Capacitance

Accuracy
1% ±4 digits
Resolution
1 μ F (≤ 1000 μF)
Resolution
0.1 μF (≤ 100 μF)
Range
1000 μF

DC Voltage

Range
1000 V
Accuracy
1% ±5 digits
Resolution
0.1 V (≤600.0 V)
Resolution
1 V (≤1000 V)

mV dc

Range
500.0 mV
Accuracy
1% ±5 digits
Resolution
0.1 mV

Mechanical Specifications

Size (L x W x H)
249 x 85 x 45 mm
Operating humidity - non-condensing (< 10°C)
≤45% RH (at 40 °C to 50 °C)
Operating altitude
3000 m
Weight
395 g
Jaw opening
34 mm
Flexible current probe cable length (head to electronics connector)
1.8 m
Safety
IEC 61010-1, Pollution Degree 2
Storage altitude
12,000 m
Operating humidity - non-condensing (< 10°C)
≤75% RH (at 30 °C to 40 °C)
Storage temperature
-40 °C to +60 °C
Safety
IEC 61010-2-033:CAT III 1000 V / CAT IV 600 V
Radio Frequency Certification FCC ID
T68-FBLE IC:6627A-FBLE
Safety
IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V
Flexible current probe diameter
7.5 mm
Batteries
2 AA, NEDA 15A, IEC LR6
Operating temperature
-10 °C to +50 °C
Operating humidity - non-condensing (< 10°C)
≤90% RH (at 10 °C to 30 °C)
Maximum voltage between any terminal and earth ground
1000 V
IP rating
IEC 60529: IP30, non-operating

AC Voltage

Accuracy
1.5% ±5 digits (20 Hz to 500 Hz)
Resolution
1 V (≤1000 V)
Range
1000 V
Resolution
0.1 V (≤600.0 V)

Electromagnetic Compatibility (EMC)

USA (FCC)
47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
International
IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2
Korea (KCC)
Class A Equipment (Industrial Broadcasting & Communication Equipment)
International
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purpose. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.
International
CISPR 11: Group 1, Class A
Temperature coefficients
Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C
Korea (KCC)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
International
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.

AC Current via Flexible Current Probe

Range
2500 A
Resolution
1 A (≤ 2500 A)
Accuracy
3% ±5 digits (5 – 500 Hz)
Resolution
0.1 A (≤ 600 A)
Crest Factor (50/60Hz)
1.42 at 2500 A
Crest Factor (50/60Hz)
Add 2% for C.F. > 2
Crest Factor (50/60Hz)
2.5 at 1400 A

General Specifications

Crest Factor (50 Hz/60 Hz)
Add 2% for C.F. >2
Resolution
0.1 A
Range
600.0 A
Crest Factor (50 Hz/60 Hz)
2.5 @ 600 A
Accuracy
2% ±5 digits (10 Hz to 100 Hz)
Accuracy
2.5% ±5 digits (100-500 Hz)

Resistance

Accuracy
1% ±5 digits
Resolution
0.1 Ω (≤600 Ω)
Range
6000 Ω
Resolution
1 Ω (≤6000 Ω)

DC Current

Accuracy
2% ±5 digits
Resolution
0.1 A
Range
600.0 A