A total of 123 Parts In-Stock from 28 Distributors

Environment

Product Certifications
RCM || CE || EAC || CSA || CCC || UL || GL
Ambient Air Temperature For Operation
-20-60 °C
Standards
UL 508 || IEC 61812-1
Electromagnetic Compatibility
fast transients immunity test - test level: 1 kV level 3 (capacitive connecting clip) conforming to IEC 61000-4-4 || surge immunity test - test level: 1 kV level 3 (differential mode) conforming to IEC 61000-4-5 || surge immunity test - test level: 2 kV level 3 (common mode) conforming to IEC 61000-4-5 || electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2 || electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 (80 MHz...1 GHz) conforming to IEC 61000-4-3 || conducted RF disturbances - test level: 10 V level 3 (0.15...80 MHz) conforming to IEC 61000-4-6 || fast transient bursts - test level: 2 kV level 3 (direct contact) conforming to IEC 61000-4-4 || immunity to microbreaks and voltage drops - test level: 30 % (500 ms) conforming to IEC 61000-4-11 || immunity to microbreaks and voltage drops - test level: 100 % (20 ms) conforming to IEC 61000-4-11
Dielectric Strength
2.5 kV 1 mA/1 minute 50 Hz between relay output and power supply basic insulation IEC 61812-1
Shock Resistance
15 gn not operating 11 ms IEC 60068-2-27 || 5 gn in operation 11 ms IEC 60068-2-27
Vibration Resistance
20 m/s² 10-150 Hz)IEC 60068-2-6
Pollution Degree
3 IEC 60664-1
Directives
2004/108/EC - electromagnetic compatibility || 2006/95/EC - low voltage directive
Ambient Air Temperature For Storage
-40-70 °C
Relative Humidity
95-95 % 25-55 °C
Ip Degree Of Protection
housing IP40 IEC 60529 || terminals IP20 IEC 60529 || front panel IP50 IEC 60529

Complementary

Power Consumption In W
1.5 W 240 V DC
Safety Reliability Data
B10d = 160000 || MTTFd = 171.2 years
Contacts Type And Composition
1 C/O timed or instantaneous contact, cadmium free || 2 C/O timed contact, cadmium free
Setting Accuracy Of Time Delay
+/- 10 % of full scale 25 °C IEC 61812-1
Creepage Distance
4 kV/3 IEC 60664-1
Maximum Delay Response
100 ms
Control Type
rotary knob || diagnostic button || potentiometer external
Insulation Resistance
100 MOhm 500 V DC IEC 60664-1
Immunity To Microbreaks
10 ms
Power Consumption In Va
3-3 VA 240 V AC
Switching Capacity In Va
2000 VA
Minimum Pulse Duration
100 ms with load in parallel || 30 ms
Maximum Switching Current
8 A
Function Available
A- Power on-delay relay-2 C/O || At- Power on-delay relay w/ pause/summation (X1)-2 C/O || Aw- Power on-delay relay w/ retrigger/restart-2 C/O || C- Off-delay relay w/ control signal-2 C/O || Ct- Off-delay relay w/ control signal and pause/summation-2 C/O || D- Symmetrical flashing relay (starting pulse-off)-2 C/O || Dt- Symmetrical flashing relay (starting pulse-off) w/ pause/summation (X1)-2 C/O || Dw- Symmetrical flashing relay (starting pulse-off) w/ retrigger/restart-2 C/O || Di- Symmetrical flashing relay (starting pulse-on)-2 C/O || Dit- Symmetrical flashing relay (starting pulse-on) w/ pause/summation (X1)-2 C/O || Diw- Symmetrical flashing relay (starting pulse-on) w/ retrigger/restart-2 C/O || H- Interval relay-2 C/O || Ht- Interval relay w/ pause/summation (X1)-2 C/O || Hw- Interval relay w/ retrigger/restart-2 C/O || Qg- Star-delta relay (2 CO outputs w/ same common)-2 C/O || Qgt- Star-delta relay (2 CO outputs w/ same common) w/ pause/summation-2 C/O || Qt- Star-delta relay (2 CO outputs w/ split common)-2 C/O || Qtt- Star-delta relay (2 CO outputs w/ split common) w/ pause/summation (X1)-2 C/O || W- Interval relay w/ control signal off-2 C/O || Wt- Interval relay w/ control signal off and pause/summation-2 C/O
Voltage Range
0.85...1.1 Us
Net Weight
0.105 kg
Mounting Position
any position
Voltage Drift
+/- 0.2 %/V
Reset Time
120 ms on de-energisation
Maximum Switching Voltage
250 V AC
Connections - Terminals
screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end || screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end || screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end || screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end
[Us] Rated Supply Voltage
24...240 V AC/DC 50/60 Hz
Temperature Drift
+/- 0.05 %/°C
Time Delay Range
3...30 min || 30...300 min || 0.3...3 s || 3...30 h || 10...100 s || 1...10 s || 0.05...1 s || 30...300 s || 30...300 h || 3...30 s
Minimum Switching Current
10 mA 5 V DC
Overvoltage Category
III IEC 60664-1
Input Voltage
<= 2.4 V
Mounting Support
35 mm DIN rail conforming to IEC 60715
Electrical Durability
100000 cycles, 8 A at 250 V, AC-1 || 100000 cycles, 2 A at 24 V, DC-1
Mechanical Durability
10000000 cycles
Housing Material
self-extinguishing
Status Led
Green LED backlight steady)dial pointer indication || Yellow LED steady)output relay energised || Yellow LED fast flashing)timing in progress and output relay de-energised || Yellow LED slow flashing)timing in progress and output relay energised
[Uimp] Rated Impulse Withstand Voltage
5 kV 1.2-50 µs IEC 60664-1
Width
22.5 mm
Time Delay Type
power on-delay || off-delay || symmetrical flashing || interval || star-delta
Tightening Torque
0.6-1 N.m IEC 60947-1
Supply Frequency
50...60 Hz +/- 5 %
Repeat Accuracy
+/- 0.5 % IEC 61812-1

Specifications

Discrete Output Type
relay
Range Of Product
Harmony Timer Relays
Product Or Component Type
multifunction relay
Nominal Output Current
8 A
Device Short Name
RE22

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1401008EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
China Rohs Regulation
X
Circularity Profile
ENVEOLI1401008EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Documents

Data Sheet

Download

CAD Models

Trace parts
Trace parts
Download

Related products