Schneider Electric GV4PE07S

Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 100kA, thermal magnetic, Everlink terminals

(22 offers)
Image of the product GV4PE07S
A total of  22 Offer On-request from 21 Distributors
TeSys GV motor circuit breaker, 3 poles (3P), 7A/690V, for protection of 3-phase motors 1.5-3kW@400V. It provides thermal magnetic protection and additional motor protection functions, breaking capacity Icu 100kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 2.9-7A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Additional protections have fixed pick-up and include short time delay protection Isd at 13 Ir, phase unbalance and loss protection, ground fault protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).

Suppliers

On Request Parts

These parts are not in the warehouse and will be quoted with manufacturer lead time. Send inquiry for supplier details.
Register to See Company
Country: Estonia
On Request Updated 28/07/2024
  • Quantity: New: 0 pcs.
Register to See Company
Country: Lithuania
On Request Updated 28/07/2024
  • Quantity: New: 0 pcs.
On Request Updated 28/07/2024
  • Quantity: New Sealed: 0 pcs.
Register to See Company
Country: Germany
On Request Updated 28/07/2024
  • Quantity: New Sealed: 0 pcs.
Register to See Company
Country: Czech Republic
On Request Updated 28/07/2024
  • Quantity: New Sealed: 0 pcs.

Additional information

Part Number GV4PE07S
RoHS Status Yes
Lifecycle status 00

Environment

Product Certifications IEC || UL || CSA || CCC || EAC || ATEX || EU-RO MR
Ik Degree Of Protection IK07 IEC 62262
Ambient Air Temperature For Operation -25-70 °C
Standards CSA C22.2 No 60947-4-1 || UL 60947-4-1 || EN/IEC 60947-4-1 || EN/IEC 60947-2
Climatic Withstand IACS E10
Pollution Degree 3
Ambient Air Temperature For Storage -50-85 °C
Ip Degree Of Protection IP40 IEC 60529
Operating Altitude 5000 m
Fire Resistance 960 °C IEC 60695-2-11

Contractual warranty

Warranty 18 months

Offer Sustainability

Rohs Exemption Information Yes
Mercury Free Yes
Environmental Disclosure ENVPEP1704004EN
Sustainable Offer Status Green Premium product
Pvc Free Yes
Reach Regulation Reference contains Substances of Very High Concern above the threshold
Weee The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile ENVEOLI1704004EN
Eu Rohs Directive Compliant with Exemptions
Halogen Content Performance Halogen free plastic parts product

Complementary

Mechanical Robustness vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 || vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 || shocks 15 gn 11 ms IEC 60068-2-27
Line Rated Current 7 A
[Ue] Rated Operational Voltage 690 V AC 50/60 Hz IEC 60947-2
Height 155 mm
Phase Failure Sensitivity yes IEC 60947-4-1
Rated Duty continuous IEC 60947-4-1
Magnetic Tripping Current 119-119 A
[Ith] Conventional Free Air Thermal Current 115 A IEC 60947-4-1
Motor Power Kw 1.5-1.5 kW 400...415 V AC 50/60 Hz || 2.2-2.2 kW 400...415 V AC 50/60 Hz || 2.5-2.5 kW 400...415 V AC 50/60 Hz || 3-3 kW 400...415 V AC 50/60 Hz || 2.2-2.2 kW 500 V AC 50/60 Hz || 2.5-2.5 kW 500 V AC 50/60 Hz || 3-3 kW 500 V AC 50/60 Hz || 4-4 kW 500 V AC 50/60 Hz || 3-3 kW 660...690 V AC 50/60 Hz || 4-4 kW 660...690 V AC 50/60 Hz || 5.5-5.5 kW 660...690 V AC 50/60 Hz || 7.5-7.5 kW 660...690 V AC 50/60 Hz
Maximum Operating Rate 25 cyc/h
Operating Position any position
Connections - Terminals EverLink BTR screw connectors top) 1 1.5-70 mm² - solid || EverLink BTR screw connectors top) 1 1.5-50 mm² - flexible || EverLink BTR screw connectors bottom) 1 2.5-95 mm² - solid || EverLink BTR screw connectors bottom) 1 2.5-70 mm² - flexible
Utilisation Category category A IEC 60947-2 || AC-3 IEC 60947-4-1
Net Weight 1.45 kg
[Uimp] Rated Impulse Withstand Voltage 8 kV IEC 60947-2
Control Type toggle
Power Dissipation Per Pole 4.6 W
Electrical Durability 40000 cycles AC-3 440 V In/2 || 40000 cycles AC-3 440 V In
Breaking Capacity 120 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 || 70 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 30 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 18 kA Icu 525 V AC 50/60 Hz IEC 60947-2 || 100 kA 208Y/120 V AC 50/60 Hz UL 60947 || 100 kA 240 V AC 50/60 Hz UL 60947 || 65 kA 480Y/277 V AC 50/60 Hz UL 60947 || 10 kA Icu 660...690 V AC 50/60 Hz IEC 60947-2 || 25 kA 600Y/347 V AC 50/60 Hz UL 60947
Suitability For Isolation yes IEC 60947-1
[Ui] Rated Insulation Voltage 800 V AC 50/60 Hz IEC 60947-2
Tightening Torque 9 N.m 16-95 mm² || 5 N.m 1.5-10 mm²
Mechanical Durability 40000 cycles
Poles Description 3P
Color Gray RAL 7016)
Width 81 mm
Depth 116 mm

Specifications

Range Of Product TeSys GV4
Product Or Component Type motor circuit breaker
Product Name TeSys GV4 || TeSys Deca
Range TeSys Deca
Device Application motor protection
Device Short Name GV4PE
Trip Unit Technology electronic || thermal-magnetic

Documents

Data Sheet

Download

CAD Models

TraceParts logo

TraceParts