Mersen
MPDB67002
MPDB UL1953 AL INT 1000V 310A 2-pole 1 350-#6 in-1 350-#6 out Box/Box...
- Country of Origin
- MX
- Part Number
- MPDB67002
- Termin płatności do 90 dni od 500+ dostawców.
- Rabaty na odsprzedaż do 40%!
Wyślij zapytanie o cenę
1
Metody płatności:
Additional Information
- Part Number
- MPDB67002
- UPC
- 782001450861
- Country of Origin
- MX
Specifications
- Adder Poles
- All sizes have optional adder poles for increased flexibility and ease-of-use. Adder poles can be stacked to form multi-pole units in the field without the use of tools. Adder poles allow for customization of primary and secondary wire combinations. End barriers are also available for sale, catalog numbers can be found in the catalog number selection tables for each size block.
- Wire Connectors
- Standard aluminum and copper wire connectors are available. Aluminum connectors accept both AL or CU wire while copper connectors accept CU wire only. Connectors are all 1-piece tin-plated. Many part numbers are rated to accept DLO-type fine-strand wire, allowing users to connect flexible conductors.
- Insulators
- Insulators are virtually unbreakable, made of glass-filled polycarbonate. “See-through,” hinged safety covers are optional and provide a greater degree of safety and shock resistance where required. Hinged covers can be installed without tools.
- Spacings
- 1 inch through air and 2 inches over surface between uninsulated live parts of opposite polarity meets requirements for feeder and branch circuit applications of UL508A.
- Safety Covers
- Polycarbonate safety covers provide dead-front protection. One cover is needed for each pole. Each cover has a test probe hole in the center for circuit checking. Covers are optional accessories and catalog numbers can be found in the catalog selection tables for each size block.
- Max Operating Temp
- 80 °C
- Max Storage Temp
- 80 °C
- Min Storage Temp
- -25 °C
- Rated Voltage Ac Ul
- 1000 V
- Rated Voltage Dc Ul
- 1000 V
- Short Circuit Rating Standalone
- 10 kA
- Short Circuit Rating Class Cc
- 30 kA
- Short Circuit Rating Class G
- 60 kA
- Short Circuit Rating Class J
- 400 kA
- Short Circuit Rating Class L
- 400 kA
- Short Circuit Rating Class Rk1
- 200 kA
- Short Circuit Rating Class Rk5
- 100 kA
- Short Circuit Rating Class T
- 400 kA
- Ampere Rating Al
- 250 A
- Ampere Rating Cu
- 310 A
- Hole Diameter Primary
- 0.75 in
- Hole Diameter Secondary
- 0.75 in
- Country Of Origin
- MX
- Product Line
- MPDB Series UL 1953 Open-Style Power Distribution Blocks
- Wire Insulation Rating
- 60/75C
- Wire Type
- Solid/Stranded CU
- Body Insulating Material
- GFPC
- Installation Mounting
- Direct Screw Mount
- Number Of Poles
- 2-pole
- Flammability Rating
- 94 V-0
- Connector Material
- Tin-plated Aluminum
- Connector Type Primary
- Box
- Connector Type Secondary
- Box
- Hex Screw Size And Type Primary
- 11/16-16 x .88
- Hex Screw Size And Type Secondary
- 11/16-16 x .88
- Number Of Openings Per Pole Primary
- 1
- Number Of Openings Per Pole Secondary
- 1
- Torque Rating Primary
- 350-#6 275
- Torque Rating Secondary
- 350-#6 275
- Wire Range Primary
- 350-#6
- Wire Range Secondary
- 350-#6
Dokumenty
Data Sheet
PobierzInne kategorie
SiłownikiBlokiKable, rury i wężeSprężarkiSterowanieŁączniki i osprzętCylindry i tłokiElektronikaFiltryHVACKomputery przemysłowe i interfejsy HMIOświetlenieTechnika liniowaSilnikiZasilaniePrzeniesienie napęduPompy i zaworyEnergia odnawialnaRobotykaUszczelki, pierścienie i złączaCzujniki i urządzenia pomiaroweNarzędzia i akcesoriaCNCInne