Potrzebujesz więcej informacji?

Zadzwoń do nas pod numer:+48 17 778 34 19

Honeywell HVFDSB3A0015G220/U

VFD with Bypass and Disconnect, SmartVFD BYPASS, 208Vac, 1.5 HP, Graphical, NEMA 12 Enclosure, Two Contactor Bypass

1 / 3
Honeywell HVFDSB3A0015G220/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 208Vac, 1.5 HP, Graphical, NEMA 12 Enclosure, Two Contactor Bypass — Przemienniki częstotliwości (Falowniki)
Zdjęcie katalogowe producenta
Honeywell HVFDSB3A0015G220/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 208Vac, 1.5 HP, Graphical, NEMA 12 Enclosure, Two Contactor Bypass — Przemienniki częstotliwości (Falowniki)
Zdjęcie katalogowe producenta
Honeywell HVFDSB3A0015G220/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 208Vac, 1.5 HP, Graphical, NEMA 12 Enclosure, Two Contactor Bypass — Przemienniki częstotliwości (Falowniki)
Zdjęcie katalogowe producenta
Honeywell HVFDSB3A0015G220/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 208Vac, 1.5 HP, Graphical, NEMA 12 Enclosure, Two Contactor Bypass — Przemienniki częstotliwości (Falowniki)
Honeywell HVFDSB3A0015G220/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 208Vac, 1.5 HP, Graphical, NEMA 12 Enclosure, Two Contactor Bypass — Przemienniki częstotliwości (Falowniki)
Honeywell HVFDSB3A0015G220/U VFD with Bypass and Disconnect, SmartVFD BYPASS, 208Vac, 1.5 HP, Graphical, NEMA 12 Enclosure, Two Contactor Bypass — Przemienniki częstotliwości (Falowniki)

Opis produktu

The VFD with Bypass and Disconnect, identified as SmartVFD BYPASS, operates at an input voltage of 208V AC and is equipped with a 1.5 HP motor rating. This device effectively modulates the speed of fans and pumps within HVAC systems, contributing to substantial energy conservation.

Integration with building automation systems (BAS) or use of its internal PID control capabilities allows for optimized performance. The device includes an intuitive graphical interface, facilitating straightforward commissioning alongside startup wizards and PC programming features.

With an overall width of 12 inches (305 mm), height of 37.5 inches (953 mm), and depth of 11 inches (279 mm), the VFD is housed in a NEMA 12 enclosure. The unit weighs 18.2 pounds (40 kg) and is capable of operating efficiently across a range of environmental conditions, with a maximum operating temperature of 104 °F (40 °C) and minimum operating temperature of 14 °F (-10 °C).

Notable specifications include a continuous output current rating of 6.6 A and a control transformer. The device supports various analog inputs and outputs, including options for 0-10Vdc and 0(4)-20mA signals. The VFD also features a maximum acceleration and deceleration time of 3000 seconds, accommodating a variety of application needs.

Regulatory approvals include CE and cUL, ensuring compliance with established standards. This model is specifically designed for variable torque applications, making it suitable for a range of HVAC operations.

Potrzebujesz więcej informacji?

Zadzwoń do nas pod numer:+48 17 778 34 19
  • Termin płatności do 90 dni od 500+ dostawców.
  • Rabaty na odsprzedaż do 40%!
Wyślij zapytanie o cenę
Metody płatności:
Poproś o wycenę, a prześlemy Ci informacje o dostępności i cenie.

Specyfikacje

Type of RFI Filter
EMC Filter
Relay Rated Load
Max load: 250Vac/2A- 250Vdc/0.4A
Regulatory Approvals
CE ; EN 61800-5-1 ; cUL
Reference Output Voltage
10 Vdc- max load 10 mA
Pilot Lights
No
Peak Current
IS- 2s/20s

Dokumenty

Karta katalogowa

Karta katalogowa dla Honeywell HVFDSB3A0015G220/U, w tym specyfikacje i funkcje.

Pobierz arkusz danych
TraceParts

Modele CAD

Model 3D CAD i rysunki techniczne, gotowe do Twojego oprogramowania projektowego.

Pobierz model CAD
Pulpit analityczny AutomaINSIGHTS dla HVFDSB3A0015G220/U

Wgląd w rynek: HVFDSB3A0015G220/U

Uzyskaj analizy w czasie rzeczywistym i dane rynkowe dotyczące HVFDSB3A0015G220/U i innych produktów z kategorii Przemienniki częstotliwości (Falowniki), aby zoptymalizować decyzje zakupowe.

  • Dane o dostępności zapasów w czasie rzeczywistym od 700 dystrybutorów MRO w Europie i USA
  • Analiza cen według stanu (nowe, używane, odnowione) z medianą cen rynkowych
  • Monitorowanie dostępności krytycznych komponentów w celu zapobiegania przestojom produkcji

Powiązane kategorie