Schneider Electric
LC1F780
contactor, TeSys F, 3P(3NO), AC-3, <=440V 780A with coil LX1/LX9 110…500V AC 40/400Hz, LX4 110...440V DC
- Termin płatności do 90 dni od 500+ dostawców.
- Rabaty na odsprzedaż do 40%!
€3,581.00
1
Metody płatności:
Łącznie 5 części w magazynie od 18 dostawców
Stan produktu:
Oferta z czasem realizacji przez producenta
Wysyłka:Na zapytanie
Najlepsza cena:
€2,618.13
Additional Information
- Part Number
- LC1F780
- UNSPSC
- 39121529
- Tariff Code
- 8536490065
- Country of Origin
- CZ
Specifications
- [Ue] Rated Operational Voltage
- <= 1000 V AC 50/60 Hz || <= 460 V DC
- Contactor Application
- resistive load || motor control
- Product Or Component Type
- contactor
- Product Name
- TeSys F
- Range
- TeSys
- Pole Contact Composition
- 3 NO
- [Ie] Rated Operational Current
- 780 A 55 °C) <= 440 V AC AC-3 || 1600 A 40 °C) <= 440 V AC AC-1
- Utilisation Category
- AC-4 || AC-3 || AC-1
- Poles Description
- 3P
- Motor Power Kw
- 450 kW 1000 V AC 50/60 Hz AC-3) || 400 kW 380...400 V AC 50/60 Hz AC-3) || 425 kW 415 V AC 50/60 Hz AC-3) || 425 kW 440 V AC 50/60 Hz AC-3) || 450 kW 500 V AC 50/60 Hz AC-3) || 220 kW 220...240 V AC 50/60 Hz AC-3) || 475 kW 660...690 V AC 50/60 Hz AC-3) || 110 kW 400 V AC 50/60 Hz AC-4)
- Device Short Name
- LC1F
Contractual warranty
- Warranty
- 18 months
Complementary
- Product Certifications
- UL || LROS (Lloyds register of shipping) || RINA || DNV || CCC || BV || CB || ABS || UKCA
- Power Dissipation Per Pole
- 60 W AC-3 || 250 W AC-1
- Average Impedance
- 0.1 mOhm - Ith 1600 A 50 Hz
- Control Circuit Voltage Limits
- operational: 0.85...1.1 Uc AC 40...400 Hz with LX1/LX9 coil || drop-out: 0.2...0.4 Uc AC 40...400 Hz with LX1/LX9 coil || operational: 0.85...1.1 Uc DC with LX4 coil || drop-out: 0.2...0.4 Uc DC with LX4 coil
- [Ith] Conventional Free Air Thermal Current
- 1600 A 40 °C
- Standards
- IEC 60947-1 || IEC 60947-4-1 || EN 60947-1 || JIS C8201-4-1 || EN 60947-4-1
- [Uc] Control Circuit Voltage
- 110...500 V AC 40...400 Hz with LX1/LX9 coil || 48...440 V DC with LX4 coil
- Mounting Support
- plate
- Rated Breaking Capacity
- 6240 A IEC 60947-4-1
- Irms Rated Making Capacity
- 7800 A AC IEC 60947-4-1
- Associated Fuse Rating
- 800 A aM <= 440 V || 1600 A gG <= 440 V
- [Uimp] Rated Impulse Withstand Voltage
- 8 kV
- Connections - Terminals
- power circuit bar 2 100 x 5 mm || power circuit bolted connection || control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible with cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm²solid without cable end || control circuit screw clamp terminals 1 1-4 mm² || control circuit screw clamp terminals 2 1-4 mm²
- Inrush Power In Va
- 1900-2300 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil || 1960-2420 VA (at 20 °C)with LX4 coil
- Maximum Operating Rate
- 600 cyc/h 55 °C
- Operating Time
- 40...80 ms closing with LX1/LX9 coil || 130...230 ms opening with LX1/LX9 coil || 70...80 ms closing with LX4 coil || 100...130 ms opening with LX4 coil
- Tightening Torque
- power circuit 58 N.m || control circuit 1.2 N.m
- Mechanical Durability
- 5 Mcycles
- Compatibility Code
- LC1F
- Hold-In Power Consumption In Va
- 44-55 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil || 42-52 VA (at 20 °C)with LX4 coil
- Overvoltage Category
- III
- [Ui] Rated Insulation Voltage
- 1000 V IEC 60947-4-1 || 1500 V VDE 0110 group C
- [Icw] Rated Short-Time Withstand Current
- 3000 A 40 °C - 3 min || 6250 A 40 °C - 10 s || 5600 A 40 °C - 30 s || 4600 A 40 °C - 1 min || 2200 A 40 °C - 10 min
- Heat Dissipation
- 22-22 W
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP1505009EN
- Sustainable Offer Status
- Green Premium product
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation
- Product out of China RoHS scope. Substance declaration for your information.
- Circularity Profile
- ENVEOLI1505009EN
- Eu Rohs Directive
- Compliant
Environment
- Mechanical Robustness
- vibrations contactor open2.5 Gn, 5...300 Hz || vibrations contactor closed5.5 Gn, 5...300 Hz || shocks contactor open5 Gn for 1/2 sine wave (11 ms) || shocks contactor closed15 Gn for 1/2 sine wave (11 ms)
- Ambient Air Temperature For Operation
- -5-55 °C
- Height
- 434 mm
- Net Weight
- 48 kg
- Ambient Air Temperature For Storage
- -60-80 °C
- Protective Treatment
- TH
- Ip Degree Of Protection
- IP20 front face with shrouds IEC 60529 || IP20 front face with shrouds VDE 0106
- Operating Altitude
- 9842.52 ft (3000 m) without derating
- Width
- 702 mm
- Depth
- 255 mm
- Permissible Ambient Air Temperature Around The Device
- -40-70 °C
Dokumenty
Data Sheet
PobierzModele CAD
traceparts
Pobierz