Fluke

9143-D-156

The 9143 Series Field Metrology Wells extend high performance to the industrial process environment by maximizing portability, speed, and functionality with little compromise to metrology performance.
9143-D-156
9143-D-156
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

P specifications

RTD characterizations
PT-100 (385),(JIS),(3926), NI-120, Resistance
MA connection
2 terminal input
Built-in TC thermometer readout accuracy
Type J: ±0.7°C at 660°C Type K: ±0.8°C at 660°C Type T: ±0.8°C at 400°C Type E: ±0.7°C at 660°C Type R: ±1.4°C at 660°C Type S: ±1.5°C at 660°C Type M: ±1.4°C at 660°C Type L: ±0.7°C at 660°C Type U: ±0.75°C at 600°C Type N: ±0.9°C at 660°C Type C: ±1.1°C at 660°C
Built-in electronics temperature coefficient (0°C to 13°C, 33°C to 50°C)
±0.005% of range per °C
Built-in RTD thermometer readout accuracy
NI-120: ±0.015°C at 0°C PT-100 (385): ±0.02°C at 0°C PT-100 (3926): ±0.02°C at 0°C PT-100 (JIS): ±0.02°C at 0°C
RTD resistance accuracy‡
0 ohms to 25 ohms: ±0.002 ohms 25 ohms to 400 ohms: ±80 ppm of reading
TC millivolt range
–10 mV to 75 mV
Reference measurement capability
4-wire
Built-in reference thermometer readout accuracy (4-Wire reference probe)1
±0.010°C at -25°C ±0.015°C at 0°C ±0.020°C at 50°C ±0.025°C at 150°C ±0.030°C at 200°C ±0.040°C at 350°C ±0.050°C at 420°C ±0.070°C at 660°C
Reference probe connection
6-pin Din with Infocon Technology
MA range
Cal 4-22 mA, Spec 4-24 mA
Voltage accuracy
0.025% of reading + 0.01 mV
Reference resistance range
0 ohms to 400 ohms
RTD connection
4 terminal input
Loop power function
24 V DC loop power
Reference resistance accuracy2
0 ohms to 42 ohms: ±0.0025 ohms 42 ohms to 400 ohms: ±60 ppm of reading
Reference characterizations
ITS-90, CVD, IEC-751, Resistance
RTD measurement capability
4-wire RTD (2-,3-wire RTD w\ Jumpers only)
Built-in mA readout accuracy
0.02% of reading + 2 mV
Built-in electronics temperature coefficient (0°C to 13°C, 33°C to 50°C)
1. The temperature range may be limited by the reference probe connected to the readout. The Built-In Reference Thermometer Readout Accuracy does not include the sensor probe accuracy. It does not include the probe uncertainty or probe characterization errors. 2. Measurement accuracy specifications apply within the operating range and assume 4-wires for PRTs. With 3-wire RTDs add 0.05 ohms to the measurement accuracy plus the maximum possible difference between the resistances of the lead wires.
TC connection
Small connectors
Internal cold junction compensation accuracy
±0.35°C (ambient of 13°C to 33°C)
RTD resistance range
0 ohms to 400 ohms

Base Unit Specifications

Resolution
0.01°
Computer interface
RS-232 and 9930 Interface-it control software included
Display accuracy
±0.2°C Full Range
Stability
±0.02°C at 33°C ±0.02°C at 200°C±0.03°C at 350°C
Radial uniformity
±0.01°C at 33°C ±0.015°C at 200°C±0.02°C at 350°C
Hysteresis
0.03
Insert OD
25.3 mm (1.00 in)
Weight
7.3 kg (16 lb)
Heating time
5 min: 33°C to 350°C
Loading effect (with a 6.35 mm reference probe and three 6.35 mm probes)
±0.015°C Full Range
Environmental conditions (for all specifications except temperature range)
13°C to 33°C
Power requirements
100 V to 115 V (±10%), 50/60 Hz, 1400 W 230 V (±10%), 50/60 Hz, 1800 W
Temperature range at 23°C
33°C to 350°C (91°F to 662°F)
Size (H x W x D)
290 x 185 x 295 mm (11.4 x 7.3 x 11.6 in)
Cooling time
32 min: 350°C to 33°C 14 min: 350°C to 100°C
Axial uniformity at 40 mm (1.6 in)
±0.04°C at 33°C ±0.1°C at 200°C±0.2°C at 350°C
Display
LCD, °C or °F user-selectable
Immersion (well) depth
150 mm (5.9 in)
Operating conditions
0°C to 50°C, 0% to 90% RH (non-condensing)