Schneider Electric
LV426950
standard auxiliary contact, ComPact NSXm, circuit breaker status OF/SD, 1 changeover contact type
- Termin płatności do 90 dni od 500+ dostawców.
- Rabaty na odsprzedaż do 40%!
€22.33
1
Metody płatności:
Łącznie 553 części w magazynie od 24 dostawców
Stan produktu:
Oferta z czasem realizacji przez producenta
Wysyłka:Na zapytanie
Najlepsza cena:
€7.20
Additional Information
- Part Number
- LV426950
- UNSPSC
- 39121522
- Tariff Code
- 8536507000
- Country of Origin
- CN
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Toxic Heavy Metal Free
- Yes
- Reach Regulation
- Free of Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Reach Free Of Svhc
- Yes
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Eu Rohs Directive
- Compliant
Specifications
- Range Compatibility
- PowerPact PowerPact B || ComPact ComPact NSXm
- Product Or Component Type
- auxiliary contact
- Signal Contacts Composition
- 1 NO/NC
- Device Application
- breaker status monitoring
- Device Short Name
- SD || OF
Complementary
- Fault Type
- overload || short-circuit
- Auxiliary Connection Terminal
- spring
- [Ith] Conventional Free Air Thermal Current
- 5 A
- Wire Stripping Length
- 8 mm for front connection
- Mounting Mode
- clip-on
- Auxiliary Contacts Type
- standard
- [Ie] Rated Operational Current
- AC-12: 5 A at 24 V AC 50/60 Hz || AC-12: 5 A at 48 V AC 50/60 Hz || AC-12: 5 A at 110...127 V AC 50/60 Hz || AC-12: 5 A at 220/240 V AC 50/60 Hz || AC-12: 5 A at 380/440 V AC 50/60 Hz || AC-12: 5 A at 660/690 V AC 50/60 Hz || AC-15: 5 A at 24 V AC 50/60 Hz || AC-15: 5 A at 48 V AC 50/60 Hz || AC-15: 4 A at 110...127 V AC 50/60 Hz || AC-15: 3 A at 220/240 V AC 50/60 Hz || AC-15: 2.5 A at 380/440 V AC 50/60 Hz || AC-15: 0.1 A at 660/690 V AC 50/60 Hz || DC-12: 5 A at 24 V DC 50/60 Hz || DC-12: 2.5 A at 48 V DC 50/60 Hz || DC-12: 0.6 A at 110 V DC 50/60 Hz || DC-12: 0.3 A at 250 V DC || DC-13: 2.5 A at 24 V DC || DC-13: 1.2 A at 48 V DC || DC-13: 0.35 A at 110 V DC || DC-13: 0.05 A at 250 V DC || DC-14: 1 A at 24 V DC || DC-14: 0.2 A at 48 V DC || DC-14: 0.05 A at 110 V DC || DC-14: 0.03 A at 250 V DC
- Local Signalling
- for open/close ON/OFF indication || for relay trip indicator trip indicator
- Minimum Load
- 2 mA 17 V DC