Meter mains, Homeline, CSED, ringed socket, 200A, surface mount, maximum 8 spaces, 16 circuits, no bypass
SC816D200C
  • Termin płatności do 90 dni od 500+ dostawców.
  • Rabaty na odsprzedaż do 40%!
Zarejestruj się
Wyślij zapytanie o cenę
1
Metody płatności:
Poproś o wycenę, a prześlemy Ci informacje o dostępności i cenie.

Additional Information

Part Number
SC816D200C
UPC
785901859161
UNSPSC
39121102
Tariff Code
8537109150
Country of Origin
MX

Environment

Product Certifications
UL E-6294

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1407020EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
China Rohs Regulation
Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile
N/A
Eu Rohs Directive
Compliant with Exemptions

Complementary

Height
34.00 in
Tightening Torque
main lugs 250 lb.in, AWG 6...300 kcmil, aluminium/copper || service ground 50 lb.in, AWG 14...AWG 1/0, copper || service ground 50 lb.in, AWG 12...AWG 1/0, aluminium || lugs 250 lb.in, AWG 6...250 kcmil, aluminium/copper || branch lugs 50 lb.in, AWG 3...AWG 1/0, aluminium/copper || branch lugs 45 lb.in, AWG 6...AWG 4, aluminium/copper || branch lugs 40 lb.in, AWG 8, aluminium/copper || branch lugs 35 lb.in, AWG 14...AWG 10, copper || branch lugs 35 lb.in, AWG 12...AWG 10, aluminium || Cover 10 lb.in
Branch Circuit Breaker Rated Current
100 A
Bypass Type
no bypass
Service Feed Location
OH || UG
Bus Rated Current
200.0 A
Electrical Connection
lugs, line side || feed-thru lugs, service ground || feed-thru lugs, load side
Number Of Circuits
16
Number Of Spaces
8
Short-Circuit Current
10 kA
Number Of Tandem Circuit Breakers
8
Hub Type
A || A-L
Meter Socket Type
ringed
Service Disconnect Rated Current
200 A
Line Rated Current
200 A
Awg Gauge
AWG 6...300 kcmil aluminium/copper)line side || AWG 12...AWG 1/0 aluminium/copper)service ground || AWG 6...250 kcmil aluminium/copper)load side
Width
14.95 in
Depth
7.12 in
Network Number Of Phases
1
Device Composition
service disconnect (factory installed)
Device Mounting
surface

Specifications

Range Of Product
Homeline
Product Or Component Type
Meter Mains

Dokumenty

Data Sheet

Pobierz

Powiązane produkty