1 / 1
thumbnail

Opis

Końcówka Serii
TeSys T is a motor management system that provides full motor monitoring, control, and protection when used with short circuit protection and a contactor. It manages most critical processes while reducing downtime and increasing productivity as well as predicts what will happen in the process, as it accurately monitors current, voltage, and power over a wide range. This motor management system is also a flexible system that supports six communication protocols which are Modbus™, CANopen, DeviceNet™, Profibus™, Ethernet/IP, and Modbus/TCP. TeSys T motor management system consist of several components which include the LTMR controller, the expansion module, HMI and software along with several accessories. The LTMR controller is the main component of the system that manages the basic functions. This includes the measurement of the ground current, motor temperature, three phase current of the motor, the controller also includes logic inputs and outputs which is used in fault management. The expansion module is directly connected to the controller and provides additional inputs as well as measure the voltage between the phases which allow the controller the monitor additional functions. TeSys T is highly reliable and has a very long product life thanks to a state-of-the-art component selection, to the all in one design and to the advanced electronic protection. TeSys T can be integrated in many different types of harsh environment such as dusty atmospheres, marine applications, high vibration applications and corrosive atmospheres and is used in Metal/Mining/Mineral, Oil & Gas, Water Wastewater. This is a TeSys T LTMR controller that measure current range of 0.4-8A with a supply voltage of 100-240 Vac and uses Modbus as the communication protocol. This controller measures temperature, phase current, imbalance current, average current and earth-fault current. The dimensions of this device are 61 mm (H) X 91 mm (W) X 122.5 mm (D) and it weighs 0.53 kg.
Country of Origin
CN
Part Number
LTMR08MFM
Tariff Code
85371091
EAN
3389119404631
UNSPSC
39122214
£449.10
net
£499.00
Wysyłka od:
£35.00
1
Metody płatności:
Najlepsza oferta od:
GBZaufany dostawca Automa.Net
Dostępność:
1 szt.
W magazynie
Zaktualizowano: 08-11-2024
Gwarancja:
6 miesięcy
Szacowany czas dostawy:
11-12 listopada do Wielka Brytania
Stan produktu:
Fabrycznie Nowe, Zapieczętowane
Fabrycznie Nowe, Zapieczętowane - Nowy, nieużywany, nieotwarty, nieuszkodzony przedmiot w oryginalnym opakowaniu zapieczętowanym przez producenta.
Łącznie 144 części w magazynie od 20 dostawców
Informacje o wysyłce
Bezpieczny proces płatności
Zasady zwrotu i refundacji
Zasady wysyłki
Gwarancja

Dostępne Oferty (22)

LTMR08MFM product image
Schneider Electric

LTMR08MFM

Stan produktu:
Fabrycznie Nowe, Zapieczętowane
Dostępność:
14 szt.
W magazynie
Zaktualizowano: 09-11-2024
Oferta od:
GBZaufany dostawca Automa.Net
Szacowany czas dostawy:
Na zapytanie
1
£599.96
net
LTMR08MFM product image
Schneider Electric

LTMR08MFM

Stan produktu:
Fabrycznie Nowe, Zapieczętowane
Dostępność:
9 szt.
W magazynie
Zaktualizowano: 09-11-2024
Oferta od:
NLZaufany dostawca Automa.Net
Szacowany czas dostawy:
Na zapytanie
1
€652.18
net
LTMR08MFM product image
Schneider Electric

LTMR08MFM

Stan produktu:
Fabrycznie Nowe, Zapieczętowane
Dostępność:
9 szt.
W magazynie
Zaktualizowano: 09-11-2024
Oferta od:
DEZaufany dostawca Automa.Net
Szacowany czas dostawy:
Na zapytanie
1
€664.00
net
LTMR08MFM product image
Schneider Electric

LTMR08MFM

Stan produktu:
Fabrycznie Nowe, Zapieczętowane
Dostępność:
9 szt.
W magazynie
Zaktualizowano: 09-11-2024
Oferta od:
ITZaufany dostawca Automa.Net
Szacowany czas dostawy:
Na zapytanie
1
€704.06
net
LTMR08MFM product image
Schneider Electric

LTMR08MFM

Stan produktu:
Fabrycznie Nowe, Zapieczętowane
Dostępność:
14 szt.
W magazynie
Zaktualizowano: 09-11-2024
Oferta od:
ESZaufany dostawca Automa.Net
Szacowany czas dostawy:
Na zapytanie
1
€751.02
net
Oferta z czasem realizacji przez producenta
Wysyłka:Na zapytanie
Najlepsza cena:
€247.09

Environment

Product Certifications
ABS || KERI || BV || EAC || CSA || GL || C-tick || ATEX || UL || RMRoS || NOM || CCC || DNV || RINA || LROS (Lloyds register of shipping)
Mechanical Robustness
vibrations mounted on symmetrical rail1 Gn, 5...300 Hz EN/IEC 60068-2-6 || vibrations plate mounted4 Gn, 5...300 Hz EN/IEC 60068-2-6 || shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27
Ambient Air Temperature For Operation
-20-60 °C
Standards
IACS E10 || IEC 60947-4-1 || UL 508 || EN 60947-4-1 || CSA C22.2 No 14
Ambient Air Temperature For Storage
-40-80 °C
Protective Treatment
12 x 24 hour cycles EN/IEC 60068-2-30 || 48 h EN/IEC 60070-2-11 || TH EN/IEC 60068
Operating Altitude
<= 6561.68 ft (2000 m) without derating
Fire Resistance
650 °C EN/IEC 60695-2-12 || 960 °C UL 94
Ip Degree Of Protection
IP20

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP060308EN_V2
Sustainable Offer Status
Green Premium product
Pvc Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile
ENVEOLI100411EN_V2
Eu Rohs Directive
Compliant with Exemptions
Halogen Content Performance
Halogen free plastic parts product

Complementary

Contacts Type And Composition
1 NO + 1 NC fault signal || 3 NO
Height
61 mm
Connection Pitch
5.08 mm
Permissible Power
480 VA AC-15), Ie = 2 A, 500000 cycles output) || 30 W DC-13), Ie = 1.25 A, 500000 cycles output)
Network And Machine Diagnosis Type
event recording || fault recording || waiting time after overload tripping || running hours counter/operating time || phase fault and earth fault trip counters || trip context information || starting current and time || motor control command recording || remaining operating time before overload tripping || trip history information
Pollution Degree
3
Logic Input Number
6
Maximum Operating Rate
1800 cyc/h
Connections - Terminals
control circuit connector 1 0.25-2.5 mm² AWG 24...AWG 14)flexible with cable end || control circuit connector 1 0.2-2.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 1 0.25-2.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 1 0.2-2.5 mm² AWG 24...AWG 14)solid without cable end || control circuit connector 2 0.2-1 mm² AWG 24...AWG 14)flexible with cable end || control circuit connector 2 0.2-1.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 2 0.5-1.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 2 0.2-1 mm² AWG 24...AWG 14)solid without cable end
Input Current
3.1 mA 100 V || 7.5 mA 240 V
Current State 1 Guaranteed
logic input 79...264 V >= 2 mA 25 ms
Net Weight
0.53 kg
[Uimp] Rated Impulse Withstand Voltage
4 kV supply, inputs and outputs EN/IEC 60947-4-1 || 6 kV current or voltage measurement circuit EN/IEC 60947-4-1 || 0.8 kV communication circuit EN/IEC 60947-4-1
Associated Fuse Rating
4 A gG output || 0.5 A gG control circuit
Electromagnetic Compatibility
electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 || communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5 || control circuit: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 || radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3 || fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 || fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 || voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11 || conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 || temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5 || temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 || control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5
Measurement Accuracy
5...15 % earth fault current internal measurement || 1 % voltage 100...830 V) || 3 % power factor || 5 % earth fault current external measurement || +/- 30 min/year internal clock || 0,02 Temperature || 1 % current || 5 % active and reactive power
Current State 0 Guaranteed
logic input 0...40 V <= 15 mA 25 ms
[Ui] Rated Insulation Voltage
690 V EN/IEC 60947-1 || 690 V CSA C22.2 No 14 || 690 V UL 508
Short-Circuit Withstand
100 kA conforming to EN/IEC 60947-4-1
Compatibility Code
LTMR
Protection Type
reverse polarity protection || locked rotor || earth-leakage protection || thermal overload protection || phase failure || overload || thermal protection || power factor variation || load fluctuation || phase unbalance || overload (long time)
Web Services
web server
Width
91 mm
Load Current
5 A 250 V AC logic output || 5 A 30 V DC logic output
Tightening Torque
control circuit 0.5-0.6 N.m flat 3 mm
Overvoltage Category
III
Depth
122.5 mm
Maximum Operating Frequency
2 Hz
Metering Type
average current Iavg || temperature || earth-fault current || imbalance current || phase current I1, I2, I3 RMS

Specifications

Product Or Component Type
motor controller
Product Name
TeSys T
Measurement Current
0.4-8 A
Range
TeSys
Current Consumption
8...62.8 mA
[Us] Rated Supply Voltage
100...240 V AC 50/60 Hz
Communication Port Protocol
Modbus
Bus Type
Modbus 2-wire RS 485 1...247 1.2...19.2 kbit/s, RJ45 2 shielded twisted pairs || Modbus 2-wire RS 485 1...247 1.2...19.2 kbit/s, terminal block 2 shielded twisted pairs
Supply Voltage Limits
93.5-264 V AC
Device Application
equipment monitoring and control
Device Short Name
LTMR

Modele CAD

traceparts
traceparts
Pobierz