The EM3500 series offer a three-phases DIN rail-mounted energy meters fitted for accurate cost allocation and sub-metering. EM35xx models are designed for use with Low Votage Current Transducers 1/3Volt or 1Volt output. Current input from 5A to 32000A, according to the LVCT configuration in the HMI, ANSI C12.20 0.2% accuracy, IEC 62053-22 class 0.2S. The data logging capability protects data in the event of a power failure. Modbus, pulse output, and phase alarms are all provided to suit a wide variety of applications. This model add a bi-directional monitoring feature designed expressly for renewable energy applications. Suitable for a 230V AC network, with a supply voltage range of 90V AC to 300V AC at 50Hz or 60Hz. Compliant with UL508, CSA 22.2 number 14-05 and EN 61010-1. Product dimensions are as follows: width 107 mm, depth 59 mm, height 91 mm.- Country of Origin
- US
- Part Number
- METSEEM3555
- Tariff Code
- 9028300000
- EAN
- 39121108
- UPC
- 785901488514
- UNSPSC
- 39121108
- Termin płatności do 90 dni od 500+ dostawców.
- Rabaty na odsprzedaż do 40%!
Wyślij zapytanie o cenę
1
Metody płatności:
Complementary
- Network Frequency
- 60 Hz || 50 Hz
- Communication Port Support
- screw terminal block RS485
- [Ue] Rated Operational Voltage
- 90...347 V AC 50/60 Hz between phase and neutral UL || 156...600 V AC 50/60 Hz between phases UL || 90...300 V AC 50/60 Hz between phase and neutral CE || 125...300 V DC
- Standards
- CSA C22.2 No 14-05 || UL 508 || IEC 61010-1
- Number Of Outputs
- 1 alarm output || 1 pulse
- Mounting Support
- DIN rail
- Power Consumption In Va
- 5-5 VA 347 V AC between phase and neutral) || 5-5 VA 600 V AC between phases)
- Product Certifications
- CE IEC 61010 || cULus UL 508
- Type Of Measurement
- active and reactive power total || active and reactive power per phase || apparent power total || apparent power per phase || power factor total || power factor per phase || peak demand power || current || voltage || frequency
- Communication Port Protocol
- Modbus RTU 1200…38400 bps - 2-wire
- Communication Service
- total cumulated active energy || total cumulated energy
- Ride-Through Time
- 100 ms 120 V AC
- Display Digits
- 5
- Communication Of Data
- instantaneous and demand values || lifetime energy production
- Tamperproof Of Settings
- protected by access code
- Measurement Current
- 5-32000 A
- Information Displayed
- status and alert || communication with system || input/output status || error || Tx activity || Rx activity || instant power per usage
- Function Available
- external synchronisation to communication || fixed or rolling block
- Mounting Mode
- clip-on || by screws
- Local Signalling
- Red LED threshold reached || Green flashing LED output signal
- Power Consumption In W
- 3 W 300-300 V
- Measurement Accuracy
- power +/- 0.2 % || energy +/- 0.2 %
- Technology Type
- electronic
- Buffer Size
- 16-bit 10
- Poles Description
- 3P + N
- Data Recording
- energy consumption logs || time stamping
- Analogue Input Type
- split core current transducer 0.333 V or 1 V
- Display Type
- Backlit LCD
- Device Application
- partial meter || sub billing
- Accuracy Class
- class 0.2S power IEC 62053-22 || class 0.2S energy IEC 62053-22 || class 0.2S power ANSI C12.20 || class 0.2S energy ANSI C12.20
- Rated Voltage
- 90-347 V
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation
- X
- Eu Rohs Directive
- Compliant with Exemptions
Specifications
- Product Or Component Type
- energy meter
- Product Name
- PowerLogic EM3500
- Range
- PowerLogic
- Device Short Name
- EM3555
- Metering Type
- peak demand power PM, QM, SM || current I1, I2, I3, Iavg || active, reactive, apparent energy (signed, four quadrant) || demand power P, Q, S || voltage U21, U32, U13, V1, V2, V3
Environment
- Ambient Air Temperature For Operation
- -30-70 °C
- Height
- 91 mm
- 9 Mm Pitches
- 12
- Color
- dark grey
- Ambient Air Temperature For Storage
- -40-85 °C
- Relative Humidity
- 0-95 %
- Width
- 107 mm
- Depth
- 59 mm
Dokumenty
Data Sheet
PobierzInne kategorie
SiłownikiBlokiKable, rury i wężeSprężarkiSterowanieŁączniki i osprzętCylindry i tłokiElektronikaFiltryHVACKomputery przemysłowe i interfejsy HMIOświetlenieTechnika liniowaSilnikiZasilaniePrzeniesienie napęduPompy i zaworyEnergia odnawialnaRobotykaUszczelki, pierścienie i złączaCzujniki i urządzenia pomiaroweNarzędzia i akcesoriaCNCInne