ABB

A110-30-22-83

1 / 1
thumbnail

Description

A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 1000 V.Operated with control voltage, versions from 24….690 AC, 50 and 60 Hz
Part Number
A110-30-22-83
UNSPSC
39121529
ETIM
Group Code : EG000017
Group Description : Low-voltage Industrial Components
Class Description : Power contactor, AC switching
Class Code : EC000066
Version : 7
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Dimensions

Product Net Width
90 mm
Product Net Depth / Length
156.5 mm
Product Net Height
148 mm
Product Net Weight
1.8 kg

Technical

Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 160 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 160 A(690 V) 55 °C 145 A(690 V) 70 °C 130 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 110 A(440 V) 55 °C 100 A(500 V) 55 °C 100 A(690 V) 55 °C 82 A(1000 V) 55 °C 30 A(380 / 400 V) 55 °C 110 A(220 / 230 / 240 V) 55 °C 110
Rated Operational Power AC-3 (Pe)
(415 V) 59 kW(440 V) 59 kW(500 V) 59 kW(690 V) 75 kW(1000 V) 40 kW(380 / 400 V) 55 kW(220 / 230 / 240 V) 30 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Short-Circuit Protective Devices
gG Type Fuses 200 A
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 800 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 175 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 350 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1320 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 500 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour(AC-2 / AC-4) 150 cycles per hour(AC-3) 300 cycles per hour
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 160 A(220 V) 3 Poles in Series, 40 °C 160 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 160 A(220 V) 3 Poles in Series, 40 °C 160 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 160 A(220 V) 3 Poles in Series, 40 °C 160 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 Vacc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Mechanical Durability
10 million
Maximum Mechanical Switching Frequency
3600 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 48 V60 Hz 48 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 22 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 26 V·APull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 450 V·A
Operate Time
Between Coil De-energization and NC Contact Closing 7 ... 15 msBetween Coil De-energization and NO Contact Opening 10 ... 18 msBetween Coil Energization and NC Contact Opening 7 ... 22 msBetween Coil Energization and NO Contact Closing 10 ... 25 ms
Connecting Capacity Main Circuit
Bar 30 mm²Flexible with Cable End 1 x 10 ... 70 mm²Rigid 2 x 6 ... 65 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²Flexible 1x0.75 ... 2.5 mm²Solid 1 x 1 ... 4 mm²Stranded 2 x 1 .... 4 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Connecting Terminals (delivered in open position) Main Poles
M8 hexagon socket screw with single connector
Terminal Type
Cable Clamp

Classifications

Object Classification Code
Q
ETIM 4
EC000066 - Magnet contactor, AC-switching
ETIM 5
EC000066 - Magnet contactor, AC-switching
EClass
V11.0 : 27371003
IDEA Granular Category Code (IGCC)
4755 >> Contactors

Environmental

Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °CClose to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °CClose to Contactor for Storage -60 ... +80 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: A 20 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: A 20 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: B1 15 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C1 20 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C2 20 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B1 5 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B2 15 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C1 20 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C2 20 g
RoHS Status
Following EU Directive 2011/65/EU

Technical UL/CSA

Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 140 A
Horsepower Rating UL/CSA
(200 V AC) Three Phase 30 hp(208 V AC) Three Phase 30 hp(220 ... 240 V AC) Three Phase 40 hp(440 ... 480 V AC) Three Phase 75 hp(550 ... 600 V AC) Three Phase 100 hp

Ordering

Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Replacement Product ID (NEW)
1SFL427001R1122