Potrzebujesz więcej informacji?

Zadzwoń do nas pod numer:+48 17 778 34 19

Schneider Electric LX1G3TKUEN

Control module, LX1G, TeSys Giga, standard contactor, 100-250VAC/DC, for LC1G630-800, 3 pole

1 / 1
Schneider Electric LX1G3TKUEN Control module, LX1G, TeSys Giga, standard contactor, 100-250VAC/DC, for LC1G630-800, 3 pole — Akcesoria ogólne
Zdjęcie katalogowe producenta

Opis produktu

Status Cyklu Życia:
It is a 100-250V AC/DC control module for 3 poles TeSys Giga 630-800 contactor (advanced version). Coil designed for less energy consumption and wider voltage band-width, connection by spring terminal. It allows contactor operation with high AC-3 operating rates until 600 cycles/hour and environments until 60°C. Control module has connectors for connecting the coil control A1, A2 circuit, pole status and diagnostic signaling circuits. Local Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It is accessible from the front and maintained with very low down times. Unique QR code provides quick access to complete product data.

Potrzebujesz więcej informacji?

Zadzwoń do nas pod numer:+48 17 778 34 19
Porównaj oferty
Metody płatności:

Szczegóły oferty

Oferta od:
Zaufany dostawca — Rumunia, członek od 2023, 1–4 pracowników 
Dostępność:
Na zamówienieTermin realizacji: 21 dni
Gwarancja:
Nie podano
Stan produktu:
Nowy (nadwyżka magazynowa)
Nowy (nadwyżka magazynowa) - Nowy, nieużywany, nieuszkodzony przedmiot bez gwarancji producenta. Przedmiot może być dostarczony bez oryginalnego opakowania lub w zastępczym opakowaniu. Jeśli dostarczono, pudełko mogło zostać otwarte.
Sprzedawca jest odpowiedzialny za wysyłkę produktu i wystawienie faktury

Specyfikacje

Control Circuit Voltage Limits
operational 0.8...1.1 Uc 60 °C) || drop-out 0...0.45 Uc 60 °C)
Connections - Terminals
control circuit push-in termination 1 0.2-2.5 mm² solid stranded without cable end sleeve AWG 26...AWG 12 || control circuit push-in termination 1 0.25-2.5 mm² flexible with cable end sleeve AWG 24...AWG 14 || control circuit push-in termination 2 0.5-1.0 mm² rigid or stranded with cable end sleeve AWG 20...AWG 18
Coil Technology
built-in bidirectional peak limiting
Control circuit voltage limits
Operational: 0.8...1.1 Uc (at 60 °C) || Drop-out: 0...0.45 Uc (at 60 °C)
Connections - terminals
Control circuit: push-in termination 1 cable(s) 0.2…2.5 mm² solid stranded without cable end sleeve 26 AWG...12 AWG || Control circuit: push-in termination 1 cable(s) 0.25…2.5 mm² flexible with cable end sleeve 24 AWG...14 AWG || Control circuit: push-in termination 2 cable(s) 0.5…1.0 mm² rigid or stranded with cable end sleeve 20 AWG...18 AWG
Ambient Air Temperature For Operation
-25-60 °C

Dostępne oferty

(2)
Stan produktuDostępnośćDostawcaGwarancjaDziałanie
Schneider Electric LX1G3TKUEN
Stan produktu
Nowy (nadwyżka magazynowa)
Dostępność
Na zamówienieTermin realizacji: 21 dni
Dostawca
RumuniaZaufany dostawca — członek od 2023, 1–4 pracowników 
Gwarancja
Nie podano
Schneider Electric LX1G3TKUEN
Stan produktu
Nowy Fabrycznie Zapakowany
Dostępność
Na zamówienieTermin do potwierdzenia
Dostawca
WłochyZaufany dostawca — członek od 2021, 10–19 pracowników 
Gwarancja
12 miesięcy

Oferta z czasem realizacji przez producenta

Bezpośrednio od producenta - z potwierdzonym, przewidywalnym i w pełni transparentnym czasem dostawy.

Dokumenty

Karta katalogowa

Karta katalogowa dla Schneider Electric LX1G3TKUEN, w tym specyfikacje i funkcje.

Pobierz arkusz danych
TraceParts

Modele CAD

Model 3D CAD i rysunki techniczne, gotowe do Twojego oprogramowania projektowego.

Pobierz model CAD

Dane produktu zaktualizowano: 22-08-2026

Pulpit analityczny AutomaINSIGHTS dla LX1G3TKUEN

Wgląd w rynek: LX1G3TKUEN

Uzyskaj analizy w czasie rzeczywistym i dane rynkowe dotyczące LX1G3TKUEN i innych produktów z kategorii Akcesoria ogólne, aby zoptymalizować decyzje zakupowe.

  • Dane o dostępności zapasów w czasie rzeczywistym od 700 dystrybutorów MRO w Europie i USA
  • Analiza cen według stanu (nowe, używane, odnowione) z medianą cen rynkowych
  • Monitorowanie dostępności krytycznych komponentów w celu zapobiegania przestojom produkcji

Powiązane kategorie