Schneider Electric
ATV930D45N4
1 / 6
Opis
Końcówka Serii
This Altivar Process ATV900 variable speed drive can feed 3-phase synchronous and asynchronous power motors. It is suitable for motors with power rating up to 45kW/60hp for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 37kW/50hp for applications requiring significant overload (up to 150%). It works at a rated supply voltage from 380V to 480V AC. This variable speed / frequency drive (VSD / VFD) is specifically designed for industrial processes. In the following market segments, oil and gas, mining, minerals and metals, food and beverage water and wastewater. It offers high motor performance on any motor and total control of any kind of coupling in master/slave applications. Network services help ensure operation continuity even in case of connection breakdown. Web server and data logging help reduce downtime through fast troubleshooting and preventive maintenance. Its advanced connectivity, including EtherNet/IP and Modbus TCP, allows deep integration into automation architectures. It is designed to be mounted in vertical position (+/- 10 °) on a wall.- Country of Origin
- IN
- Part Number
- ATV930D45N4
- Tariff Code
- 85044095
- EAN
- 3606480883385
- UNSPSC
- 39122001
€2,249.10
net€2,499.00
Darmowa wysyłka!1
Metody płatności:
- Najlepsza oferta od:
- Zaufany dostawca Automa.Net
- Dostępność:
- 7 szt.W magazynieZaktualizowano: 19-11-2024
- Gwarancja:
- 24 miesiące
- Szacowany czas dostawy:
- 21-22 listopada do Wielka Brytania
- Stan produktu:
- Fabrycznie Nowe, Zapieczętowane
Fabrycznie Nowe, Zapieczętowane - Nowy, nieużywany, nieotwarty, nieuszkodzony przedmiot w oryginalnym opakowaniu zapieczętowanym przez producenta.
Informacje o wysyłce
Bezpieczny proces płatności
Zasady zwrotów i reklamacji
Zasady wysyłki
Gwarancja
Complementary
- Discrete Input Logic
- positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V || positive logic (source) DI7, DI8), < 0.6 V, > 2.5 V || positive logic (source) STOA, STOB), < 5 V, > 11 V
- Power Dissipation In W
- natural convection 121 W 380 V 4 kHz || forced convection 943 W 380 V 4 kHz
- Analogue Output Type
- software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
- Discrete Output Type
- logic output DQ+ 0-1 kHz <= 30 V DC 100 mA || programmable as pulse output DQ+ 0-30 kHz <= 30 V DC 20 mA || logic output DQ- 0-1 kHz <= 30 V DC 100 mA
- Maximum Switching Current
- relay output R1 resistive, cos phi = 1 3 A 250 V AC || relay output R1 resistive, cos phi = 1 3 A 30 V DC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R2, R3 resistive, cos phi = 1 5 A 250 V AC || relay output R2, R3 resistive, cos phi = 1 5 A 30 V DC || relay output R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC
- 4 Quadrant Operation Possible
- true
- Exchange Mode
- half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
- Local Signalling
- local diagnostic 3 LED mono/dual colour) || embedded communication status 5 LED dual colour) || communication module status 2 LED dual colour) || presence of voltage 1 LED red)
- Data Format
- 8 bits, configurable odd, even or no parity Modbus serial
- Relative Symmetric Network Frequency Tolerance
- 5 %
- Net Weight
- 28.7 kg
- Type Of Polarization
- no impedance
- Relay Output Type
- configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 1000000 cycles || configurable relay logic R3 sequence relay NO 1000000 cycles
- Analogue Input Number
- 3
- Motor Slip Compensation
- automatic whatever the load || adjustable || not available in permanent magnet motor law || can be suppressed
- Discrete Output Number
- 2
- Transmission Rate
- 10/100 Mbit/s Ethernet IP/Modbus TCP || 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial
- Method Of Access
- slave Modbus TCP
- Number Of Addresses
- 1-247
- Discrete Input Number
- 10
- Linearity Error
- AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AQ1, AQ2 +/- 0.2 % analog output
- Number Of Addresses
- 1-247 Modbus serial
- With Safety Function Safe Stop 1 (Ss1)
- true
- Width
- 226 mm
- Transmission Rate
- 10, 100 Mbits || 4.8 kbps || 9600 bit/s || 19200 bit/s
- Depth
- 274 mm
- Analogue Input Type
- AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
- Sampling Duration
- 2 ms +/- 0.5 ms DI1...DI8) - discrete input || 5 ms +/- 1 ms DI7, DI8) - pulse input || 1 ms +/- 1 ms AI1, AI2, AI3) - analog input || 5 ms +/- 1 ms AQ1, AQ2) - analog output
- Electrical Connection
- control screw terminal 0.5...1.5 mm² AWG 20...AWG 16 || line side screw terminal 35...50 mm² AWG 2...AWG 1 || motor screw terminal 50 mm² AWG 1 || DC bus screw terminal 35...50 mm² AWG 3...AWG 1
- With Safety Function Safe Brake Management (Sbc/Sbt)
- true
- Height
- 673 mm
- Acceleration And Deceleration Ramps
- linear adjustable separately from 0.01...9999 s
- Maximum Output Voltage
- 480.0 V
- Base Load Current At High Overload
- 74.5 A
- Transmission Frame
- RTU
- Relay Output Number
- 3
- With Safety Function Safe Torque Off (Sto)
- true
- Data Format
- 8 bits, configurable odd, even or no parity
- Base Load Current At Low Overload
- 88.0 A
- Accuracy
- +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
- Input Compatibility
- DI1...DI8 discrete input level 1 PLC IEC 61131-2 || DI7, DI8 pulse input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC IEC 61131-2
- Connector Type
- 2 RJ45 || 1 RJ45
- Analogue Output Number
- 2
- Physical Interface
- Ethernet || 2-wire RS 485
- Minimum Switching Current
- relay output R1, R2, R3 5 mA 24 V DC
- Refresh Time
- relay output R1, R2, R3)5 ms +/- 0.5 ms)
- Isolation
- between power and control terminals
- Brake Chopper Integrated
- true
- Quantity Per Set
- 1
- Type Of Polarization
- no impedance Modbus serial
- Braking To Standstill
- by DC injection
- Discrete Input Type
- DI1...DI8 programmable, 24 V DC <= 30 V)3.5 kOhm || DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V) || STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
- Protection Type
- thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-circuit protection drive || motor phase break drive || overvoltages on the DC bus drive || line supply overvoltage drive || line supply undervoltage drive || line supply phase loss drive || overspeed drive || break on the control circuit drive
- Supply
- external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for digital inputs and STO 24 V DC 21-27 V), <200 mA overload and short-circuit protection
- With Safety Function Safely Limited Speed (Sls)
- true
Specifications
- Prospective Line Isc
- 50 kA
- Network Frequency
- 50-60 Hz
- Product Destination
- synchronous motors || asynchronous motors
- Line Current
- 79.8 A 380 V normal duty) || 67.1 A 380 V heavy duty) || 69.1 A 480 V normal duty) || 59.0 A 480 V heavy duty)
- Phase
- 3 phase
- Asynchronous Motor Control Profile
- constant torque standard || optimized torque mode || variable torque standard
- Variant
- standard version || with braking chopper
- Product Or Component Type
- variable speed drive
- Apparent Power
- 57.4 kVA 480 V normal duty) || 49.1 kVA 480 V heavy duty)
- Ip Degree Of Protection
- IP21
- Switching Frequency
- 2...16 kHz adjustable || 4...16 kHz with derating factor
- Maximum Transient Current
- 105.6 A 60 s normal duty) || 111.8 A 60 s heavy duty)
- Communication Port Protocol
- EtherNet/IP || Modbus serial || Modbus TCP
- Product Specific Application
- process for industrial
- Option Card
- slot A communication module Profibus DP V1 || slot A communication module PROFINET || slot A communication module DeviceNet || slot A communication module EtherCAT || slot A communication module CANopen daisy chain RJ45 || slot A communication module CANopen SUB-D 9 || slot A communication module CANopen screw terminals || slot A/slot B/slot C digital and analog I/O extension module || slot A/slot B/slot C output relay extension module || slot B 5/12 V digital encoder interface module || slot B analog encoder interface module || slot B resolver encoder interface module || communication module Ethernet Powerlink
- Degree Of Protection
- UL type 1
- Maximum Output Frequency
- 599 Hz
- Range Of Product
- Altivar Process ATV900
- Motor Power Kw
- 45.0 kW normal duty || 37.0 kW heavy duty
- [Us] Rated Supply Voltage
- 380...480 V - 15...10 %
- Mounting Mode
- wall mount
- Discrete Input Logic
- 16 preset speeds
- Continuous Output Current
- 88 A 4 kHz normal duty || 74.5 A 4 kHz heavy duty
- Nominal Switching Frequency
- 4 kHz
- Emc Filter
- integrated || with EMC plate option
- Device Application
- Industrial Application
- Synchronous Motor Control Profile
- permanent magnet motor || synchronous reluctance motor
Environment
- Product Certifications
- CSA || UL || TÜV
- Maximum Deflection Under Vibratory Load (During Operation)
- 1.5 mm at 2...13 Hz
- Standards
- UL 508C || IEC 61800-3 || IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
- Insulation Resistance
- > 1 MOhm 500 V DC for 1 minute to earth
- Shock Resistance
- 15 gn 11 ms IEC 60068-2-27
- Environmental Characteristic
- chemical pollution resistance class 3C3 IEC 60721-3-3 || dust pollution resistance class 3S3 IEC 60721-3-3
- Vibration Resistance
- 1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
- Noise Level
- 71.5 dB 86/188/EEC
- Regulation Loop
- adjustable PID regulator
- Permitted Relative Humidity (During Operation)
- class 3K5 according to EN 60721-3
- Operating Altitude
- <= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
- Overvoltage Category
- III
- Environmental Class (During Operation)
- class 3C3 according to IEC 60721-3-3 || class 3S3 according to IEC 60721-3-3
- Maximum Acceleration Under Shock Impact (During Operation)
- 150 m/s² at 11 ms
- Pollution Degree
- 2
- Electromagnetic Compatibility
- electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5 || conducted radio-frequency immunity test level 3 IEC 61000-4-6
- Ambient Air Temperature For Operation
- -15-50 °C without derating) || 50-60 °C with derating factor)
- Volume Of Cooling Air
- 240 m3/h
- Marking
- CE
- Maximum Acceleration Under Vibrational Stress (During Operation)
- 10 m/s² at 13...200 Hz
- Noise Level
- 71.5 dB
- Ambient Air Temperature For Storage
- -40-70 °C
- Relative Humidity
- 5-95 % without condensation IEC 60068-2-3
- Assembly Style
- enclosed
- Operating Position
- vertical +/- 10 degree
- Maximum Thdi
- <48 % from 80...100 % of load IEC 61000-3-12
- Ambient Air Transport Temperature
- -40-70 °C
Offer Sustainability
- Mercury Free
- Yes
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation
- X
- Upgradeability
- Upgraded components available
- Rohs Exemption Information
- Yes
- Environmental Disclosure
- ENVPEP1411001EN
- Sustainable Offer Status
- Green Premium product
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Circularity Profile
- ENVEOLI1411001EN
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
Modele CAD
traceparts
Pobierz