Specifications for the TS100 PRO

Maximum Length
8,000 feet (2,438 meters) on certain cable types, 4,000 feet (1,220 meters) on most cable types, and 500 feet (152 meters) on cables with high loss. The tester shows -Err if the cable is too long to be correctly measured.
Representative Maximum Cable Length
8,000 feet (2,438 meters): CAT-3 Twisted Pair || 1,500 feet (457 meters): RG-174/U Coax || 8,000 feet (2,438 meters): CAT-5 Twisted Pair || 3,000 feet (900 meters): RG-6/U TV Coax || 6,000 feet (1,830 meters): 12/2 AC Wire
Minimum Length
No minimum length (can read a bridge tap at 0 feet/meters). Minimum non-zero reading is 2 feet or 1 meter.
Length Accuracy
±2 feet (±0. 6 m) for cables less than 10 feet (3 m) || ±5 feet (±2 m) for cables longer than 10 feet (3 m) and shorter than 200 feet (60 m) || +/-3%+/-5 feet (±2 m) for cables longer than 200 feet (60 m)
Distance to Bridge Tap
0 feet to 3,200 feet (975 meters)
Minimum Length of Bridge Tap
10% of the distance to the bridge tap. Dependent on the cable characteristics.
Measurement Rate
Maximum of 4 complete measurements per second, decreasing to 2 seconds per measurement based on cable size and uniformity.
VOP
Adjustable from 20 to 99, saved in flash memory.
Test Technology
Time Domain Reflectometry (TDR) with 100 Ω drive impedance, 6v maximum pulse height.
Cable Type
Virtually all two or more conductor cables.
Power
4 AA alkaline batteries.
Reverse Battery Protection
No damage to the tester will occur if the batteries are installed backwards.
Battery Life
35 hours (typical)
Low Battery Indication
LED display alternates between LO and bAtt when the battery voltage falls below 4. 5v.
Maximum Output Voltage
4 voltage peak
Maximum Isolation Voltage
250 volts RMS
Voltage Measurements
Accuracy: AC: +/-1%+/-2 volts (45 Hz to 65 Hz); DC: +/-1%+/-2 volts DC || Range: 0 volts AC to 115 volts AC; 0 volts DC to ±150 volts DC
High Voltage Detection
AC voltage detected to 115 volts; DC voltage detected to ±150 volts. || AC voltage ≥90 volts or DC voltage ≥100 volts causes high voltage warnings to show on the display
SmartTone® (5-tones) Range
7,000 feet (2,134 meters)
Toner Range
52,800 feet (16,093 meters)
Tone Injection
Approximately 1 kHz at an amplitude of 80% of battery voltage. Variable frequency and cadence. Tone characteristics change as cable condition changes to “normal-open” from any other condition.
Impedance Range
35 Ω to 330 Ω with auto-compensation within this range. Cables with impedances outside this range will not be properly tested and may produce erratic or incorrect readings.
Temperature Range
Storage: 32°F to 131°F (0°C to 55°C) || Operating: 32°F to 104°F (0°C to 40°C)
Humidity
Storage: 0% to 100% relative humidity || Operating: 20% to 80% relative humidity
Operating Humidity
50% maximum at 104°F (40°C ) || 80% maximum at 86°F (30°C )
Operating Altitude
9,843 ft max (3,000 m max)
Weight
1 lb (454 grams)
Dimensions
7. 4 in x 2. 7 in x 1. 4 in (18. 8 cm x 6. 9 cm x 3. 6 cm)
Safety
EMC: IEC/EN61326-1:2006 || IEC 61010-1:2010; N10140
Certifications and Compliance
Conforms to relevant European Union directives || IEC/EN61010-1 CAN/CSA-C22. 2 No. 1010. 1-92 + CSA-C22. 2 No. 1010. 1B-97, UL/ANSI 3111-1 || Conforms to relevant Australian standards