Siemens
6SL3210-1KE31-7AF1
SINAMICS G120C PN 90.0KW FILA
- Erhalten Sie bis zu 90 Tage Zahlungsziele von 500+ Lieferanten
- Wiederverkaufsrabatte bis zu 40%!
€6,233.75
1
Zahlungsmöglichkeiten:
Insgesamt 24 Parts In-Stock von 25 Distributors
Produktbedingungen:
Angebot mit Herstellervorlaufzeit
Lieferung:Auf Anfrage
Bester Preis:
€5,265.61
Beschreibung
AktivRoHS-konform
SINAMICS G120C RATED POWER 90.0KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI. 2DO. 1AI. 1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFINET-PN PROTECTION: IP20/ UL OPEN TYPE SIZE: FSF 708x 305x 357(HXWXD) EXTERNAL 24VAdditional Information
- Part Number
- 6SL3210-1KE31-7AF1
- UPC
- 804766375569
- Tariff Code
- 8504409540
- Country of Origin
- DE
- ETIM
- Group Code : EG000017
- Group Description : Low-voltage Industrial Components
- Class Description : Frequency converter =< 1 kV
- Class Code : EC001857
- Version : 7
Specifications
- Country of Origin
- DE
- Depth
- 357 mm
- Width
- 305 mm
- Height
- 708 mm
- Mains voltage
- 380 V
- With PC connection
- true
- Max. output voltage
- 480 V
- Number of phases input
- 3
- Number of phases output
- 3
- Number of digital inputs
- 6
- Max. output frequency
- 550 Hz
- Number of analogue inputs
- 1
- Number of digital outputs
- 2
- Number of analogue outputs
- 1
- Number of HW-interfaces USB
- 1
- Type of converter
- U converter
- Degree of protection (IP)
- IP20
- Nominal output current I2N
- 164 A
- Number of HW-interfaces other
- 6
- Number of interfaces PROFINET
- 2
- Number of HW-interfaces RS-232
- 1
- Number of HW-interfaces RS-422
- 0
- Number of HW-interfaces RS-485
- 0
- Number of HW-interfaces parallel
- 0
- Integrated breaking resistance
- true
- Number of HW-interfaces serial TTY
- 1
- Supporting protocol for PROFIsafe
- true
- Supporting protocol for EtherNet/IP
- true
- Supporting protocol for PROFINET IO
- true
- Application in industrial area permitted
- true
- Number of HW-interfaces industrial Ethernet
- 2
- Relative symmetric net frequency tolerance
- 5 %
- Relative symmetric net voltage tolerance
- -20 %
- Supporting protocol for other bus systems
- true
- Max. output at linear load at rated output voltage
- 75 kW
- Max. output at quadratic load at rated output voltage
- 90 kW
- Application in domestic- and commercial area permitted
- true
Andere Kategorien
AktuatorenBlöckeKabel, Rohre & SchläucheKompressorenKontrolleKupplungen & FittingsZylinder & KolbenElektronikFilterHVACIndustrie-PCs & HMIsBeleuchtungLineartechnikMotorenStromversorgungLeistungsübertragungPumpen & VentileErneuerbare energieRobotikDichtungen, Ringe & VerbinderSensoren und MessgeräteWerkzeuge und ZubehörCNCSonstiges