Schneider Electric
XALK178
1 / 6
Beschreibung
Aktiv Reif
This Harmony XALK yellow (RAL1021) control station is ideal for a clearly visible emergency shutdown of any machine. This yellow control station enables machine builders to easily add control and signalling functionality on their machines, with permanent modifications or damage to their machine body. It is designed for simple and mass production machines, textiles, packaging, handling small lifting systems, control of garage doors, rolling shutters, smoke extraction vents. It offers emergency stop and emergency switching off functions. It is impact resistant, dust resistant, water resistant, corrosion resistant, and vibration resistant thanks to its IP69 / IP67 / IP66 / IP69K, making it ideal for operation in harsh environments.- Country of Origin
- CZ
- Part Number
- XALK178
- Tariff Code
- 85365080
- EAN
- 3389119027892
- UNSPSC
- 39122216
Zahlungsmethoden:
- Bestes Angebot von:
- Vertrauenswürdiger Automa.Net Lieferant
- Verfügbarkeit:
- 3 Stk.Auf LagerAktualisiert am: 09-11-2024
- Garantie:
- 12 Monate
- Geschätzte Lieferung:
- Auf Anfrage
- Zustand:
- Neu versiegelt ab Werk
Neu versiegelt ab Werk - Ein brandneuer, unbenutzter, ungeöffneter, unbeschädigter Artikel in seiner original vom Hersteller versiegelten Verpackung.
Sicherer Zahlungsprozess
Rückgabe- und Erstattungsrichtlinien
Versandrichtlinien
Garantiebedingungen
Environment
- Ik Degree Of Protection
- IK03 IEC 62262
- Ambient Air Temperature For Operation
- -40-70 °C
- Standards
- IEC 60204-1 || IEC 60947-1 || IEC 60947-5-4 || ISO 13850 || JIS C 4520 || IEC 60364-5-53 || IEC 60947-5-5 || UL 508 || CSA C22.2 No 14 || IEC 60947-5-1
- Shock Resistance
- 30 gn 18 ms) half sine wave acceleration IEC 60068-2-27 || 50 gn 11 ms) half sine wave acceleration IEC 60068-2-27
- Vibration Resistance
- 5 gn 12-500 Hz)IEC 60068-2-6
- Ip Degree Of Protection
- IP66 IEC 60529 || IP67 || IP69 || IP69K
- Ambient Air Temperature For Storage
- -40-70 °C
- Overvoltage Category
- class II IEC 60536
- Nema Degree Of Protection
- NEMA 13 || NEMA 4X
- Protective Treatment
- TH
Contractual warranty
- Warranty
- 18 months
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP1806010EN
- Sustainable Offer Status
- Green Premium product
- Toxic Heavy Metal Free
- Yes
- Reach Regulation
- Free of Substances of Very High Concern above the threshold
- Reach Free Of Svhc
- Yes
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation
- X
- Circularity Profile
- ENVEOLI1806010EN
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
Complementary
- Operating Force
- 44 N NC + NO changing electrical state
- Short-Circuit Protection
- 10 A cartridge fuse gG IEC 60947-5-1
- Operating Travel
- 1.5 mm NC changing electrical state) || 2.6 mm NO changing electrical state) || 4.3 mm total travel)
- Contacts Material
- silver alloy (Ag/Ni)
- Positive Opening
- with IEC 60947-5-1 appendix K
- [Ith] Conventional Free Air Thermal Current
- 10 A IEC 60947-5-1
- Cable Entry
- 1 knock-out for cable entry 0-14 mm || 2 knock-outs for Pg 13 cable gland and ISO M20 0-12 mm
- Net Weight
- 0.194 kg
- [Uimp] Rated Impulse Withstand Voltage
- 6 kV IEC 60947-1
- Resistance To High Pressure Washer
- 7000000 Pa 55 °C 0.1 m
- Electrical Durability
- 1000000 cycles, AC-15, 2 A 230 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, AC-15, 3 A 120 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, AC-15, 4 A 24 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, DC-13, 0.2 A 110 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, DC-13, 0.5 A 24 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C
- Connections - Terminals
- screw clamp terminals, <= 2 x 1.5 mm² with cable end IEC 60947-1 || screw clamp terminals, >= 1 x 0.22 mm² without cable end IEC 60947-1
- [Ui] Rated Insulation Voltage
- 600 V 3)IEC 60947-1
- [Ie] Rated Operational Current
- 3 A 240 V, AC-15, A600 IEC 60947-5-1 || 6 A 120 V, AC-15, A600 IEC 60947-5-1 || 0.1 A 600 V, DC-13, Q600 IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q600 IEC 60947-5-1 || 0.55 A 125 V, DC-13, Q600 IEC 60947-5-1 || 1.2 A 600 V, AC-15, A600 IEC 60947-5-1
- Mechanical Durability
- 300000 cycles
- Electrical Reliability
- λ < 10exp(-6) 5 V, 1 mA IEC 60947-5-4 || λ < 10exp(-8) 17 V, 5 mA IEC 60947-5-4
- Tightening Torque
- 0.8-1.2 N.m IEC 60947-1
- Shape Of Screw Head
- cross Philips no 1 || cross pozidriv No 1 || slotted flat Ø 4 mm || slotted flat Ø 5.5 mm
Specifications
- Control Station Application
- emergency switching off function || emergency stop function
- Product Destination
- for XB5 Ø 22 mm control and signalling units
- Reset
- turn to release
- Range Of Product
- Harmony XALK
- Colour Of Base Of Enclosure
- light grey RAL 7035)
- Control Station Composition
- 1 mushroom head Ø 40 mm push-button, red 1 NC unmarked
- Operators Description
- red unmarked 1 NC
- Product Or Component Type
- complete control station
- Material
- polycarbonate
- Operator Profile
- 1 mushroom head push-button
- Colour Of Cover
- yellow RAL 1021)
- Contact Operation
- slow-break
- Device Short Name
- XALK
CAD Models
traceparts
Herunterladen