Schneider Electric
TM4PDPS1
network switch module, Modicon M241, 1 Profibus DP slave
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
$859.50
1
Payment methods:
A total of 55 Parts In-Stock from 20 Distributors
Product Conditions:
Offer with manufacturer lead time
Ships in:On Request
Best price:
€138.64
Additional Information
- Part Number
- TM4PDPS1
- UNSPSC
- 32151705
- Tariff Code
- 8517620090
- Country of Origin
- ID
Complementary
- Electrical Connection
- screw connector terminal for connecting the functional ground || SUB-D 9 1 female connector for connecting Profibus
- Height
- 90 mm
- Integrated Connection Type
- Profibus DP female SUB-D 9
- Transmission Rate
- 1.5 Mbit/s 200-200 m || 500 kbit/s 400-400 m || 187.5 kbit/s 1000-1000 m || 9.6...93.75 kbit/s 1200-1200 m || 3...12 Mbit/s 100-100 m
- Marking
- CE
- Net Weight
- 0.1 kg
- Current Consumption
- 290 mA 5 V DC communication bus
- Communication Port Protocol
- Profibus DP V0 || Profibus DP V1
- Power Dissipation In W
- 1.5 W
- Product Compatibility
- Modicon M241 logic controller || Modicon M251 logic controller
- Mounting Support
- top hat type TH35-15 rail IEC 60715 || top hat type TH35-7.5 rail IEC 60715 || plate or panel with fixing kit
- Local Signalling
- for power supply 1 LED (green/yellow) || for communication 1 LED (green/red)
- Surge Withstand
- 1 kV power lines (DC) common mode IEC 61000-4-5 || 2 kV power lines (AC) common mode IEC 61000-4-5 || 2 kV relay output common mode IEC 61000-4-5 || 1 kV I/O common mode IEC 61000-4-5 || 1 kV shielded cable common mode IEC 61000-4-5 || 0.5 kV power lines (DC) differential mode IEC 61000-4-5 || 1 kV power lines (AC) differential mode IEC 61000-4-5 || 1 kV relay output differential mode IEC 61000-4-5 || 0.5 kV I/O differential mode IEC 61000-4-5
- Range Compatibility
- Modicon M251 || Modicon M241
- Width
- 25 mm
- Depth
- 90 mm
- Insulation
- between bus and internal logic 1000 V DC
Environment
- Product Certifications
- C-tick || cULus
- Resistance To Conducted Disturbances
- 10 V 0.15...80 MHz IEC 61000-4-6 || 3 V 0.1...80 MHz Marine specification (LR, ABS, DNV, GL) || 10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) Marine specification (LR, ABS, DNV, GL)
- Resistance To Electromagnetic Fields
- 10 V/m 80 MHz...1 GHz IEC 61000-4-3 || 3 V/m 1.4 GHz...2 GHz IEC 61000-4-3 || 1 V/m 2...2.7 GHz IEC 61000-4-3
- Standards
- IEC 61131-2 || UL 508 || EIA-485
- Ambient Air Temperature For Operation
- -10-55 °C horizontal installation || -10-50 °C vertical installation
- Storage Altitude
- 0-3000 m
- Pollution Degree
- 2
- Shock Resistance
- 15 gn 11 ms
- Vibration Resistance
- 1 mm 5-13.2 Hz symmetrical rail || 3 gn 8.7-150 Hz symmetrical rail || 1 mm 5-13.2 Hz panel mounting || 0.7 gn 13.2-100 Hz panel mounting
- Ambient Air Temperature For Storage
- -25-70 °C
- Relative Humidity
- 10-95 %, without condensation in operation) || 10-95 %, without condensation in storage)
- Ip Degree Of Protection
- IP20 with protective cover in place
- Resistance To Electrostatic Discharge
- 8 kV in air IEC 61000-4-2 || 4 kV on contact IEC 61000-4-2 || 8 kV in air Marine specification (LR, ABS, DNV, GL) || 6 kV on contact Marine specification (LR, ABS, DNV, GL)
- Resistance To Fast Transients
- 2 kV IEC 61000-4-4 power lines) || 2 kV IEC 61000-4-4 relay output) || 1.5 kV IEC 61000-4-4 I/O) || 1 kV IEC 61000-4-4 Ethernet line) || 1 kV IEC 61000-4-4 serial link)
- Operating Altitude
- 0...6561.68 ft (0...2000 m)
- Electromagnetic Emission
- conducted emissions 79 dBμV/m QP/66 dBμV/m AV power lines (AC))0.15-0.5 MHz IEC 55011 || conducted emissions 73 dBμV/m QP/60 dBμV/m AV power lines (AC))0.5-300 MHz IEC 55011 || conducted emissions 120...69 dBµV/m QP power lines)10-150 kHz IEC 55011 || conducted emissions 63 dBμV/m QP power lines)1.5-30 MHz IEC 55011 || radiated emissions 40 dBμV/m QP class A30-230 MHz IEC 55011 || radiated emissions 60...54 dBμV/m QP30-100 MHz Marine specification (LR, ABS, DNV, GL) || radiated emissions 24 dBμV/m QP156-165 MHz Marine specification (LR, ABS, DNV, GL) || conducted emissions 79...63 dBμV/m QP power lines)150-1500 kHz IEC 55011 || radiated emissions 47 dBμV/m QP class A230-1000 MHz IEC 55011 || radiated emissions 80...50 dμV/m QP150-30000 kHz Marine specification (LR, ABS, DNV, GL) || radiated emissions 54 dBμV/m QP100-2000 MHz Marine specification (LR, ABS, DNV, GL)
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP1403009EN
- Sustainable Offer Status
- Green Premium product
- Pvc Free
- Yes
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation
- X
- Circularity Profile
- ENVEOLI1403009EN
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
Specifications
- Product Or Component Type
- Profibus DP communication module
Documents
Data Sheet
DownloadCAD Models
traceparts
Download