety function machine ISO 13849-1 level d || safe torque off safety function system process EN/IEC 61508 level SIL2 || safe torque off safety function system process IEC/EN 61800-5-2
- Resistance
- 5 kOhm pulse/direction interface)
- Maximum Output Frequency
- 400 kHz pulse/direction interface A/B || 200 kHz pulse/direction interface pulse/direction
- Width
- 72 mm
- Overvoltage Category
- III
- Nominal Power
- 280 W 115 V || 420 W 230 V
- Depth
- 140 mm
- Power Losses
- <= 65 W
- Input Voltage
- 24 V -15 %/+20 % 24 V control voltage