The AS-Interface diagnosis and analysis tool, designated as eAS-i Tester, facilitates local diagnostics for AS-i networks, enabling the reading and writing of slave data and parameters. This tool displays all slaves present on the bus, ensuring comprehensive evaluation and reporting capabilities.

Operating within an ambient temperature range of 0 to 55 °C and a storage temperature of -25 to 70 °C, the device is designed to withstand diverse environmental conditions. It features a compact rectangular housing with dimensions of 138 x 91 x 29 mm and weighs 346 grams, making it suitable for various operational setups.

Additionally, the eAS-i Tester includes an undervoltage monitoring feature and complies with multiple EMC standards, such as EN 50081-2 and EN 61000-6-2, with a mean time to failure (MTTF) rating of 280 years. The product is supplied with a D-Sub data cable and software on CD, providing all necessary tools for effective diagnostics and analysis.

Wyślij zapytanie
Metody płatności:

Szczegóły oferty

Najlepsza oferta od:
Zaufany dostawca — Niemcy, członek od 2024
Dostępność:
1 szt.
Na zamówienie
Zaktualizowano: 04-09-2026
Stan produktu:
Nowy Fabrycznie Zapakowany
Nowy Fabrycznie Zapakowany - Nowy, nieużywany, nieotwarty, nieuszkodzony przedmiot w oryginalnym opakowaniu zapieczętowanym przez producenta.
Sprzedawca jest odpowiedzialny za wysyłkę produktu i wystawienie faktury

Specyfikacje

Marka
IFM
Application - Application
Local diagnosis of the AS-i network; creation of test reports for AS-i networks; diagnosis and analysis tool for AS-i
Electrical data - Undervoltage monitoring
yes
Operating conditions - Ambient temperature [°C]
0...55
Operating conditions - Storage temperature [°C]
-25...70
Tests / approvals - EMC | item 1
EN 50081-2
Tests / approvals - EMC | item 2
EN 61000-6-2

Dostępne Oferty

(2)
AC1145 IFM, Sterowanie i HMI

IFM

Dostępność:
1 szt.
W magazynie
Zaktualizowano: 06-09-2026
Oferta od:
Zaufany dostawca — Polska, członek od 2023, 50–99 pracowników
Gwarancja:
24 miesiące

Uzyskaj dostęp do naszej platformy, aby znaleźć więcej ofert

Zarejestruj się teraz, aby poznać 36 milionów ofert od zweryfikowanych dostawców z całego świata.

  • Porównaj oferty na całym świecie
  • Bezpośredni kontakt z dostawcą
  • Zapytania ofertowe, wyceny i zamówienia
  • Wyszukiwanie BOM
Zarejestruj sięDostępny jest bezpłatny 14-dniowy okres próbny

Dokumenty

Karta katalogowa

Karta katalogowa dla IFM AC1145, w tym specyfikacje i funkcje.

Pobierz arkusz danych
TracePartsTraceParts

Modele CAD

Model 3D CAD i rysunki techniczne, gotowe do Twojego oprogramowania projektowego.

Pobierz model CAD

Powiązane produkty

AC1146 IFM
AC1146
IFM
Diagnostic module for AS-i networks designed to monitor message quality and communication status.
AC1150 IFM
AC1150
IFM
This module connects sensors and actuators via cable entry and features cage clamp connections for devices.
SA3010 IFM
SA3010
IFM
Flow monitor; PNP/NPN; switching signal; analogue (configurable); Measuring range 0...10 l/min; Medium temperature 0...80 °C; Pressure rating 30 bar; Connector
AC016S IFM
AC016S
IFM
Facilitates simple mounting and wiring with AS-i flat cable connection through module lower parts.
AC007S IFM
AC007S
IFM
Facilitates the connection of electro-sensitive protective equipment (ESPE) and integrates safety-related components within AS-i systems. Features safe signal detection via dual OSSD inputs.
AC003S IFM
AC003S
IFM
Designed for the safe monitoring of protective systems, capable of overseeing up to 31 safe AS-i slaves.
AC004S IFM
AC004S
IFM
This device is designed for the safe monitoring of protective systems, capable of overseeing up to 31 safe AS-i slaves.
AC006S IFM
AC006S
IFM
Module designed for AS-i flat cable connection, featuring robust M12 connectors and visible LEDs for operation and error indication.
01D100 IFM
01D100
IFM
Niezawodny optyczny pomiar odległości z dużymi zasięgami do 10 m, z dwoma wyjściami przełączającymi i skalowalnym zakresem pomiarowym.
AC001S IFM
AC001S
IFM
Designed for the safe monitoring of protective systems, this device supports applications such as door monitoring, light grids, E-STOP, and two-hand control.
AC0022 IFM
AC0022
IFM
Automation set designed for pneumatic valve actuators, facilitating quick setup and reliable position feedback.
AC0021 IFM
AC0021
IFM
Automation set designed for pneumatic valve actuators, facilitating quick setup and reliable position monitoring.

Wgląd w rynek

AutomaINSIGHTS pulpit analityczny

Uzyskaj analizy w czasie rzeczywistym i dane rynkowe, aby zoptymalizować decyzje zakupowe dotyczące tego komponentu i podobnych produktów.

  • Dane o dostępności zapasów w czasie rzeczywistym od 700 dystrybutorów MRO w Europie i USA
  • Analiza cen według stanu (nowe, używane, odnowione) z medianą cen rynkowych
  • Monitorowanie dostępności krytycznych komponentów w celu zapobiegania przestojom produkcji
  • Wgląd w optymalizację zapasów w oparciu o trendy podaży rynkowej
Rozpocznij