Guard switch, Telemecanique Safety switches XCS, XCSTR, spindle 30 mm, 1NC+2 NO, Pg11
XCSTR551
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Offer with manufacturer lead time
Ships in:1 - 2 business days
Best price:
Send request for price

Additional Information

Part Number
XCSTR551
UNSPSC
39122205
Tariff Code
8536509025
Country of Origin
FR

Specifications

Contacts Type And Composition
1 NC + 1 NO + 1 NO
Range Of Product
Telemecanique Safety switches XCS
Insulation
double insulated
Cable Entry
2 entries tapped Pg 11
Clamping Connection Capacity
1 x 0.34...2 x 0.75 mm² with or without cable end
Contact Operation
slow-break, break before make
Type Of Operator
spindle 30 mm
Electrical Connection
terminal
Product Or Component Type
guard switch
Component Name
XCSTR
Material
plastic
Number Of Poles
3
Head Type
turret head rotary axis

Contractual warranty

Warranty
18 months

Complementary

Height
117-117 mm
[Ui] Rated Insulation Voltage
300 VUL 508 || 300 VCSA C22.2 No 14 || 400 V 3)EN/IEC 60947-1
Short-Circuit Protection
6 A cartridge fuse gG (gl)
Positive Opening
with NC contact
Minimum Actuation Speed
0.1 m/s
Positive Opening Minimum Torque
0.45 N.m
Mechanical Durability
1000000 cycles
[Ithe] Conventional Enclosed Thermal Current
6 A
Safety Reliability Data
B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
Enclosure Material
polyamide PA66 fibre glass impregnated
Lever Material
stainless steel
Contact Code Designation
B300, AC-15 (Ue = 120 V, Ie = 6 A)EN/IEC 60947-5-1 || B300, AC-15 (Ue = 240 V, Ie = 3 A)EN/IEC 60947-5-1 || Q300, DC-13 (Ue = 125 V, Ie = 0.2 A)EN/IEC 60947-5-1 || R300, DC-13 (Ue = 250 V, Ie = 0.1 A)EN/IEC 60947-5-1
Tripping Angle
5 °
Width
52 mm
Depth
60 mm
Cable Outer Diameter
7-10 mm
Minimum Torque For Tripping
0.1 N.m
Net Weight
0.155 kg
[Uimp] Rated Impulse Withstand Voltage
4 kV EN/IEC 60947-5-1
Maximum Resistance Across Terminals
30 mOhm EN/IEC 60947-5-4
Safety Level
can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired IEC 61508

Offer Sustainability

Circularity Profile
ENVEOLI110603EN
Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP110606EN
Sustainable Offer Status
Green Premium product
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Environment

Product Certifications
CSA || BG || UL
Ambient Air Temperature For Operation
-25-70 °C
Ambient Air Temperature For Storage
-40-70 °C
Standards
EN/IEC 60204-1 || EN 1088/ISO 14119 || UL 508 || CSA C22.2 No 14 || EN/IEC 60947-5-1 || EN/IEC 60947-5-4 || EN/ISO 12100
Electrical Shock Protection Class
class II EN/IEC 61140
Shock Resistance
50 gn 11 ms IEC 60068-2-27
Vibration Resistance
50 gn 10-500 Hz)IEC 60068-2-6
Protective Treatment
TH || TC
Ip Degree Of Protection
IP67 conforming to IEC 60529

Documents

Data Sheet

Download

Related products