Frequency via Jaw

Range
5.0 Hz to 500.0 Hz
Accuracy
0.5% ±5 digits
Trigger level
5 Hz to 10 Hz, ≥10 A
Resolution
0.1 Hz
Trigger level
10 Hz to 100 Hz, ≥5 A
Trigger level
100 Hz to 500 Hz, ≥10 A

Capacitance

Resolution
1 μ F (≤ 1000 μF)
Range
1000 μF
Resolution
0.1 μF (≤ 100 μF)
Accuracy
1% ±4 digits

DC Voltage

Resolution
1 V (≤1000 V)
Range
1000 V
Resolution
0.1 V (≤600.0 V)
Accuracy
1% ±5 digits

Frequency via Flexible Current Probe

Range
5.0 Hz to 500.0 Hz
Resolution
0.1 Hz
Trigger level
5 Hz to 20 Hz, ≥25 A
Trigger level
100 Hz to 500 Hz, ≥25 A
Accuracy
0.5% ±5 digits
Trigger level
20 Hz to 100 Hz, ≥20 A

mV dc

Range
500.0 mV
Resolution
0.1 mV
Accuracy
1% ±5 digits

Mechanical Specifications

Safety
IEC 61010-1, Pollution Degree 2
Operating altitude
3000 m
Batteries
2 AA, NEDA 15A, IEC LR6
IP rating
IEC 60529: IP30, non-operating
Safety
IEC 61010-2-033:CAT III 1000 V / CAT IV 600 V
Storage altitude
12,000 m
Flexible current probe cable length (head to electronics connector)
1.8 m
Operating humidity - non-condensing (< 10°C)
≤90% RH (at 10 °C to 30 °C)
Safety
IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V
Weight
395 g
Operating humidity - non-condensing (< 10°C)
≤75% RH (at 30 °C to 40 °C)
Size (L x W x H)
249 x 85 x 45 mm
Jaw opening
34 mm
Maximum voltage between any terminal and earth ground
1000 V
Storage temperature
-40 °C to +60 °C
Operating humidity - non-condensing (< 10°C)
≤45% RH (at 40 °C to 50 °C)
Radio Frequency Certification FCC ID
T68-FBLE IC:6627A-FBLE
Operating temperature
-10 °C to +50 °C
Flexible current probe diameter
7.5 mm

AC Voltage

Resolution
1 V (≤1000 V)
Range
1000 V
Accuracy
1.5% ±5 digits (20 Hz to 500 Hz)
Resolution
0.1 V (≤600.0 V)

Electromagnetic Compatibility (EMC)

International
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Korea (KCC)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC)
47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Korea (KCC)
Class A Equipment (Industrial Broadcasting & Communication Equipment)
International
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purpose. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.
Temperature coefficients
Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C
International
IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2
International
CISPR 11: Group 1, Class A

AC Current via Flexible Current Probe

Range
2500 A
Resolution
1 A (≤ 2500 A)
Accuracy
3% ±5 digits (5 – 500 Hz)
Crest Factor (50/60Hz)
Add 2% for C.F. > 2
Crest Factor (50/60Hz)
2.5 at 1400 A
Crest Factor (50/60Hz)
3.0 at 1100 A
Crest Factor (50/60Hz)
1.42 at 2500 A
Resolution
0.1 A (≤ 600 A)

General Specifications

Accuracy
2% ±5 digits (10 Hz to 100 Hz)
Crest Factor (50 Hz/60 Hz)
Add 2% for C.F. >2
Accuracy
2.5% ±5 digits (100-500 Hz)
Range
999.9 A
Crest Factor (50 Hz/60 Hz)
3 @ 500 A
Crest Factor (50 Hz/60 Hz)
2.5 @ 600 A
Resolution
0.1 A

Resistance

Resolution
1 Ω (≤6000 Ω)
Range
60 kΩ
Resolution
0.1 Ω (≤600 Ω)
Accuracy
1% ±5 digits
Resolution
10 Ω (≤60 kΩ)

DC Current

Accuracy
2% ±5 digits
Resolution
0.1 A
Range
600.0 A