Electrical data - Serial diagnostic SD

Designation, Serial diagnostic SD
OUT
Operation current
150 mA
Design of control elements
short-circuit proof, p-type
Wiring capacitance
50 nF

Electrical data

No-load supply current I
100 mA
Operating current
600 mA
Required rated short-circuit current
100 A
Note (Electrical data, Fuse rating)
(Circuit breaker)
Switching frequency, approx.
3 Hz

Note

Note (General)
Evaluation requirements: dual-channel safety input, suitable for p-type sensors with NO function. The safety-monitoring module must tolerate internal functional tests of the sensors with cyclic switch-off of the sensor outputs for max. 0.5 ms. Short-circuit recognition by the evaluation is not necessary.

Mechanical data - Dimensions

Length of sensor
35 mm
Width of sensor
27 mm
Height of sensor
108.2 mm

Pin assignment

PIN 1
1A1 Ue: (1)
PIN 2
X1 Safety input 1
PIN 3
A2 GND
PIN 4
Y1 Safety output 1
PIN 5
SD serial diagnostic output
PIN 6
X2 Safety input 2
PIN 7
Y2 Safety output 2
PIN 8
IN serial diagnostic input

Ambient conditions - Insulation values

Rated insulation voltage U
32 VDC
Rated impulse withstand voltage U
0.8 kV
Overvoltage category
III
Degree of pollution
3

Scope of delivery

Scope of delivery
Actuator must be ordered separately.

General data - Features

Serial diagnostics
Yes
Diagnostic output
Yes
Short circuit detection
Yes
Cross-circuit detection
Yes
Safety functions
Yes
Cascadable
Yes
Integral system diagnostics, status
Yes
Number of LEDs
3
Number of semi-conductor outputs with signaling function
1
Number of fail-safe digital outputs
2
Number of series-wiring of sensors
31

General data

Standards
EN IEC 60947-5-3
Working principle
inductive
Housing construction form
Block
Installation conditions (mechanical)
not flush
Sensor topology
Sensor for series wiring
Enclosure material
Glass-fibre, reinforced thermoplastic
Active area
Glass-fibre, reinforced thermoplastic
Gross weight
140 g
Reaction time, maximum
30 ms
Duration of risk, maximum
60 ms

Safety classification

Standards
EN ISO 13849-1 | EN IEC 60947-5-3 | EN IEC 61508
Performance Level, up to
e
Category
4
PFH value
3.60 x 10⁻⁹ /h
Safety Integrity Level (SIL), suitable for applications in
3
Mission time
20 Year(s)

Electrical data - Safety digital outputs

Rated operating current (safety outputs)
250 mA
Output current, (fail-safe output), maximum
0.25 A
Design of control elements
p-type
Voltage drop U
0.5 V
Leakage current I
0.5 mA
Voltage, Utilisation category DC-12
24 VDC
Current, Utilisation category DC-12
0.25 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
0.25 A

Ambient conditions

Degree of protection
IP65 | IP67
Ambient temperature
-25 ... +70 °C
Storage and transport temperature, minimum
-25 °C
Storage and transport temperature, maximum
+85 °C
Resistance to vibrations
10 … 55 Hz, amplitude 1 mm
Restistance to shock
30 g / 11 ms
Protection class
II

Mechanical data - Connection technique

Termination
Connector plug M12, 8-pole
Note (length of the sensor chain)
Cable length and cross-section change the voltage drop dependiing on the output current
Note (series-wiring)
Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD

Electrical data - Diagnostic outputs

Design of control elements
p-type
Voltage drop U
5 V

Mechanical data - Switching distances according EN IEC 60947-5-3

Nominal switching distance S
10 mm | 14 mm
Assured switching distance "ON" S
12 mm | 8 mm
Assured switching distance "OFF" S
13 mm | 17 mm

Mechanical data

Actuating panels
lateral
Active area
lateral
Switching distance actuator
Actuator CST 180-1 / CST 180-2: 10 mm | Actuator CST 180-1 / CST 180-2: 13 mm | Actuator CST 180-1 / CST 180-2: 8 mm | Actuator CST 34-S-1: 12 mm | Actuator CST 34-S-1: 14 mm | Actuator CST 34-S-1: 17 mm | Actuator CST 34-S-2: 12 mm | Actuator CST 34-S-2: 14 mm | Actuator CST 34-S-2: 17 mm | Actuator CST 34-S-3: 12 mm | Actuator CST 34-S-3: 14 mm | Actuator CST 34-S-3: 17 mm
Hysteresis (Switching distance), maximum
1.5 mm
Repeat accuracy R
0.5 mm
Note (Repeat accuracy R)
Axial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 36 mm (e.g. mounting tolerance or due to guard door sagging). Increased misalignment, max. 53 mm, possible when the CST 34-S-2 actuator is used. The axial misalignment (y) is max. ± 10 mm (see figure: Operating principle)

Accessory

Recommendation (actuator)
CST 34-S-2 | CST 34-S-3 | CST 180-1 | CST 180-2 | CST 34-S-1
Recommended safety switchgear
PROTECT PSC1 | SRB-E-301ST | SRB-E-201LC

Approvals - Standards

Certificates
TÜV | cULus | UKCA

Electrical data - Electromagnetic compatibility (EMC)

Interfering radiation
IEC 61000-6-4
EMC rating
IEC 61000-6-2

CAD Models

Trace parts
Trace parts
Download