Regulated Power Supply, 100 to 240V AC, 12V, 2.1A, single phase, Modular
ABLM1A12021
  • Termin płatności do 90 dni od 500+ dostawców.
  • Rabaty na odsprzedaż do 40%!
Zarejestruj się
€65.78
1
Metody płatności:
Łącznie 123 części w magazynie od 21 dostawców
Oferta z czasem realizacji przez producenta
Wysyłka:1 - 2 Dni robocze
Najlepsza cena:
€36.43

Additional Information

Part Number
ABLM1A12021
UNSPSC
39121004
Tariff Code
8504409510
Country of Origin
TH

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP2004005EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Circularity Profile
ENVEOLI2004005EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Standards
IEC 62368-1 || EN/IEC 61010-1 || EN 61010-2-201 || EN/IEC 61204-3 || IEC 61000-6-1 || IEC 61000-6-2 || IEC 61000-6-3 || IEC 61000-6-4 || IEC 61000-3-2 || EN 61000-3-3 || UL 62368-1 || UL 61010-1 || UL 61010-2-201 || CSA C22.2 No 62368-1 || CSA C22.2 No 61010-1 || CSA C22.2 No 61010-2-201 || EN/IEC 62368-1
Ambient Air Temperature For Operation
-25-55 °C without current derating mounting position A < 6561.68 ft (2000 m) || 55-70 °C with current derating of 2.67 % per °C mounting position A < 6561.68 ft (2000 m)
Product Certifications
CE || cUL Listed || cUL Recognized || RCM || CB Scheme || EAC || KC || NEC class 2
Pollution Degree
2
Electromagnetic Compatibility
immunity to electrostatic discharge - test level: 8 kV (contact discharge) conforming to IEC 61000-4-2 || immunity to electrostatic discharge - test level: 15 kV (air discharge) conforming to IEC 61000-4-2 || electromagnetic field immunity test - test level: 15 V/m (80 MHz...2 GHz) conforming to IEC 61000-4-3 || electromagnetic field immunity test - test level: 5 V/m (2...2.7 GHz) conforming to IEC 61000-4-3 || electromagnetic field immunity test - test level: 5 V/m (2.7...6 GHz) conforming to IEC 61000-4-3 || immunity to fast transients - test level: 4 kV (on input-output) conforming to IEC 61000-4-4 || surge immunity test - test level: 4 kV (between power supply and earth) conforming to IEC 61000-4-5 || surge immunity test - test level: 3 kV (between phases) conforming to IEC 61000-4-5 || immunity to conducted disturbances - test level: 15 V (0.15...80 MHz) conforming to IEC 61000-4-6 || immunity to magnetic fields - test level: 30 A/m (50...60 Hz) conforming to IEC 61000-4-8 || immunity to voltage dips - test level: 100 % (1 cycle) conforming to IEC 61000-4-11 || immunity to voltage dips - test level: 60 % (10 cycles) conforming to IEC 61000-4-11 || immunity to voltage dips - test level: 30 % (25 cycles) conforming to IEC 61000-4-11 || disturbing field emission conforming to EN 55016-2-3 || limits for harmonic current emissions conforming to IEC 61000-3-2 || conforming to EN 55016-1-2 || conforming to EN 55016-2-1
Shock Resistance
150 m/s² 11 ms
Vibration Resistance
3 mm 2-9 Hz)IEC 60721-3-3 || 10 m/s² 9-200 Hz)IEC 60721-3-3
Ip Degree Of Protection
IP20
Operating Altitude
< 6561.68 ft (2000 m) overvoltage category III || 2000 m...5000 m overvoltage category II
Electrical Shock Protection Class
class II without PE connection
Electromagnetic Emission
conducted emissions IEC 61000-6-3 || radiated emissions IEC 61000-6-4

Complementary

Output Coupling
serial
Height
91 mm
Residual Ripple
< 100 mV
Status Led
1 LED (Green) output voltage
Holding Time
> 20 ms 115 V AC || > 60 ms 230 V AC
Efficiency At Full Load
90...264 V AC
Earthing System
TN || TT || IT
Connections - Terminals
screw connection 0.5...1.5 mm², AWG 20...AWG 16) without wire end ferrule input/output || screw connection 0.5...1 mm², AWG 20...AWG 18) with wire end ferrule input/output
Dielectric Strength
3000 V AC input/output
Network Frequency Limits
50-60 Hz
Current Consumption
< 0.8 A 115 V AC || < 0.6 A 230 V AC
Supply
SELV IEC 60950-1 || SELV IEC 60204-1 || SELV IEC 60364-4-41
Net Weight
0.170 kg
Maximum Leakage Current
0.25 mA 240 V AC
Input Protection Type
integrated fuse (not interchangeable) 3.15 A || external protection (recommended) 20 A Curve B || external protection (recommended) 20 A Curve C || external protection (recommended) 4 A Curve B || external protection (recommended) 4 A Curve C
Output Protection Type
against overload and short-circuits automatic reset || against over temperature manual reset || against overvoltage manual reset
Service Life
10 year(s)
Meantime Between Failure [Mtbf]
2500000 h at 25 °C, full load || 1000000 h at 55 °C, 80 % load
Power Dissipation In W
4.6 W
Output Voltage Limits
12...15 V
Mounting Support
top hat type TH35-15 rail IEC 60715 || top hat type TH35-7.5 rail IEC 60715 || double-profile DIN rail || panel mounting
Load Capacitance
3000 µF
Response Time
< 2 s
Line And Load Regulation
< 0.5 % network in line || < 1 % network 0 to 100 % load
Width
36 mm
Overvoltage Category
II
Inrush Current
25 A 115 V || 50 A 230 V
Efficiency
85 % 115 V AC || 85 % 230 V AC
Depth
55.6 mm
Power Factor
0.48 at 115 V AC || 0.38 at 230 V AC

Specifications

Range Of Product
Modicon Power Supply
Output Voltage
12 V DC
Product Or Component Type
power supply
Power Supply Type
regulated switch mode
Input Voltage
100...240 V AC single phase || 100...240 V AC phase to phase
Power Supply Output Current
2.1 A
Kw Rating
25 W
Enclosure Material
Plastic

Dokumenty