Schneider Electric
ZB5AW045
1 / 1
Beschreibung
Aktiv Reif
This light block allows fast and easy replacement and configuration of your signaling units. It is easily installed and replaced on compatible illuminated push button or selector switch units . It is assembled via clips and connected with simple screw-clamp connections. It enables visual distinction of signaling units via illumination by BA9s base Integral LED. It protects operators from unexpected contact with live circuits thanks to its IP20 protection index.- Country of Origin
- FR
- Part Number
- ZB5AW045
- Tariff Code
- 85365080
- EAN
- 3389110909616
- UNSPSC
- 39122216
Zahlungsmethoden:
- Bestes Angebot von:
- Vertrauenswürdiger Automa.Net Lieferant
- Verfügbarkeit:
- 1 Stk.Auf LagerAktualisiert am: 08-11-2024
- Garantie:
- 12 Monate
- Geschätzte Lieferung:
- Auf Anfrage
- Zustand:
- Neuer Überschuss
Neuer Überschuss - Ein neuer, unbenutzter, unbeschädigter Artikel ohne Herstellergarantie. Der Artikel kann ohne Originalverpackung oder in Ersatzverpackung geliefert werden. Wenn vorhanden, könnte die Verpackung geöffnet worden sein.
Sicherer Zahlungsprozess
Rückgabe- und Erstattungsrichtlinien
Versandrichtlinien
Garantiebedingungen
Environment
- Product Certifications
- GL || UL Listed || LROS (Lloyds register of shipping) || DNV || CSA || BV
- Ambient Air Temperature For Operation
- -40-70 °C
- Standards
- UL 508 || IEC 60947-5-1 || CSA C22.2 No 14 || IEC 60947-1 || IEC 60947-5-4 || JIS C8201-5-1 || JIS C8201-1
- Shock Resistance
- 30 gn 18 ms) half sine wave acceleration IEC 60068-2-27 || 50 gn 11 ms) half sine wave acceleration IEC 60068-2-27
- Vibration Resistance
- 5 gn 2-500 Hz)IEC 60068-2-6
- Ambient Air Temperature For Storage
- -40-70 °C
- Electrical Shock Protection Class
- class II IEC 60536
- Protective Treatment
- TH
Contractual warranty
- Warranty
- 18 months
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP1710010EN
- Sustainable Offer Status
- Green Premium product
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation
- X
- Circularity Profile
- ENVEOLI1710010EN
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
Complementary
- Contacts Usage
- standard
- Terminals Description Iso N°1
- (11-12)NC || (13-14)NO
- Short-Circuit Protection
- 10 A cartridge fuse gG IEC 60947-5-1
- Operating Force
- 2 N NC changing electrical state || 2.3 N NO changing electrical state
- Operating Travel
- 1.5 mm NC changing electrical state) || 2.6 mm NO changing electrical state) || 4.3 mm total travel)
- Contacts Material
- silver alloy (Ag/Ni)
- Positive Opening
- with IEC 60947-5-1 appendix K
- [Ith] Conventional Free Air Thermal Current
- 10 A IEC 60947-5-1
- Net Weight
- 0.119 kg
- [Uimp] Rated Impulse Withstand Voltage
- 6 kV IEC 60947-1
- Cad Overall Height
- 42 mm
- Device Presentation
- basic sub-assemblies
- Electrical Durability
- 1000000 cycles, AC-15, 2 A 230 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, AC-15, 3 A 120 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, AC-15, 4 A 24 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, DC-13, 0.2 A 110 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C || 1000000 cycles, DC-13, 0.5 A 24 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C
- [Ui] Rated Insulation Voltage
- 600 V 3)IEC 60947-1
- Signalling Type
- steady
- Operating Torque
- 0.05 N.m NO changing electrical state
- [Ie] Rated Operational Current
- 3 A 240 V, AC-15, A600 IEC 60947-5-1 || 6 A 120 V, AC-15, A600 IEC 60947-5-1 || 0.1 A 600 V, DC-13, Q600 IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q600 IEC 60947-5-1 || 0.55 A 125 V, DC-13, Q600 IEC 60947-5-1 || 1.2 A 600 V, AC-15, A600 IEC 60947-5-1
- Mechanical Durability
- 5000000 cycles
- Electrical Reliability
- λ < 10exp(-6) 5 V 1 mA in clean environment IEC 60947-5-4 || λ < 10exp(-8) 17 V 5 mA in clean environment IEC 60947-5-4
- Tightening Torque
- 0.8-1.2 N.m IEC 60947-1
- Cad Overall Width
- 30 mm
- Cad Overall Depth
- 79 mm
- Shape Of Screw Head
- cross Philips no 1 || cross pozidriv No 1 || slotted flat Ø 4 mm || slotted flat Ø 5.5 mm
- [Us] Rated Supply Voltage
- 220...240 V AC 50/60 Hz
Specifications
- Range Of Product
- Harmony XB5
- Light Source
- incandescent
- Light Block Supply
- via integral transformer 1.2 VA 6 V
- Product Or Component Type
- complete body/contact assembly and light block
- Fixing Collar Material
- plastic
- Head Type
- standard
- Connections - Terminals
- screw clamp terminals, <= 2 x 1.5 mm² with cable end IEC 60947-1 || screw clamp terminals, >= 1 x 0.22 mm² without cable end IEC 60947-1
- Contacts Type And Composition
- 1 NO + 1 NC
- Sale Per Indivisible Quantity
- 1
- Contact Operation
- slow-break
- Device Short Name
- ZB5
- Bulb Base
- BA 9s
CAD Models
traceparts
HerunterladenAndere Kategorien
AktuatorenBlöckeKabel, Rohre & SchläucheKompressorenKontrolleKupplungen & FittingsZylinder & KolbenElektronikFilterHVACIndustrie-PCs & HMIsBeleuchtungLineartechnikMotorenStromversorgungLeistungsübertragungPumpen & VentileErneuerbare energieRobotikDichtungen, Ringe & VerbinderSensoren und MessgeräteWerkzeuge und ZubehörCNCSonstiges