Opis
Końcówka Serii
PowerPacT Q-Frame circuit breakers are used for overcurrent protection and switching on 240VAC systems. They are rated for 240VAC operational voltage and provide thermal magnetic trip protection. PowerPacT Q circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. This unit has lugs on both the line and load sides. This PowerPacT Q, 100A, 2 pole, circuit breaker has an interrupting rating of 25kA at 208Y/120VAC and 240VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT Q circuit breakers comply to UL, CSA, and NOM standards and are IEC certified.- Country of Origin
- MX
- Part Number
- QDL22100
- Tariff Code
- 8536200020
- UPC
- 785901522812
- UNSPSC
- 39121601
Metody płatności:
- Najlepsza oferta od:
- Zaufany dostawca Automa.Net
- Dostępność:
- 156 szt.W magazynieZaktualizowano: 09-11-2024
- Szacowany czas dostawy:
- Na zapytanie
- Stan produktu:
- Nowy, Rynek wtórny
Nowy, Rynek wtórny - Nowy, nieużywany, nieuszkodzony przedmiot bez gwarancji producenta. Przedmiot może być dostarczony bez oryginalnego opakowania lub w zastępczym opakowaniu. Jeśli dostarczono, pudełko mogło zostać otwarte.
Bezpieczny proces płatności
Zasady zwrotu i refundacji
Zasady wysyłki
Gwarancja
Environment
- Ambient Air Temperature For Operation
- 40-70 °C
- Standards
- UL || CSA || NEMA || NOM-003-SCFI-2000
- Product Certifications
- UL || CSA || NOM
Contractual warranty
- Warranty
- 18 months
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP1406032EN
- Sustainable Offer Status
- Green Premium product
- Pvc Free
- Yes
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- China Rohs Regulation
- Product out of China RoHS scope. Substance declaration for your information.
- Circularity Profile
- N/A
- Eu Rohs Directive
- Compliant with Exemptions
- Halogen Content Performance
- Halogen free product
Complementary
- Mounting Mode
- unit mount lug)
- Network Frequency
- 50/60 Hz
- Trip Unit Technology
- thermal-magnetic
- Height
- 6.47 in
- [Ue] Rated Operational Voltage
- 240 V AC 50/60 Hz UL
- Tightening Torque
- 28-28 N.m 25-150 mm² (AWG 4...300 kcmil)
- Mounting Support
- lug
- Breaking Capacity Code
- D
- Magnetic Tripping Current
- 2400-2400 A
- Local Signalling
- 1 trip indicator green)
- Electrical Connection
- lugs, load || lugs, line
- [Uimp] Rated Impulse Withstand Voltage
- 8 kV UL
- Magnetic Hold Current
- 1200 A
- Control Type
- operating handle
- Circuit Breaker Application
- HACR rated
- Wire Stripping Length
- 22 mm
- Utilisation Category
- category A
- Line Rated Current
- 100-100 A
- Continuous Current Rating
- 80 %
- Breaking Capacity
- 25 kA 120/208 V AC 50/60 Hz UL || 25 kA 240 V AC 50/60 Hz UL
- Mechanical Durability
- 1000 cycles loaded || 5000 cycles no load
- Poles Description
- 2P
- Line Rated Current
- 100 A
- Width
- 3.00 in
- Depth
- 3.93 in
Specifications
- Product Or Component Type
- circuit breaker
- Product Name
- PowerPact Q
- Range
- PowerPact
- Device Application
- distribution
Dokumenty
Data Sheet
PobierzInne kategorie
SiłownikiBlokiKable, rury i wężeSprężarkiSterowanieŁączniki i osprzętCylindry i tłokiElektronikaFiltryHVACKomputery przemysłowe i interfejsy HMIOświetlenieTechnika liniowaSilnikiZasilaniePrzeniesienie napęduPompy i zaworyEnergia odnawialnaRobotykaUszczelki, pierścienie i złączaCzujniki i urządzenia pomiaroweNarzędzia i akcesoriaCNCInne