Schneider Electric
CA2KN40E7
1 / 2
Opis
Końcówka Serii
TeSys K control relay, 4 contacts (4NO), 10A/690V, for control of electromagnetic loads AC-15/DC-13. It provides a 48V 50/60Hz AC control circuit, connection by screw clamp terminals. For high operating rates until 180 cycles/min and ambient temperature -25/+50°C, it procures high reliability and durability. Compact (45mm width), for clipping on 35mm DIN rail or fixing by screw. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium product (RoHS/REACh).- Country of Origin
- FR
- Part Number
- CA2KN40E7
- Tariff Code
- 85364190
- EAN
- 3389110500363
- UNSPSC
- 39122331
Metody płatności:
- Najlepsza oferta od:
- Zaufany dostawca Automa.Net
- Dostępność:
- 24 szt.W magazynieZaktualizowano: 20-11-2024
- Gwarancja:
- 12 miesięcy
- Szacowany czas dostawy:
- Na zapytanie
- Stan produktu:
- Fabrycznie Nowe, Zapieczętowane
Fabrycznie Nowe, Zapieczętowane - Nowy, nieużywany, nieotwarty, nieuszkodzony przedmiot w oryginalnym opakowaniu zapieczętowanym przez producenta.
Informacje o wysyłce
Bezpieczny proces płatności
Zasady zwrotów i reklamacji
Zasady wysyłki
Gwarancja
Environment
- Product Certifications
- CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
- Mechanical Robustness
- vibrations contactor open2 Gn, 5...300 Hz IEC 60068-2-6 || vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6 || shocks contactor open10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed15 Gn for 11 ms IEC 60068-2-27
- Ambient Air Temperature For Operation
- -25-50 °C
- Standards
- EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1
- Flame Retardance
- V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
- Ambient Air Temperature For Storage
- -50-80 °C
- Protective Treatment
- TC IEC 60068
- Ip Degree Of Protection
- IP2X
- Operating Altitude
- 6561.68 ft (2000 m) without derating
Contractual warranty
- Warranty
- 18 months
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP1503003EN
- Sustainable Offer Status
- Green Premium product
- Toxic Heavy Metal Free
- Yes
- Reach Regulation
- Free of Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
- Reach Free Of Svhc
- Yes
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Circularity Profile
- ENVEOLI1503003EN
- Eu Rohs Directive
- Compliant
Complementary
- Minimum Switching Current
- 5 mA
- Height
- 58 mm
- Control Circuit Voltage Limits
- drop-out: 0.2...0.75 Uc (at <50 °C) || operational: 0.8...1.15 Uc (at <50 °C)
- Non Overlap Distance
- 0.5 mm
- [Ith] Conventional Free Air Thermal Current
- 10 A (at 50 °C)
- Mounting Support
- rail || plate
- Immunity To Microbreaks
- 2 ms
- Insulation Resistance
- > 10 MOhm
- Irms Rated Making Capacity
- 110 A IEC 60947
- Associated Fuse Rating
- 10 A gG conforming to IEC 60947 || 10 A gG conforming to VDE 0660
- Net Weight
- 0.18 kg
- Inrush Power In Va
- 30-30 VA (at 20 °C)
- Connections - Terminals
- screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible with cable end || screw clamp terminals 2 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-1.5 mm²flexible with cable end || screw clamp terminals 2 0.34-1.5 mm²flexible without cable end
- Minimum Switching Voltage
- 17 V
- Maximum Operating Rate
- 10000 cyc/h
- Tightening Torque
- 1.3 N.m screw clamp terminals flat Ø 6 mm || 1.3 N.m screw clamp terminals Philips No 2 6 mm || 1.3 N.m screw clamp terminals pozidriv No 2
- Mechanical Durability
- 10 Mcycles
- Hold-In Power Consumption In Va
- 4.5-4.5 VA (at 20 °C)
- Operating Time
- 10...20 ms coil de-energisation and NO opening || 10...20 ms coil energisation and NO closing
- Width
- 45 mm
- Depth
- 57 mm
- [Ui] Rated Insulation Voltage
- 690 V IEC 60947 || 750 V VDE 0110 group C || 690 V BS 5424 || 600 V CSA C22.2 No 14
- Heat Dissipation
- 1.3-1.3 W
Specifications
- [Ue] Rated Operational Voltage
- <= 690 V <= 400 Hz
- Control Circuit Type
- AC 50/60 Hz
- [Uc] Control Circuit Voltage
- 48 V AC 50/60 Hz
- Contactor Application
- control circuit
- Product Or Component Type
- control relay
- Product Name
- TeSys CAK
- Range
- TeSys
- Pole Contact Composition
- 4 NO
- Utilisation Category
- DC-13 || AC-15
- Device Short Name
- CA2K
Modele CAD
traceparts
PobierzInne kategorie
SiłownikiBlokiKable, rury i wężeSprężarkiSterowanieŁączniki i osprzętCylindry i tłokiElektronikaFiltryHVACKomputery przemysłowe i interfejsy HMIOświetlenieTechnika liniowaSilnikiZasilaniePrzeniesienie napęduPompy i zaworyEnergia odnawialnaRobotykaUszczelki, pierścienie i złączaCzujniki i urządzenia pomiaroweNarzędzia i akcesoriaCNCInne