Fluke

9142-D-156

The 9142 Series Field Metrology Wells extend high performance to the industrial process environment by maximizing portability, speed, and functionality with little compromise to metrology performance.
9142-D-156
9142-D-156
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

P Specifications

Built-in mA readout accuracy
0.02% of reading + 2 mV
Built-in reference thermometer readout accuracy (4-Wire Reference Probe)1
±0.010°C at -25°C ±0.015°C at 0°C±0.020°C at 50°C±0.025°C at 150°C±0.030°C at 200°C±0.040°C at 350°C±0.050°C at 420°C ±0.070°C at 660°C
RTD measurement capability
4-wire RTD (2-,3-wire RTD w/ Jumpers only)
MA connection
2 terminal input
Reference measurement capability
4-wire
Built-in electronics temperature coefficient (0°C to 13°C, 33°C to 50°C)
±0.005% of range per °C
Reference probe connection
6-pin Din with Infocon Technology
Reference characterizations
ITS-90, CVD, IEC-751, Resistance
TC connection
Small connectors
RTD characterizations
PT-100 (385),(JIS),(3926), NI-120, Resistance
Built-in electronics temperature coefficient (0°C to 13°C, 33°C to 50°C)
1. The temperature range may be limited by the reference probe connected to the readout. The Built-In Reference Thermometer Readout Accuracy does not include the sensor probe accuracy. It does not include the probe uncertainty or probe characterization errors. 2. Measurement accuracy specifications apply within the operating range and assume 4-wires for PRTs. With 3-wire RTDs add 0.05 ohms to the measurement accuracy plus the maximum possible difference between the resistances of the lead wires.
RTD connection
4 terminal input
Reference resistance accuracy2
0 ohms to 42 ohms: ±0.0025 ohms 42 ohms to 400 ohms: ±60 ppm of reading
RTD resistance accuracy2
0 ohms to 25 ohms: ±0.002 ohms 25 ohms to 400 ohms: ±80 ppm of reading
Internal cold junction compensation accuracy
±0.35°C (ambient of 13°C to 33°C)
MA range
Cal 4-22 mA, Spec 4-24 mA
Loop power function
24 V DC loop power
Reference resistance range
0 ohms to 400 ohms
Built-in TC thermometer readout accuracy
Type J: ±0.7°C at 660°C Type K: ±0.8°C at 660°C Type T: ±0.8°C at 400°C Type E: ±0.7°C at 660°C Type R: ±1.4°C at 660°C Type S: ±1.5°C at 660°C Type M: ±1.4°C at 660°C Type L: ±0.7°C at 660°C Type U: ±0.75°C at 600°C Type N: ±0.9°C at 660°C Type C: ±1.1°C at 660°C
TC millivolt range
–10 mV to 75 mV
Voltage accuracy
0.025% of reading + 0.01 mV
Built-in RTD thermometer readout accuracy
NI-120: ±0.015°C at 0°C PT-100 (385): ±0.02°C at 0°C PT-100 (3926): ±0.02°C at 0°C PT-100 (JIS): ±0.02°C at 0°C
RTD resistance range
0 ohms to 400 ohms

Base Unit Specifications

Computer interface
RS-232 and 9930 Interface-it control software included
Resolution
0.01°
Hysteresis
0.025
Power requirements
100 V to 115 V (±10%) 50/60 Hz, 635 W 230 V (±10%) 50/60 Hz, 575 W
Axial uniformity at 40 mm (1.6 in)
±0.05°C full range
Stability
±0.01°C full range
Environmental conditions (for all specifications except temperature range)
13°C to 33°C
Weight
8.16 kg (18 lb)
Immersion (well) Depth
150 mm (5.9 in)
Cooling time
15 min: 23°C to –25°C 25 min: 150°C to –23°C
Operating conditions
0°C to 50°C, 0% to 90% RH (non-condensing)
Loading effect (with a 6.35 mm reference probe and three 6.35 mm probes)
±0.006°C full range
Insert OD
30 mm (1.18 in)
Display
LCD, °C or °F user-selectable
Radial uniformity
±0.01°C full range
Size (H x W x D)
290 x 185 x 295 mm (11.4 x 7.3 x 11.6 in)
Temperature range at 23°C
–25°C to 150°C (–13°F to 302°F)
Heating time
16 min: 23°C to 140°C 23 min: 23°C to 150°C 25 min: –25°C to 150°C
Display accuracy
±0.2°C full range