Potrzebujesz więcej informacji?
EUCHNER MGB-L2-ARA-AF9A1-M-114690
EUCHNER MGB-L2-ARA-AF9A1-M-114690 Locking Module
Opis produktu
The EUCHNER MGB-L2-ARA-AF9A1-M-114690 Locking Module is designed for robust guard locking applications, providing reliable safety and monitoring features. This module features guard locking by solenoid force and includes an emergency stop function compliant with ISO 13850. It can be connected in series with other AR devices, such as CES-AR and CET-AR, making it highly versatile for complex safety systems.
The module is equipped with one illuminated indicator for clear status visibility and offers a high degree of protection with IP65 rating. The housing is made from fiber glass reinforced plastic, nickel-plated die-cast zinc, and stainless steel, ensuring durability in demanding environments. The locking force of 2000 N guarantees secure guard locking, and the device operates on the open-circuit current principle.
Electrical connection values are optimized for reliability, with a rated insulation voltage of 30 V and a rated impulse voltage of 1.5 kV. The module supports a wide range of connection cross-sections and is designed for both rigid and flexible cables. Safety outputs and monitoring outputs are p-switching and short circuit-proof, ensuring consistent performance.
This locking module adheres to stringent safety standards, including EN 60947-5-3, and offers performance levels PL e and SIL 4 for both guard position and guard lock monitoring. The emergency stop function is designed for high reliability with a B10D value of 0.13x106 and a mission time of 20 years.
- Termin płatności do 90 dni od 500+ dostawców.
- Rabaty na odsprzedaż do 40%!
Specyfikacje
- Marka
- EUCHNER
- Connection cross section (rigid/flexible) with cable end sleeve according to DIN 46 228/1
- 0.25 ... 1.5 mm²
- Connection cross section (rigid/flexible) with cable end sleeve with collar according to DIN 46 228/1
- 0.25 ... 0.75 mm²
- Connection cross section (rigid/flexible)
- 0.13 ... 1.5 mm²
- Rated insulation voltage Ui
- 30 V
- Rated impulse voltage Uimp
- 1.5 kV
- Discrepancy time between FO1A and FO1B
- max. 10 ms
Uzyskaj dostęp do naszej platformy, aby znaleźć więcej ofert
Zarejestruj się teraz, aby poznać 36 milionów ofert od zweryfikowanych dostawców z całego świata.
- Porównaj oferty na całym świecie
- Bezpośredni kontakt z dostawcą
- Zapytania ofertowe, wyceny i zamówienia
- Wyszukiwanie BOM
Dokumenty
Karta katalogowa
Karta katalogowa dla EUCHNER MGB-L2-ARA-AF9A1-M-114690, w tym specyfikacje i funkcje.
Modele CAD
Model 3D CAD i rysunki techniczne, gotowe do Twojego oprogramowania projektowego.
Wgląd w rynek

Uzyskaj analizy w czasie rzeczywistym i dane rynkowe, aby zoptymalizować decyzje zakupowe dotyczące tego komponentu i podobnych produktów.
- Dane o dostępności zapasów w czasie rzeczywistym od 700 dystrybutorów MRO w Europie i USA
- Analiza cen według stanu (nowe, używane, odnowione) z medianą cen rynkowych
- Monitorowanie dostępności krytycznych komponentów w celu zapobiegania przestojom produkcji
- Wgląd w optymalizację zapasów w oparciu o trendy podaży rynkowej